BXRA-N3500-00000 Bridgelux, BXRA-N3500-00000 Datasheet

LED ARRAY NEUTRAL WHITE 3800LM

BXRA-N3500-00000

Manufacturer Part Number
BXRA-N3500-00000
Description
LED ARRAY NEUTRAL WHITE 3800LM
Manufacturer
Bridgelux
Series
RSr
Type
Without Connectorr
Datasheet

Specifications of BXRA-N3500-00000

Color
White, Neutral
Luminous Flux @ Current - Test
3800 lm
Current - Test
2.1A
Current - Max
3A
Driver Circuitry
No
Voltage
25.6V
Wavelength
4100K
Configuration
Square
With Connector
No
Voltage - Input
25.6V
Led Color
Neutral White
Luminous Flux @ Test
3800lm
Cct
4750K
Forward Current @ Test
2.1A
Forward Current If Max
3A
Forward Voltage @ Test
25.6V
Viewing Angle
120°
Led Mounting
SMD
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-
Power - Input
-
Other names
976-1016
Bridgelux RS Array Series
Product Data Sheet DS15
Introduction
The Bridgelux family of LED Array products delivers high performance, compact and cost-effective solid-
state lighting solutions to serve the general lighting market. These products combine the higher efficacy,
lifetime, and reliability benefits of LEDs with the light output levels of many conventional lighting sources.
The Bridgelux RS Array Series has been specified to enable lamp and luminaire designs with comparable
performance to existing high wattage CFL and HID conventional light sources for retail, commercial,
industrial and street lighting applications.
The Bridgelux RS Array series provides a high performance alternative to conventional solid state
solutions, delivering between 3000 and 4500 lumens under application conditions in warm and cool white
color temperatures. These compact high flux density light sources deliver uniform high quality
illumination without pixilation or the multiple shadow effect caused by LED component based solutions,
enabling excellent beam control for precision lighting. To simplify system design for appropriate light
output, Bridgelux LED Arrays are specified to deliver performance under typical use conditions.
These integrated plug and play solutions reduce system complexity and enable miniaturized cost-
effective lamp and luminaire designs. Lighting system designs incorporating these LED Arrays deliver
performance comparable to that of a 2x26 Watt CFL, 42-55 Watt CFL, 35-55 Watt low pressure sodium,
70-Watt high pressure sodium or 70-100 Watt metal halide based luminaires and feature increased
system level efficacy and service life. Typical applications include retail lighting, commercial down lights,
high bay, street lights, bollards, wide area, and entertainment lighting.
 
Features
1 1 70 So no ra Ct, Su nn yva l e , CA 94 08 6 • Te l: (4 0 8) 99 0- 75 0 0 • F a x: ( 40 8) 9 90 -7 5 01 • www. b ri d ge lu x.c o m
Compact high flux density light source
Uniform high quality illumination
Streamlined thermal path
Energy Star / ANSI compliant binning
structure
More energy efficient than
incandescent, halogen and fluorescent
lamps
Low voltage DC operation
Instant light with unlimited dimming
Long operating life
RoHS compliant and Pb free
Benefits
Enhanced optical control
Clean white light without pixilation
Significantly reduced thermal resistance
and increased operating temperatures
Uniform consistent white light
Lower operating costs
Increased safety
Easy to use with daylight and motion
detectors to enable increased energy
savings
Reduced maintenance costs
Environmentally friendly, no disposal issue

Related parts for BXRA-N3500-00000

BXRA-N3500-00000 Summary of contents

Page 1

... LEDs with the light output levels of many conventional lighting sources. The Bridgelux RS Array Series has been specified to enable lamp and luminaire designs with comparable performance to existing high wattage CFL and HID conventional light sources for retail, commercial, industrial and street lighting applications ...

Page 2

... Typical Chromaticity Characteristics vs. Temperature Typical Forward Current Characteristics Current Derating Curves Product Binning Luminous Flux Binning Information Color Binning Information Mechanical Assembly and Handling Product Packaging and Labeling Packaging Tube Design Design Resources Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) Page ...

Page 3

... E – designates product family – used to designate product options, 00000 by default The base product part number (BXRA-ABCDE) is indicated on each individual unit, printed on the bottom of the LED Array. Average Lumen Maintenance Characteristics Bridgelux projects that its family of LED Array products will deliver, on average, greater than 70% lumen maintenance after 50,000 hours of operation at the rated forward test current. This performance assumes constant current operation with case temperature maintained at or below 70° ...

Page 4

... UL Recognition Bridgelux is in the process of securing UL Recognition for the LED Array products. This process is expected to be complete in February 2010. Bridgelux uses UL Recognized materials with suitable flammability ratings in the LED Array to streamline the process for customers to secure UL listing of the final luminaire product. Bridgelux recommends that luminaires are designed with a Class 2 Driver to facilitate the UL listing process ...

Page 5

... Case Temperature Measurement Point A case temperature measurement point location is included on the top surface of the Bridgelux LED Arrays. The location of this measurement point is indicated in the mechanical dimensions section of this data sheet. The purpose of this measurement point is to allow the user access to a measurement point closely linked to the true case temperature on the back surface of the LED Array ...

Page 6

... Number Warm White BXRA-W3000 Cool White BXRA-C4500 Notes for Table 1: 1. Bridgelux maintains a ± 7% tolerance of flux measurements. 2. Parts are tested in pulsed conditions 25°C. Pulse width rated test current. 3. Typical performance when driven with direct current using Bridgelux test set-up. Please contact a ...

Page 7

... Base Part Number Warm BXRA-W3000 White Cool BXRA-C4500 White Notes for Table 2: 1. Parts are tested in pulsed conditions 25°C. Pulse width rated test current. 2. Refer to Flux Characteristic Table for test current data. 3. Product is binned for color coordinates. 4. Higher CRI options available upon request. ...

Page 8

... Number Min Warm BXRA-W3000 23.4 White Cool BXRA-C4500 23.4 White Notes for Table 3: 1. Parts are tested in pulsed conditions 25°C. Pulse width rated test current. 2. Bridgelux maintains a tester tolerance of ± 0. forward voltage measurements. Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) ...

Page 9

... Absolute Minimum and Maximum Ratings Table 4: Minimum and Maximum Current and Reverse Voltage Ratings Maximum Part Number DC Forward Current (mA) BXRA-W3000 3000 BXRA-C4500 3000 Parameter LED Junction Temperature Storage Temperature Operating Case Temperature Soldering Temperature Notes for Table 4: 1. Light emitting diodes are not designed to be driven in reverse voltage. ...

Page 10

... Part Number Warm White BXRA-W3000 Cool White BXRA-C4500 Notes for Table 6: 1. Product is tested and binned at the specified drive current. 2. Operating these LED Arrays at or below the drive currents listed in Table 6, with a case temperature maintained at or below 70°C, will enable the average lumen maintenance projection outlined earlier in this Product Data Sheet ...

Page 11

... Mechanical Dimensions Figure 1: Drawing for part numbers BXRA-W3000 and BXRA-C4500. Notes for Figure 1: 1. Slots are for M2. screws. 2. Solder pads are labeled “+” and “-“ to denote positive and negative, respectively not necessary to provide electrical connections to both sets of solder pads. Either set of solder pads (6 ...

Page 12

... Typical Radiation Pattern Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) Figure 2: Typical Spatial Radiation Pattern Figure 3: Typical Polar Radiation Pattern Page ...

Page 13

... Wavelength Characteristics at Rated Test Current, T Figure 5: Typical Cool White Color Spectrum Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) =25°C j Figure 4: Typical Warm White Color Spectrum Page ...

Page 14

... Note for Figure 6: Bridgelux does not recommend driving high power LED Arrays at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) =25° Figure 6: Typical Flux vs. Current Current (mA) BXRA‐W3000 BXRA‐C4500 Page ...

Page 15

... Typical Light Output Characteristics vs. Temperature Figure 7: Typical Flux vs. Junction Temperature 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 -30 -20 -10 0 Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) Warm White Cool White Junction Tem perature , 100 Page ...

Page 16

... Figure 9: Typical y Shift vs. Junction Temperature 0.02 0.01 0 -0.01 -0.02 -0.03 -0.04 -0.05 -0.06 - Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) Warm White Cool White Junction Temperature Junction Temperature Warm White Cool White 60 70 ...

Page 17

... Typical Forward Current Characteristics at T Figure 10: Typical Current vs. Voltage, BXRA-W3000 and BXRA-C4500 4400 4000 3600 3200 2800 2400 2000 1600 1200 800 400 0 23.0 23.4 23.8     Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) = 25°C j 24.2 24.6 25.0 25.4 25.8 Forward  ...

Page 18

... LED Array. Individual LED Array thermal resistance values are listed in Table 3. Figure 11: Derating Curve, 2100mA Drive Current 2500 2000 1500 1000 500   Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) 1.0˚C/W 0.7˚C/W 0.4˚C Ta ‐ Ambient Temperature,  ...

Page 19

... In order to minimize variation in the end product or application, Bridgelux bins its LED Arrays for luminous flux and color. Bridgelux LED Arrays are labeled using a 4-digit alphanumeric bin code. This bin code is printed on the back of each LED Array in the following format: ...

Page 20

... P3 3500 0.4299  0.4165  0.4223  0.3990  0.4018 0.3752 0.4083  0.3921  P4 3500 0.4223  0.3990  0.4147  0.3814  Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11 ...

Page 21

... D3  6500  0.3205  0.3481  0.3117  0.3393  0.3145  0.3187  0.3221  0.3261  D4  6500  0.3213  0.3371  0.3131  0.3290  Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11 ...

Page 22

... Figure 14. To ensure proper thermal contact it is important to mount the LED Array to the heat sink using 4 mounting screws. Bridgelux recommends the use of hard non- electrically conductive flat washers with lock washers. The recommended center to center spacing for the four tapped holes for mounting the Bridgelux RS Series Array is shown in Figure 15. Refer to Application Note AN11 – ...

Page 23

... Notes for Figure 15: 1. Drawing dimensions are in millimeters.      Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) Figure 15: Recommended Center to Center Spacing for Tapped Mounting Holes   Page ...

Page 24

... Product Packaging and Labeling All Bridgelux LED Array products are 100% tested, binned and labeled. Products are labeled by printing pertinent information on the back side of the LED Array. The following format is used for labeling the Bridgelux LED Arrays – – Where – designates the bin code (EQ30, etc – ...

Page 25

... Product Packaging and Labeling (continued) Tubes of Bridgelux LED Arrays are packaged in bags prior to loading into boxes for shipment. One tube is loaded per bag, resulting in an SPI of 10. All products packaged within a single bag are of the same flux and color bin combination (or bin code). Each bag is labeled with the information required for effective inventory management ...

Page 26

... – designates the bin code (EQ30, etc – designates the date code (production week and production year, 0210, etc – designates the quantity per listed bin code contained in the box. Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11) Figure 18: Box Label Example   ...

Page 27

... Notes for Figures 19: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. Bridgelux RS Array Series Product Data Sheet DS15 (03/14/11)   Page ...

Page 28

... AN16: Optical Considerations for Bridgelux LED Arrays Optical Source Models Optical source models and ray set files are available for all Bridgelux LED Array products, and can be downloaded directly from the Bridgelux web site. The list below contains the formats currently available. ...

Page 29

... Based in Silicon Valley, Bridgelux is a pioneer in solid-state lighting (SSL), expanding the market for solid state lighting by driving down the cost of light through innovation. Bridgelux’ ...

Related keywords