SMART500RT1U Tripp Lite, SMART500RT1U Datasheet - Page 3

UPS 500VA 300W 6OUT W/SOFTWARE

SMART500RT1U

Manufacturer Part Number
SMART500RT1U
Description
UPS 500VA 300W 6OUT W/SOFTWARE
Manufacturer
Tripp Lite
Series
Smart Pro®r
Type
Power Supply Regulatorr
Datasheets

Specifications of SMART500RT1U

Rohs Status
Not applicable
Power - Rated
500VA / 300W
Ac Outlets
6 (UPS)
Features
DB9 and USB Communications, SNMP Card Slot
Backup Time - Max Load
5 minutes
Voltage - Output Per Connector
120V
Voltage - Input
120V / 15A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA 5-15P
Connector - Ac Output
NEMA 5-15R
Size
11.75" L x 17.50" W x 1.75" H (298.5mm x 444.5mm x 44.5mm)
Weight
18 lbs (8.2kg)
Ac Output Connector
NEMA 5-15R
Brand/series
SmartPro®
Capacity
500 VA
Color
Black
Communication
DB9, RJ11, USB
Current, Rating
5.6 A (Max.)
Dimensions
4.45cmH×44.5cmW×29.8cmD
Frequency, Output
60 Hz
Input Type
NEMA 5-15P
Length, Cord
10 ft.
Mounting Type
Rack/Tower
Operation
Line-Interactive
Output Type
(7) NEMA 5-15R
Power, Rating
300 W
Standards
cUL, UL Listed
Temperature, Operating
0 to +40 °C
Time, Backup
3 min.
Voltage Regulation
120 V (PWM Sine Wave) Output within 10% @ Battery Mode
Voltage, Battery
12 VDC
Voltage, Input
120 V
Voltage, Nominal
120 VAC (Output)
Voltage, Output
120 VAC
Voltage, Supply
300/500 W/VA
Media Lines Protected
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
TL309
Output AC waveform
(battery mode)
INPUT
Rated input current (at
maximum load)
Nominal Input Voltage(s)
Supported
UPS input connection type
Input circuit breaker
UPS Input cord length (ft.)
UPS Input cord length (m)
Recommended Electrical
Service
BATTERY
Full load runtime (minutes)
Half load runtime
(minutes)
DC system voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery Access
Battery replacement
description
VOLTAGE REGULATION
Voltage regulation
description
Undervoltage correction
LEDS ALARMS & SWITCHES
LED Indicators
Alarms
Alarm cancel operation
Switches
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
EMI / RFI AC noise
suppression
AC suppression joule
rating
PWM sine wave
5.6A
120V AC
5-15P
15A
10
4.5
15A 120V
3 min. (300w)
8 min. (150w)
12
Less than 4 hours from 10% to 90%
RBC62-1U
Battery access door
Hot-swappable, user replaceable batteries
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90
Input voltages between 90 and 108 are boosted by 14%
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
Audible alarm indicates power-failure, overload and low-battery conditions
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
2 Switches control off/on power status and alarm-cancel/self-test operation
510 joules
Yes
510