KMD40-512 TDK Corporation, KMD40-512 Datasheet

PWR SUP MEDICAL 5V/12V 1.25A 40W

KMD40-512

Manufacturer Part Number
KMD40-512
Description
PWR SUP MEDICAL 5V/12V 1.25A 40W
Manufacturer
TDK Corporation
Series
KMr
Type
Medicalr
Datasheets

Specifications of KMD40-512

Power Supply Type
Switching (Closed Frame)
Voltage - Output
5V, 12V
Number Of Outputs
2
Power (watts)
40W
Applications
Medical
Voltage - Input
90 ~ 264VAC
Mounting Type
Through Hole
1st Output
5 VDC @ 5A
2nd Output
12 VDC @ 1.25A
Size / Dimension
3.5" L x 2.5" W x 1.06" H (89mm x 63.5mm x 27mm)
Power (watts) - Rated
40W
Operating Temperature
-25°C ~ 70°C
Efficiency
80%
Approvals
CE, EN, IEC, UL
Line Regulation
0.5%, 5%
Load Regulation
2%, 6%
Power Supply Output Type
Fixed
No. Of Outputs
2
Output Voltage
5V
Output Current
5A
Power Rating
40W
Input Voltage
90V AC To 264V AC / 100V DC To 375V DC
Length
88.9mm
Brand/series
KM Series
Configuration
Encapsulated
Operation
Switching
Output
5 VDC @ 1250 mA to 5 A, 12 VDC @ 312 mA to 1.25 A
Power, Output
40 W
Primary Type
AC-DC
Special Features
High Efficiency
Voltage, Input
90 to 264/100 to 375 VAC/VDC
Voltage, Output
5, 12 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
285-1780
KMD40512

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KMD40-512
Manufacturer:
TDK-LAMBDA
Quantity:
253
Features and Benefits
Specifications
Feature
ITEMS
Input Voltage Range
Inrush Current Limiting
Input Current (115 / 230VAC)
Recommended External Fuse
Temperature Coefficient
Ripple and Noise (pk-pk)
Overcurrent Protection
Overvoltage Protection
Hold-up Time (typical)
Enclosure Leakage (240VAC 63Hz)
Operating Temperature
Storage Temperature
Humidity
Cooling
Withstand Voltage
Immunity
Safety Agency Certification
Conducted EMI
Switching Frequency
Weight
Size (LxWxH)
Mounting & Case
MTBF
Warranty
(1)
Small size
Wide input range
High efficiency
KM15 derates linearly to 40% load
(264VAC 63Hz)
MODELS
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324
%RH
VAC
kHz
mA
mA
mV
hrs
ms
yrs
in
A
%
g
-
-
-
-
-
-
-
-
-
-
-
-25°C to 70°C, derate linearly to 50%(1) load from 50°C to 70°C. Max case temperature 95°C
15-40W Medical AC-DC PCB-Mount Power Supplies
KMS15
EN55011, EN55022 Class B
2.52 x 1.79 x 0.92"
Convection, over temperature protected ~100°C case temperature
2A slow blow type
220 / 118mA
PC board mountable. Plastic resin fiberglass case (UL 94V-0)
0.055 max
0.06 max
KMD15
20ms
120
10 / 20A, cold start, 25°C ambient (115 / 230VAC)
UL60601-1, IEC60601-1, CE Mark, EN60950-1
200,000 to 400,000 hours, model dependent
> 105%, hiccup mode, automatic recovery
90-264VAC 47-440Hz or 100-375VDC
Benefit
Minimizes pcb space
Global use with no manual intervention
Lower heat dissipated in system
50mV or 1%, whichever is greater
20% to 95% RH (non-condensing)
Small size and lightweight
PC Board Mountable
Wide Range Input
Medical Safety Certifications (4kVAC Input - Output)
Class II (No ground needed)
KM Series
Yes, Zener diode clamp
Input to output: 4kVAC
KMT15
-40°C to 100°C
EN60601-1-2
±0.01%/°C
132kHz
2 years
KMS40
EN55011, EN55022 Class A
3.15A slow blow type
3.5 x 2.5 x 1.06"
860 / 460mA
0.085 max
0.08 max
KMD40
18ms
280
KMT40
67

Related parts for KMD40-512

KMD40-512 Summary of contents

Page 1

... EN60601-1-2 UL60601-1, IEC60601-1, CE Mark, EN60950-1 EN55011, EN55022 Class B 120 2.52 x 1.79 x 0.92" PC board mountable. Plastic resin fiberglass case (UL 94V-0) 200,000 to 400,000 hours, model dependent KMS40 KMD40 860 / 460mA 3.15A slow blow type 18ms 0.08 max 0.085 max EN55011, EN55022 Class A 132kHz 280 3.5 x 2.5 x 1.06" ...

Page 2

... KMS40-15 V1 15V 26.7mA KMS15-24 V1 24V KMS40-24 V1 24V 16.7mA Dual Output KMD15-55 V1 +5V 150mA V2 -5V 150mA KMD40-55 V1 +5V 400mA V2 -5V 400mA KMD40-512 V1 5V(2) 1250mA V2 12V(2) 312mA KMD40-524 V1 5V(2) 1250mA V2 24V(2) 156mA KMD15-1212 V1 +12V 62.5mA V2 -12V 62.5mA KMD40-1212 V1 +12V 166mA V2 -12V 166mA ...