NTH0505MC Murata Power Solutions Inc, NTH0505MC Datasheet - Page 2

CONV DC/DC SM 2W 5VIN 5VDUAL 1KV

NTH0505MC

Manufacturer Part Number
NTH0505MC
Description
CONV DC/DC SM 2W 5VIN 5VDUAL 1KV
Manufacturer
Murata Power Solutions Inc
Series
NTHr
Type
Isolatedr
Datasheet

Specifications of NTH0505MC

Number Of Outputs
2
Output
±5V
Power (watts)
2W
Mounting Type
Surface Mount
Voltage - Input
4.5 ~ 5.5V
Package / Case
26-DIP SMD Module (12 Leads)
1st Output
5 VDC @ 200mA
2nd Output
-5 VDC @ 200mA
Size / Dimension
0.70" L x 0.50" W x 0.23" H (17.8mm x 12.7mm x 5.8mm)
Power (watts) - Rated
2W
Operating Temperature
-40°C ~ 85°C
Efficiency
80%
Approvals
UL
Output Power
1 W
Input Voltage Range
4.5 V to 5.5 V
Input Voltage (nominal)
5 V
Output Voltage (channel 1)
+/- 5 V
Output Current (channel 1)
+/- 200 mA
Output Voltage (channel 2)
+/- 5 V
Output Current (channel 2)
+/- 200 mA
Isolation Voltage
1 KV
Output Voltage
+/- 5 V
Product
Isolated
Lead Free Status / RoHS Status
Lead free by exemption / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1689-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NTH0505MC
Manufacturer:
MURATA
Quantity:
2 100
Part Number:
NTH0505MC
Manufacturer:
MURATA/村田
Quantity:
20 000
5V output types
TEMPERATURE CHARACTERISTICS
Parameter
Specifi cation
Storage
Case temperature rise above
ambient
Cooling
TOLERANCE ENVELOPE
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NTH series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specifi c agency approvals, such as the NTH series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NTH series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specifi ed test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
RoHS COMPLIANCE INFORMATION
www.murata-ps.com
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.
For further information, please visit www.murata-ps.com/rohs
+3.75%
+7.5%
0%
10
25
Output Load Current (%)
This series is compatible with RoHS soldering
systems with a peak refl ow solder temperature
of 245ºC and time above liquidus of 217ºC
for 60 seconds. The pin termination fi nish on
this product series is Gold, plating thickness
0.1 microns minimum. The series is backward
compatible with Sn/Pb soldering systems.
Conditions
All output types
5V output types
All other output types
Free air convection
50
75
100
+2.5%
-1.25%
-5.0%
TEMPERATURE DERATING GRAPH
All other output types
Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232
+1.5%
-2.0%
Isolated 2W Dual Output SM DC/DC Converters
+5%
10
3.0
2.0
1.0
25
Output Load Current (%)
0
-40
Safe Operating Area
Ambient Temperature (°C)
50
0
Min.
-40
-55
2010-07-08 KDC_NTHC.C01 Page 2 of 6
75
50
85°C
Typ.
30
25
100
100
NTH Series
+2.0%
-1.5%
-5.0%
150
Max.
125
85
Units
°C