VK202-25 Matrix Orbital, VK202-25 Datasheet - Page 30

VFD ALPHA/NUM DISPL 20X2 SER/I2C

VK202-25

Manufacturer Part Number
VK202-25
Description
VFD ALPHA/NUM DISPL 20X2 SER/I2C
Manufacturer
Matrix Orbital
Series
VK202-25r
Datasheet

Specifications of VK202-25

Outline L X W X H
116.00mm x 37.00mm x 29.48mm
Viewing Area
89.75mm L x 11.50mm W
Display Format
20 x 2
Display Type
Character
Format
5 x 7 Dots
Character Size
4.70mm H x 2.40mm W
Interface
Serial
Operating Temperature
-20°C ~ 70°C
Product
Character Display Modules
Character Count X Line
20 x 2
Module Size (w X H X T)
116 mm x 37 mm x 29.48 mm
Operating Temperature Range
- 20 C to + 70 C
Dot Format
5 x 7
Viewing Area (w X H)
89.75 mm x 11.5 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Number Of Dots
-
Lead Free Status / Rohs Status
 Details
Other names
635-1020
7.7 Miscellaneous Commands
Table 7-4 Miscellaneous Commands
VK202-25 rev. 05
Command
Clear display
Set brightness
Display on
Display off
Load startup screen
General purpose
output off
General purpose
output on
Set I
Read module type
Set RS232 port
speed
Set Serial Number
Read Serial Number
Read Version
Number
Enter flow control
mode
2
C address
Syntax
FE 58
254 88
254 'X'
FE 59 [brightness]
254 89 [brightness]
254 'Y' [brightness]
FE 42 [minutes]
254 66 [minutes]
254 'B' [minutes]
FE 46
254 70
254 'F'
FE 40 [40 char]
254 64 [40 char]
254 '@' [40 char]
FE 56 [gpo #]
254 86 [gpo #]
254 'V' [gpo #]
FE 57 [gpo #]
254 87 [gpo #]
254 'W' [gpo #]
FE 33 [address]
254 51 [address]
254 '3' [address]
FE 37
254 55
254 '7'
FE 39 [speed]
254 57 [speed]
254 '9' [speed]
FE 34 [byte1][byte2]
254 52
[byte1][byte2]
254 '4' [byte1][byte2]
FE 35
254 53
254 '5'
FE 36
254 54
254 '6'
FE 3A [full] [empty]
254 58 [full] [empty]
Default
n/a
0x03
100%
on
on
off
off
0x50
see table
19,200 baud
off
Matrix Orbital
VK202-25
30
Notes
Clears screen of text and graphics, places text
cursor at top left.
Sets display brightness. Brightness is a value
between 0x00 and 0x03. 0x00=25%,
0x01=50%, 0x02=75%, 0x03=100%.
Display will stay on for [minutes]. If [minutes] =
0 display will stay on permanently. Maximum
value for [minutes] is 100.
Turns off display.
Loads new startup screen (40 characters).
Screen is saved for subsequent power ups.
Turns a general purpose output OFF. [gpo #]
may be from 1 to 6. See section 2.2 for further
details.
Turns a general purpose output ON. [gpo #]
may be from 1 to 6. See section 2.2 for further
details.
Value is write address and must be even, read
address is 1 higher.
Reads the module type. See table in section
6.1.9. This will return a 1 byte hex value.
Sets RS232 speed. See table in section
6.1.10 for values of [speed]
This is a one-time-use command which works
only on units without factory set serial
numbers.
Reads the two byte serial number of the
module.
Reads the firmware version number of the
module. This will return a 1 byte hex value.
Sets "full" and "empty" marks for the 80 byte
display buffer. When buffer reaches [full]

Related parts for VK202-25