LW G6SP-EAFA-JKQL-1-Z OSRAM Opto Semiconductors Inc, LW G6SP-EAFA-JKQL-1-Z Datasheet

no-image

LW G6SP-EAFA-JKQL-1-Z

Manufacturer Part Number
LW G6SP-EAFA-JKQL-1-Z
Description
LED TOPLED ADV PWR WHT 6PLCC
Manufacturer
OSRAM Opto Semiconductors Inc
Series
TOPLEDr
Datasheet

Specifications of LW G6SP-EAFA-JKQL-1-Z

Color
White, Cool
Current - Test
140mA
Luminous Flux @ Current - Test
32lm
Current - Max
250mA
Lumens @ Current - Max
43lm
Lumens/watt @ Current - Test
63lm/W
Voltage - Forward (vf) Typ
3.6V
Wavelength
5600K
Lens Style/size
Round, 2.6mm
Viewing Angle
120°
Mounting Type
Surface Mount
Package / Case
6-LCC (J-Lead)
Power Rating
1075 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q65110A9043
Advanced Power TOPLED
Enhanced optical Power LED (ThinGaN)
Lead (Pb) Free Product - RoHS Compliant
LW G6SP
Released
OS-IN-2009-009
Besondere Merkmale
• Gehäusetyp: weißes P-LCC-6 Gehäuse,
• Besonderheit des Bauteils: sehr kleiner
• Farbort: x = 0,33, y = 0,33 nach
• typische Farbtemperatur: 5600 K
• Farbwiedergabeindex: 80
• Abstrahlwinkel: Lambertscher Strahler (120°)
• Technologie: ThinGaN
• optischer Wirkungsgrad: 44 lm/W
• Gruppierungsparameter: Lichtstärke,
• Verarbeitungsmethode: für alle
• Lötmethode: Reflow Löten
• Vorbehandlung: nach JEDEC Level 2
• Gurtung: 12 mm Gurt mit 1000/Rolle,
• ESD-Festigkeit: ESD-sicher bis 2 kV nach
Anwendungen
• Innenbeleuchtung im Automobilbereich (z.B.
• Hinterleuchtung (Werbebeleuchtung,
• Leselampen (Flugzeug, Auto, Bus)
• Ersatz von Kleinst-Glühlampen
• Display Hinterleuchtung mit hohem
• Dekorative Beleuchtung
• Signal- und Symbolleuchten zur Orientierung
• Markierungsbeleuchtung (z.B. Stufen, Flucht-
2009-07-21
farbiger diffuser Silikon - Verguss
thermischer Widerstand, dadurch sehr hohe
Lichtleistung möglich
CIE 1931 (weiß)
Farbort, Durchlassspannung
SMT-Bestücktechniken geeignet
ø180 mm
JESD22-A114-D
Instrumentenbeleuchtung)
Allgemeinbeleuchtung)
Helligkeitsbedarf z. B. TFT
wege, u.ä.)
1
Features
• package: white P-LCC-6 package, colored
• feature of the device: very low thermal
• color coordinates: x = 0.33, y = 0.33 acc. to
• typ. color temperature: 5600 K
• color reproduction index: 80
• viewing angle: Lambertian Emitter (120°)
• technology: ThinGaN
• optical efficiency: 44 lm/W
• grouping parameter: luminous intensity,
• assembly methods: suitable for all
• soldering methods: reflow soldering
• preconditioning: acc. to JEDEC Level 2
• taping: 12 mm tape with 1000/reel, ø180 mm
• ESD-withstand voltage: up to 2 kV acc. to
Applications
• interior automotive lighting (e.g. dashboard
• backlighting (illuminated advertising, general
• reading lamps (aircraft, car, bus)
• substitution of micro incandescent lamps
• display backlight where high brightness is
• decorative and entertainment lighting
• signal and symbol luminaire for orientation
• marker lights (e.g. steps, exit ways, etc.)
diffused silicone resin
resistance; high optical power
CIE 1931 (white)
color coordinates, forward voltage
SMT assembly methods
JESD22-A114-D
backlighting)
lighting)
required e.g. TFT

Related parts for LW G6SP-EAFA-JKQL-1-Z

LW G6SP-EAFA-JKQL-1-Z Summary of contents

Page 1

... Advanced Power TOPLED Enhanced optical Power LED (ThinGaN) Lead (Pb) Free Product - RoHS Compliant LW G6SP Released OS-IN-2009-009 Besondere Merkmale • Gehäusetyp: weißes P-LCC-6 Gehäuse, farbiger diffuser Silikon - Verguss • Besonderheit des Bauteils: sehr kleiner thermischer Widerstand, dadurch sehr hohe Lichtleistung mö ...

Page 2

... Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 7 für nähere Informationen). Es wird nur eine einzige Helligkeitsgruppe pro Gurt geliefert. Z.B.: LW G6SP-EAFA-JKQL-1 bedeutet, dass auf dem Gurt nur eine der Helligkeitsgruppen EA, EB oder FA enthalten ist. ...

Page 3

... Symbol Wert Symbol Value T – 40 … + 110 op T – 40 … + 110 stg T >150 for short j term applications T + 125 j (min (max.) 250 F I 750 FM V not designed for R reverse operation P 1075 tot G6SP Einheit Unit °C °C °C ° K/W K/W ...

Page 4

... F V (max.) F (typ (max (typ.) TC (typ.) TC (typ η (typ.) opt 4 Wert Value 0.33* 0.33* 120 2.9* 3.6 4.1 not designed for reverse operation see page 9 x see page 9 y –4 G6SP Einheit Unit – – Grad deg μ A μ mV/K lm/W ...

Page 5

... 0.27 JK 0.25 0.23 0.21 0.19 Cx 0,3288 0,3288 0,3386 0,3386 0,3288 0,3288 0,3386 0,3386 0,3386 0,3386 0,3484 0,3484 0,3386 0,3386 0,3484 0,3484 LW G6SP OHL04146 Cy 0,3081 0,3282 0,3426 0,3235 0,3282 0,3453 0,3591 0,3426 0,3235 0,3426 0,3571 0,3388 0,3426 0,3591 0,373 0,3571 ...

Page 6

... Cy Group 0,297 PK 0,3131 0,2956 0,284 0,312 PL 0,3302 0,3131 0,297 0,3131 QK 0,3282 0,3081 0,2956 0,3302 QL 0,3452 0,3282 0,3131 6 LW G6SP Cx Cy 0,3484 0,3388 0,3484 0,3571 0,3582 0,3715 0,3582 0,3542 0,3484 0,3571 0,3484 0,373 0,3582 0,3792 0,3582 0,3715 0,3582 0,3542 0,3582 0,3715 0,368 ...

Page 7

... Luminous Intensity I (mcd) V 7100 ... 9000 9000 ... 11200 11200 ... 14000 6) Seite 18 Durchlassspannung Forward voltage max. 3.2 3.5 3.8 4.1 Farbortgruppe Chromaticity Coordinate Group G6SP 2) Seite 18 Lichtstrom 2) page 18 Luminous Flux Φ (mlm) V 24000 (typ.) 30300 (typ.) 37800 (typ.) Einheit Unit Durchlassspannungsgruppe Forward Voltage Group 5 ...

Page 8

... Seite 18 2) page 18 500 550 20˚ 10˚ 0˚ ϕ 1.0 0.8 0.6 0.4 0.2 0 0.6 0.4 0˚ λ 600 650 700 20˚ 40˚ 60˚ 80˚ LW G6SP OHL02380 nm 750 λ OHL01660 100˚ 120˚ ...

Page 9

... Seite 18 Farbortverschiebung Chromaticity Coordinate Shift ° 0.015 Cx, Cy 0.005 0 -0.005 -0.010 -0.015 -0.020 -0.025 0 100 200 2009-07-21 Relative Lichtstrom Relative Luminous Flux Ι / Ι V OHL02767 4.2 4 page 18 OHL02770 Cx Cy 300 400 mA 500 Seite page 18 (140 mA ° (140 mA G6SP OHL02768 ...

Page 10

... Seite 18 Relative Lichtstärke Relative Luminous Intensity ); I = 140 OHL02772 40 60 ˚C 100 page 18 OHL02782 ˚C 100 Seite 18 I (25 ° 140 1 (25 ˚C) 1.0 0.8 0.6 0.4 0.2 0 -60 -40 - G6SP 2) page 18 OHL02725 40 60 ˚C 100 T j ...

Page 11

... parameter ° 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0. G6SP 2) Seite 17 Einheit Unit Betriebsstunden operating hours Betriebsstunden operating hours Betriebsstunden operating hours Betriebsstunden operating hours OHL02780 0.005 0.01 0.02 0.05 0.1 0.2 0 ...

Page 12

... Seite 18 Maßzeichnung 8) page 18 Package Outlines Kathodenkennung: Cathode mark: Gewicht / Approx. weight: Gurtung / Polarität und Lage Method of Taping / Polarity and Orientation 2009-07-21 Markierung mark Seite 18 Verpackungseinheit 1000/Rolle, ø180 mm 8) page 18 Packing unit 1000/reel, ø180 G6SP ...

Page 13

... Anm.: Das Gehäuse ist für Ultraschallreinigung nicht geeignet Note: Package not suitalbe for ultra sonic cleaning 2009-07- Seite page 18 0.8 (0.031) 2 0.35 (0.014) 0.6 (0.024) Lötstopplack Solder resist 13 Reflow Löten Reflow Soldering 0.8 (0.031) 0.35 (0.014) OHLP4927 LW G6SP Package marking ...

Page 14

... B) OHLA0687 260 ˚C 245 ˚C 235 ˚ min 30 s max Ramp Down 6 K/s (max) 100 s max 200 250 s t Normalkurve standard curve Grenzkurven limit curves 2 K/s 150 200 t LW G6SP +0 ˚C -5 ˚C ±5 ˚C +5 ˚C -0 ˚C 300 OHLY0598 s 250 ...

Page 15

... Forward Voltage Group Wavelength Group Brightness Group OHA12043 Label Direction of unreeling Gurtvorlauf: 400 mm Leader: 400 mm Gurtende: 160 mm Trailer: 160 1.5 + 0.1 1.75 ± 0.1 (0.059 + 0.004) (0.069 ± 0.004) LW G6SP OHAY0324 F 5.5 ± 0.05 (0.217 ± 0.002 max 18.4 (0.724) 18.4 (0.724) ...

Page 16

... Comparator dot check WET units bake 15% necessary if units, examine wet, If units bake 10% necessary if units, wet, examine If dry. adequately desiccant still change parts 5% wet, If MIL-I-8835 Indicator Humidity Desiccant Barcode label 16 Humidity indicator Barcode label OHA00539 Barcode label Packing Sealing label LW G6SP OHA02044 ...

Page 17

... Components used in life-support devices or systems must be expressly authorized for such purpose! Critical 10) page 18 components may only be used in life-support devices or systems OSRAM OS. 2009-07-21 11) page 18 with the express written approval G6SP Date of change 2005-12-19 2006-01-16 2006-05-23 2006-07-28 2006-08-30 2006-11-10 2006-11-13 2006-12-14 2007-07-31 ...

Page 18

... Life support devices or systems are intended ( implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail reasonable to assume that the health and the life of the user may be endangered. 18 figures. These do not If requested, e.g. because application note on our LW G6SP necessarily of technical web site ...