DMF-5010NBU-FW-BD Optrex America Inc, DMF-5010NBU-FW-BD Datasheet

no-image

DMF-5010NBU-FW-BD

Manufacturer Part Number
DMF-5010NBU-FW-BD
Description
LCD GRAPHIC MODULE 240X64 PIXEL
Manufacturer
Optrex America Inc
Series
DMF-5010r
Datasheet

Specifications of DMF-5010NBU-FW-BD

Display Type
LCD - Monochrome
Display Mode
Transflective
Viewing Area
132.00mm L x 39.00mm W
Backlight
CCFL - White
Dot Size
0.49mm W x 0.49mm H
Dot Pitch
0.53mm x 0.53mm
Dot Pixels
240 x 64
Interface
Parallel
Other names
73-1132
DMF-5010NBU-FW
DMF5010NBU-FW
DMF5010NBUFW
OP150NBUFW
Type No.
Rev.
DMF5010NBU-FW (AB) No.2000-00153
LCD Module Specification
DMF5010NBU−FW
Date
10. Precautions Relating Product Handling....................................................... 18
11. Warranty.............................................................................................................. 19
1. General Specifications ........................................................................................ 2
2. Electrical Specifications...................................................................................... 3
3. Optical Specifications......................................................................................... 8
4. I/O Terminal........................................................................................................ 10
5. Test....................................................................................................................... 13
6. Appearance Standards..................................................................................... 14
7. Code System of Production Lot................................................................... 17
8. Type Number...................................................................................................... 17
9. Applying Precautions....................................................................................... 17
Page
Table of Contents
Revision History
OPTREX
Apr 18, 2000
Final Revision
First Edition
*******
OPTREX CORPORATION
Comment
Approved by
Checked by
Checked by
Prepared by
Design Engineering Div.
Quality Assurance Div.
Page 1/19
Production Div.
Production Div.

Related parts for DMF-5010NBU-FW-BD

DMF-5010NBU-FW-BD Summary of contents

Page 1

... I/O Terminal........................................................................................................ 10 5. Test....................................................................................................................... 13 6. Appearance Standards..................................................................................... 14 7. Code System of Production Lot................................................................... 17 8. Type Number...................................................................................................... 17 9. Applying Precautions....................................................................................... 17 10. Precautions Relating Product Handling....................................................... 18 11. Warranty.............................................................................................................. 19 Rev. Date DMF5010NBU-FW (AB) No.2000-00153 First Edition Apr 18, 2000 Final Revision ******* Table of Contents Revision History Page OPTREX CORPORATION OPTREX Approved by Production Div ...

Page 2

... Cold Cathode Fluorescent Lamp (CFL) × 1 Backlight : Holder and PWB ground are connected by soldering. Additional Spec. CFL light unit is replaceable. : Dimensional Outline Drawings DMF5010NBU-FW (AB) No.2000-00153 * (W) × 81.0 (H) × 23.0 max. ( Without CFL Cable ( STN / Blue-mode / Transmissive ) UE-32421C OPTREX CORPORATION ...

Page 3

... V IH Input Voltage Low Level V IL Input Voltage High Level V OH Output Voltage Low Level V OL Output Voltage I CC Supply Current I EE DMF5010NBU-FW (AB) No.2000-00153 Conditions Min. − -0.3 − 0 − -0.3 Conditions Min. − 4.5 Shown in 3.1 =5.0V ± =5.0V ± 10% ...

Page 4

... Characteristics Parameter C/D Setup Time C/D Hold Time CE, RD, WR Pulse Width Data Setup Time Data Hold Time Access Time Output Hold Time C ∼ D7 (WRITE) D0 ∼ D7 (READ) DMF5010NBU-FW (AB) No.2000-00153 Symbol Min. t 100 CDS t 10 CDH − ACC CDS ACC ...

Page 5

... Please maintain the above sequence when turning on and off the power supply of the module supplied to the module while internal alternate signal for LCD driving (M) is unstable or EE RESET is active, DC component will be supplied to the LCD panel. This may cause damage to the LCD module. DMF5010NBU-FW (AB) No.2000-00153 0≦t 0 ≦ ≦ ≦ t T≧ ≧ ...

Page 6

... DMF5010NBU-FW (AB) No.2000-00153 OPTREX CORPORATION OPTREX Page 6/19 ...

Page 7

... Average Life representes the time elapsed at the point of time when the residual ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life mentioned above Recommended Inverter : HIU-32 ( Produced by HARISON ) CXA-L10L (DC 12.0V, Produced by TDK) DMF5010NBU-FW (AB) No.2000-00153 Conditions Min. Typ. − − 270 − ...

Page 8

... Duty - 1/B Bias ( A : Duty Number Bias Number ). Driving voltage V the voltage V when the contrast ratio (CR=L O-P V O-P × 〈 ON SIGNAL 〉 DMF5010NBU-FW (AB) No.2000-00153 Conditions Ta= 10 ℃ Ta=25 ℃ Ta=40 ℃ Ta=25 ℃ , 1/64 Duty, 1/9 Bias, V Conditions θ ゚ , φ = −゚ ...

Page 9

... Driving condition : 1/64 Duty, 1/9 Bias ゚ 135 ゚ 180 ゚ 225 ゚ 270 ゚ ・ Area shows typ. CR ≧ 2 3.4.System Block Diagram Photometer #1980A WB Computer DMF5010NBU-FW (AB) No.2000-00153 f =12.9V, =70Hz ゚ φ ( φ ゚) θ 180 ゚ 315 ゚ 270 ゚ ...

Page 10

... CN2 No. Symbol 1 CFL (HOT CFL (GND) DMF5010NBU-FW (AB) No.2000-00153 Level − Frame Ground ― Power Supply (0V, GND) ― Power Supply for Logic ― Power Supply for LCD Drive Write Signal L : Active Read Signal L : Active Chip Enable Signal L : Active Write Mode H : Command Write L : Data Write Read Mode H : Status Read L : Data Read − ...

Page 11

... 4.3.Block Diagram 8 D0 ∼ Control LSI CE T6963C C/D RESET FS X-tal 64K S-RAM VCC VSS J FG VEE CFL(HOT) CFL(GND) DMF5010NBU-FW (AB) No.2000-00153 VCC (+Voltage VEE (-Voltage VSS (0V ∼ Ω Tr=2SA1202 or equivalent Row Driver T6961B × equivalent Bias Circuit ...

Page 12

... DMF5010NBU-FW (AB) No.2000-00153 OPTREX CORPORATION OPTREX Page 12/19 ...

Page 13

... Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity after removed from the test chamber. Note 5 : Vibration test will be conducted to the product itself without putting container. DMF5010NBU-FW (AB) No.2000-00153 Conditions 40 ℃± 2 ℃ , 96hrs (operation state) 10 ℃± 2 ℃ , 96hrs (operation state) 60 ℃ ...

Page 14

... All directions for inspecting the sample should be within 45 ゚ against perpendicular line. 6.2.Definition of applicable Zones A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area DMF5010NBU-FW (AB) No.2000-00153 45 ゚ A Zone Bezel Flame B Zone C Zone ...

Page 15

... No. Parameter 1 Black and White Spots, Foreign Substances 2 Air Bubbles (between glass & polarizer) DMF5010NBU-FW (AB) No.2000-00153 Criteria (1) Round Shape Zone Dimension (mm) D ≦ 0.1 0.1 < D ≦ 0.2 0.2 < D ≦ 0.25 0.25 < D ≦ 0.3 0.3 < Long + Short ) / Disregard ...

Page 16

... The Shape of Dot 4 Polarizer Scratches 5 Polarizer Dirts 6 Complex Foreign Substance Defects 7 Distance between Different Foreign Substance Defects DMF5010NBU-FW (AB) No.2000-00153 Criteria (1) Dot Shape (with Dent) 0.15 ≧ (2) Dot Shape (with Projection) (3) Pin Hole X Y (4) Deformation Y X Total acceptable number : 1/dot, 5/cell (Defect number of (4) : 1pc.) Not to be conspicuous defects ...

Page 17

... The type number of module is specified on the back of module as follows. DMF5010 NBU−FW Etching or Printing 9.Applying Precautions Please contact us when questions and/or new problems not specified in this specifications arise. DMF5010NBU-FW (AB) No.2000-00153 □ □ Factory Number (Numeral) Factory Code (Alphabet) Production Week (1 ∼ ...

Page 18

... Care should be taken not to touch connection areas to avoid burns. ② Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. ③ The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life. DMF5010NBU-FW (AB) No.2000-00153 OPTREX CORPORATION OPTREX Page 18/19 ...

Page 19

... Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later. DMF5010NBU-FW (AB) No.2000-00153 OPTREX CORPORATION OPTREX ...

Related keywords