HCPL-3180-060E Avago Technologies US Inc., HCPL-3180-060E Datasheet - Page 4

no-image

HCPL-3180-060E

Manufacturer Part Number
HCPL-3180-060E
Description
OPTOCOUPLER DRVR 2.5A VDE 8-DIP
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-3180-060E

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
2.5A
Propagation Delay High - Low @ If
150ns @ 10mA
Current - Dc Forward (if)
16mA
Input Type
DC
Output Type
Gate Driver
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
No. Of Channels
1
Optocoupler Output Type
Gate Drive
Input Current
16mA
Output Voltage
20V
Opto Case Style
DIP
No. Of Pins
8
Propagation Delay Low-high
0.2µs
Isolation Voltage
3.75kV
Common Mode Ratio
10 KV/uS
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-3180-060E
Manufacturer:
AVAGO
Quantity:
10 000
Part Number:
HCPL-3180-060E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Recommended Pb-Free IR Profile
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (HCPL-3180 Option 060)
Description
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section IEC/
** Refer to the following figure for dependence of P
4
Partial Discharge < 5 pC
Installation classification per DIN EN 0110 1997-04
for rated mains voltage ≤ 150 V
for rated mains voltage ≤ 300 V
for rated mains voltage ≤ 600 V
Climatic Classification
Pollution Degree (DIN EN 0110 1997-04)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
t
Input to Output Test Voltage, Method a*
V
Highest Allowable Overvoltage
(Transient Overvoltage t
Safety-limiting values – maximum values allowed in the
event of a failure.
Case Temperature
Input Current**
Output Power**
Insulation Resistance at T
Note: Non-halide flux should be used.
NOTES:
THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX.
T
m
EN/DIN EN 60747-5-2 for a detailed description of Method a and Method b partial discharge test profiles.
IORM
IORM
smax
T
=1 sec, Partial Discharge < 5 pC
T
smax
smin
25
T
T
= 200 °C, T
p
L
x 1.875=V
x 1.5=V
217 °C
150 - 200 °C
smin
PR
t 25 °C to PEAK
, Type and Sample Test, t
PR
60 to 180 SEC.
3 °C/SEC. MAX.
= 150 °C
PREHEAT
, 100% Production Test with
t
RAMP-UP
s
260 +0/-5 °C
ini
S
, V
= 10 sec)
TIME
IO
= 500 V
rms
rms
rms
t
t
L
p
m
=60 sec,
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
20-40 SEC.
60 to 150 SEC.
S
RAMP-DOWN
6 °C/SEC. MAX.
and I
S
on ambient temperature.
Regulatory Information
The HCPL-3180 has been approved by the following
organizations:
IEC/EN/DIN EN 60747-5-2
Approved under: IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01
(Option 060 only)
UL
Approval under UL 1577, component recognition
program up to V
CSA
Approval under CSA Component Acceptance Notice #5,
File CA 88324.
P
S, OUTPUT
I
Symbol
V
S,INPUT
V
V
V
IORM
IOTM
T
R
PR
PR
S
S
ISO
= 3750 V
55/100/21
HCPL-3180
rms
1181
6000
>10
I - IV
I - III
630
945
175
230
600
I-II
2
. File E55361.
9
V
V
V
V
mW
Unit
mA
peak
peak
peak
peak
°C

Related parts for HCPL-3180-060E