UWE-12/6-Q12N-C Murata Power Solutions Inc, UWE-12/6-Q12N-C Datasheet

CONV DC/DC 12V 72W 6A

UWE-12/6-Q12N-C

Manufacturer Part Number
UWE-12/6-Q12N-C
Description
CONV DC/DC 12V 72W 6A
Manufacturer
Murata Power Solutions Inc
Series
UWEr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of UWE-12/6-Q12N-C

Output
12V
Number Of Outputs
1
Power (watts)
72W
Mounting Type
Through Hole
Voltage - Input
9 ~ 36V
Package / Case
8-DIP Module, 1/8 Brick
1st Output
12 VDC @ 6A
Size / Dimension
2.30" L x 0.90" W x 0.38" H (58.4mm x 22.9mm x 9.7mm)
Power (watts) - Rated
72W
Operating Temperature
-40°C ~ 85°C
Efficiency
91.5%
Approvals
CAN, CSA, EN, IEC, UL
Output Power
72 W
Input Voltage Range
9 V to 36 V
Output Voltage (channel 1)
12 V
Output Current (channel 1)
6 A
Isolation Voltage
1.5 KV
Product
Isolated
Input Voltage (nominal)
12 V
Package / Case Size
C77
Output Type
Isolated
Output Voltage
12 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
FEATURES
FEATURES
www.murata-ps.com
Industry-standard through-hole eighth-brick
package with 0.9" x 2.3" x 0.38" outline
dimensions
Choice of two wide input ranges, 9-36 Vdc or
18-75 Vdc
Fixed output from 3.3 to 24 Volts DC up to 75
Watts
Synchronous rectifi cation yields very high
effi ciency and low power dissipation
Operating temperature range from -40 to
+85˚C with derating
Up to 2250 Volt DC isolation (Q48 models)
Outstanding thermal performance and derating
Extensive self-protection, overtemperature
and overload features with no output reverse
conduction
On/Off control, trim and remote sense functions
Certifi ed to UL/EN/IEC 60950-1, CAN/CSA-C22.2
No. 60950-1, 2nd Edition, safety approvals
and EN55022/CISPR22 standards
Pre-bias operation for startup protection
www.murata-ps.com/rohs
For full details go to
 
CONTROL
ON/OFF
+V
–V
IN
IN
Typical unit
SS
UV, OT
REGULATOR
VOLTAGE
PWM
The UWE Series "Eighth-Brick" DC/DC Converters are high-current isolated
T
power modules designed for use in high-density system boards.
inches, the UWE series open frame DC/DC convert-
ers deliver up to 75 Watts in an industry-standard
“eighth-brick” through-hole package. This format
can plug directly into quarter-brick pinouts. Several
standard fi xed-output voltages from 3.3 Vdc to 24
Vdc assure compatibility in embedded equipment,
CPU cards and instrument subsystems. The extend-
ed 4-to-1 input power range (9-36V) is ideal for
battery-powered, telecom or portable applications.
Very high effi ciency means no fans or temperature
deratings in many applications. An optional thermal
mounting baseplate extends operation into most
conceivable environments.
maximum available duty cycle for greatest ef-
fi ciency and low power dissipation with no reverse
output conduction. Other features include low
on-resistance FET’s, planar magnetics and heavy-
copper PC boards. These deliver low output noise,
PRODUCT OVERVIEW
With dimensions of only 0.9 by 2.3 by 0.38
The synchronous rectifi er design uses the
www.murata-ps.com
ISOLATION
Figure 1. Simplifi ed Block Diagram
TRIM AND FEEDBACK
SWITCH
DRIVE
REFERENCE
AMPLIFIER,
Typical topology is shown.
tight line/load regulation, stable no-load operation
and fast load step response. All units are precision
assembled in a highly automated facility with ISO-
traceable manufacturing quality standards.
safety and fully differential (fl oating) operation for
greatest application fl exibility. On-board Sense in-
puts compensate for line drop errors at high output
currents. Outputs are trimmable within ±10% of
nominal voltage. The UWE series are functionally
complete.
to both the converter and outside circuits. Inputs
are protected from undervoltage and outputs fea-
ture short circuit protection, overcurrent and excess
temperature shut down. Overloads automatically
recover using the “hiccup” technique upon fault
removal. The UWE is certifi ed to standard safety
and EMI/RFI approvals. All units meet RoHS-6
hazardous materials compliance.
Isolation of 2250 Volts (Q48 models) assures
A wealth of protection features prevents damage
14 Mar 2011 MDC_UWE Series.A28 Page 1 of 23
Eighth-Brick DC/DC Converters
+V
+SENSE
−V
−SENSE
TRIM
OUT
OUT
email: sales@murata-ps.com
UWE Series
Wide Input, Isolated

Related parts for UWE-12/6-Q12N-C

UWE-12/6-Q12N-C Summary of contents

Page 1

... Overloads automatically recover using the “hiccup” technique upon fault removal. The UWE is certifi standard safety and EMI/RFI approvals. All units meet RoHS-6 hazardous materials compliance. +V ...

Page 2

... RoHS Hazardous Materials Compliance C=RoHS-6, standard (does not claim EU RoHS exemption 7b–lead in solder) email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page Package (Case, Pinout) Typ. 89% 89.5% 91% 90% 91.5% C77, P32 91% 91.5% 90.5% 89.5% ...

Page 3

... See ordering guide No minimum load +10% max. See ordering guide See ordering guide See ordering guide 4,700 4700 1500 1500 750 100 1000 1000 Basic insulation 8.5 7.25 1.5 1 email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page UWE-24/3-Q12 250 110 9.04 5 1500 1000 4.0 1.0 29 ...

Page 4

... Copper alloy 0.04/0.062 1.016/1.575 0.7 20 UWE-12/6-Q48 UWE-15/5-Q48 See ordering guide 17.5 16.0 none sec 100 90 4.35 4 Pi-type 1 email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page UWE-24/3-Q12 40 30 215 ±15 17 sec 250 90 4.71 5 L-C ...

Page 5

... Eighth-Brick DC/DC Converters UWE-12/6-Q48 UWE-15/5-Q48 +10% max. 4,700 2250 1500 750 100 1000 8.0 1 (to ± 1%) 50 (to ± 1 220±20 -55 to +125 +100 +120 Copper alloy 0.04/0.062 1.016/1.575 0.7 20 email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page 3300 1000 7.05 1 225±25 +105 +120 ...

Page 6

... To avoid thermal self- protection shutdown, do not exceed this maximum baseplate temperature. 18 UWE-24/3-Q12 undervoltage shutdown of 8. half load. 19 UWE-24/3-Q12 output overvoltage protection requires 0.3A minimum load. 20 Pre-bias operation: Startup will succeed if the output setpoint voltage is higher than the pre-existing external output voltage ...

Page 7

... Dimensions are in inches (mm) shown for ref. only. Third Angle Projection Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ Components are shown for reference only. email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page ...

Page 8

... Dimensions are in inches (mm) shown for ref. only. Third Angle Projection Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ Components are shown for reference only. email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page 0.48 (12.2 ±0.5) ...

Page 9

... SHIPPING TRAYS AND BOXES For 1–42 pc quantity SHIPPING TRAY UWE modules are supplied in a 21-piece (3-by-7) shipping tray. The tray is an anti-static closed-cell polyethylene foam. Dimensions are shown below. 0.735 (18.7) 9.920 (252) +0.000 -0.062 0.625 (15.9) TYP 2.400 (61) TYP 1.06 (26 ...

Page 10

... UWE Series Wide Input, Isolated Eighth-Brick DC/DC Converters Maximum Current Temperature Derating @sea level (V = 12V, transverse airfl ow, with baseplate) IN Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (° email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page ...

Page 11

... LFM 300 LFM 400 LFM Ambient Temperature (°C) Maximum Current Temperature Derating @sea level (V = 48V, transverse airfl ow, with baseplate) IN Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (°C) email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page ...

Page 12

... UWE Series Wide Input, Isolated Eighth-Brick DC/DC Converters Maximum Current Temperature Derating @sea level (V = 12V, transverse airfl ow, with baseplate) IN Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (°C) email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page ...

Page 13

... Natural Convection 100 LFM 200 LFM Ambient Temperature (°C) Maximum Current Temperature Derating @sea level (V = 48V, transverse airfl ow, with baseplate) IN Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (°C) email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page ...

Page 14

... Maximum Current Temperature Derating @sea level (V = 12V, transverse airfl ow, with baseplate) IN 6.0 Natural Convection 100 LFM 5.5 200 LFM 300+ LFM 5.0 4.5 4 Ambient Temperature (° email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page Vin Vin = Vin = Vin = Vin Vin = Vin = Vin = ...

Page 15

... Natural Convection 100 LFM 200 LFM Ambient Temperature (°C) Maximum Current Temperature Derating @sea level (V = 48V, transverse airfl ow, with baseplate) IN Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (°C) 4 4.5 5 email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page ...

Page 16

... IN Natural Convection 100 LFM 200 LFM Ambient Temperature (°C) Maximum Current Temperature Derating @sea level (V = 24V, transverse airfl ow, with baseplate) IN Natural Convection 100 LFM 200 LFM Ambient Temperature (° email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page ...

Page 17

... Ambient Temperature (°C) Maximum Current Temperature Derating @sea level (Vin = 60V, air fl ow from Pin 1 to Pin 3 on PCB, no baseplate) 65 LFM 100 LFM 200 LFM 300 to 400 LFM Ambient Temperature (°C) Ambient Temperature (°C) email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page ...

Page 18

... Ambient Temperature (°C) Maximum Current Temperature Derating @sea level (V = 24V, transverse airfl ow, with baseplate) IN Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM Ambient Temperature (°C) email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page Vin Vin = Vin = Vin = Vin Vin = Vin = Vin = 2 ...

Page 19

... I/O Filtering, Input Ripple Current, and Output Noise All models in the UWE Converters are tested/specifi ed for input refl ected ripple current and output noise using the specifi ed external input/output components/ circuits and layout as shown in the following two fi gures. ...

Page 20

... If the short-circuit condition persists, another shutdown cycle will be initiated. This on/off cycling is referred to as "hiccup" mode. The hiccup cycling reduces the average output current, thereby preventing internal temperatures from rising to excessive levels. The UWE is capable of enduring an indefi nite short circuit output condition. Features and Options ...

Page 21

... Trimming Output Voltage UWE converters have a trim capability that allows users to adjust the output voltages. Adjustments to the output voltages can be accomplished via a trim pot (Figure single fi xed resistor as shown in Figures 7 and 8. A single fi xed resistor can increase or decrease the output voltage depending on its connec- tion ...

Page 22

... T DOWN 24 – UWE’s specifi ed rating or cause output voltages to climb into the output over- voltage region. Also, the use of Trim Up and Sense combined may not exceed +10 desired output voltage. O DC/DC Converter ...

Page 23

... The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. www.murata-ps.com/locations UWE Series Wide Input, Isolated Eighth-Brick DC/DC Converters © 2009 Murata Power Solutions, Inc. email: sales@murata-ps.com 14 Mar 2011 MDC_UWE Series.A28 Page ...

Related keywords