HCNW136-500E Avago Technologies US Inc., HCNW136-500E Datasheet - Page 8

OPTOCOUPLER 1CH 1MBS 8-SMD

HCNW136-500E

Manufacturer Part Number
HCNW136-500E
Description
OPTOCOUPLER 1CH 1MBS 8-SMD
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCNW136-500E

Voltage - Isolation
5000Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
8mA
Data Rate
1Mbps
Propagation Delay High - Low @ If
200ns @ 16mA
Current - Dc Forward (if)
25mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount, Gull Wing
Package / Case
8-SMD (400 mil) Gull Wing
No. Of Channels
1
Optocoupler Output Type
Phototransistor
Input Current
16mA
Output Voltage
20V
Opto Case Style
SMD
No. Of Pins
8
Isolation Voltage
5kV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCNW136-500E
Manufacturer:
AVAGO
Quantity:
8 290
Part Number:
HCNW136-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (OPTION 060 ONLY)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCNW135/6 ONLY)
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
8
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
(Transient Overvoltage, t
Safety Limiting Values
Insulation Resistance at T
for rated mains voltage ≤300 V rms
for rated mains voltage ≤450 V rms
V
Partial Discharge < 5 pC
V
t
(Maximum values allowed in the event of a failure,
also see Figure 9, Thermal Derating curve.)
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
V
Partial Discharge < 5 pC
V
t
(Maximum values allowed in the event of a failure,
also see Figure 9, Thermal Derating curve.)
m
m
IORM
IORM
IORM
IORM
Case Temperature
Input Current
Output Power
= 60 sec, Partial Discharge < 5 pC
Case Temperature
Input Current
Output Power
= 60 sec, Partial Discharge < 5 pC
x 1.875 = V
x 1.5 = V
x 1.875 = V
x 1.5 = V
PR
PR
, Type and sample test,
, Type and sample test,
PR
PR
, 100% Production Test with t
, 100% Production Test with t
ini
ini
S
S
, V
, V
= 10 sec)
= 10 sec)
IO
IO
= 500 V
= 500 V
Description
m
m
= 1 sec,
= 1 sec,
P
Symbol
I
S,OUTPUT
V
V
S,INPUT
V
V
IORM
R
IOTM
T
PR
PR
S
S
55/100/21
8 Pin DIP
P
Symbol
I
1181
6000
≥ 10
S,OUTPUT
V
V
S,INPUT
630
945
175
230
600
I-III
I-IV
V
V
IORM
R
IOTM
T
2
PR
PR
S
S
9
Characteristic
Characteristic
55/100/21
55/85/21
≥ 10
1414
2652
2121
8000
≥ 10
1050
4000
SO-8
150
400
700
560
840
175
150
600
I-III
I-III
I-IV
2
2
9
9
Units
Units
V
V
V
V
V
V
V
V
mW
mW
mA
mA
°C
°C
peak
peak
peak
peak
peak
peak
peak
peak

Related parts for HCNW136-500E