NKE0505SC Murata Power Solutions Inc, NKE0505SC Datasheet - Page 3

CONV DC/DC 1W 5VIN 5VOUT SIP SGL

NKE0505SC

Manufacturer Part Number
NKE0505SC
Description
CONV DC/DC 1W 5VIN 5VOUT SIP SGL
Manufacturer
Murata Power Solutions Inc
Series
NKEr
Type
Isolatedr
Datasheet

Specifications of NKE0505SC

Number Of Outputs
1
Output
5V
Power (watts)
1W
Mounting Type
Through Hole
Voltage - Input
4.5 ~ 5.5V
Package / Case
4-SIP Module
1st Output
5 VDC @ 200mA
Size / Dimension
0.45" L x 0.24" W x 0.29" H (11.4mm x 6.1mm x 7.4mm)
Power (watts) - Rated
1W
Operating Temperature
-40°C ~ 85°C
Efficiency
69%
Approvals
cUL, UL
Output Power
1 W
Input Voltage Range
4.5 V to 5.5 V
Input Voltage (nominal)
5 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
200 mA
Isolation Voltage
3 KV
Package / Case Size
SIP
Output Voltage
5 V
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1434-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NKE0505SC
Manufacturer:
KOE
Quantity:
12 000
Part Number:
NKE0505SC
Manufacturer:
MURATA
Quantity:
4 000
Part Number:
NKE0505SC
Manufacturer:
MURATA/村田
Quantity:
20 000
TEMPERATURE DERATING GRAPHS
TOLERANCE ENVELOPES
NKE 0303DC/SC, 0305DC/
SC, 0309DC/SC, 0503DC/SC,
0505DEC/SEC types only.
UL recognition to a
maximum ambient
temperature of 85ºC and/
or case temperature limit of
130ºC.
www.murata-ps.com
3.3V output types.
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.
V
+9%
+1%
NOM
-7%
10
25
Output Load Current (%)
1.5
1.0
0.5
0
-40
Safe Operating Area
50
Ambient Temperature (°C)
0
75
50
85°C
100
+1%
-7%
-15%
100
150
All other types.
Isolated Sub-Miniature 1W Single Output DC/DC Converters
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
All other types.
+10%
+5%
V
NOM
10
25
Output Load Current (%)
1.5
1.0
0.5
0
-40
Safe Operating Area
Ambient Temperature (°C)
50
2010-07-14 KDC_NKE.K01 Page 3 of 7
0
75
NKE Series
50
85°C
100
100
+2.5%
-2.5%
-7.5%
120°C
150

Related parts for NKE0505SC