ATH010A0X3-SRZ Lineage Power, ATH010A0X3-SRZ Datasheet - Page 2

CONVE DC/DC 0.75 3.63V @ 10A SMD

ATH010A0X3-SRZ

Manufacturer Part Number
ATH010A0X3-SRZ
Description
CONVE DC/DC 0.75 3.63V @ 10A SMD
Manufacturer
Lineage Power
Series
Austin Lynx™ IIr
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of ATH010A0X3-SRZ

Output
0.75 ~ 3.63V
Number Of Outputs
1
Power (watts)
36W
Mounting Type
Surface Mount
Voltage - Input
2.4 ~ 5.5V
Package / Case
7-SMD Module
1st Output
0.75 ~ 3.63 VDC @ 10A
Size / Dimension
1.30" L x 0.53" W x 0.33" H (33mm x 13.5mm x 8.3mm)
Power (watts) - Rated
36W
Operating Temperature
-40°C ~ 85°C
Efficiency
95%
Approvals
CSA, EN, UL, VDE
Output Power
22 W
Input Voltage Range
2.4 V to 5.5 V
Output Voltage (channel 1)
0.75 V to 3.63 V
Output Current (channel 1)
6 A
Package / Case Size
SMD
Output Type
Non-Isolated
Output Voltage
0.75 V to 3.63 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1081-2
CC109104543
Data Sheet
October 2, 2009
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of a complex power architecture. To preserve maximum flexibility, internal fusing is not included, however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a 15A,
time-delay fuse (see Safety Considerations section). Based on the information provided in this data sheet on inrush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse
manufacturer’s data sheet for further information.
LINEAGE
Parameter
Input Voltage
Operating Ambient Temperature
Storage Temperature
Parameter
Operating Input Voltage
Maximum Input Current
(V
Input No Load Current
Input Stand-by Current
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
V
Input Ripple Rejection (120Hz)
Sequencing voltage
IN, max,
Continuous
(see Thermal Considerations section)
(V
(V
IN
=2.4V to 5.5V, I
IN
IN
= 5.0Vdc, I
= 5.0Vdc, module disabled)
I
O
= I
POWER
Omax
; See Test Configurations)
O
= 0, module enabled)
O
=I
O, max
)
2.4 – 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 10A output current
IN, min
to
V
V
V
o
o
Austin Lynx
o
Device
≤ V
= 0.75Vdc
= 3.3Vdc
All
All
All
All
All
IN
- 0.5
Device
All
All
All
All
Symbol
I
TM
I
I
IN,stand-by
IN,No load
IN,No load
I
IN,max
V
I
II SMT Non-isolated Power Modules:
2
Symbol
IN
t
Vseq
T
V
T
stg
IN
A
Min
2.4
-0.3
-0.3
Min
-40
-55
Typ
100
1.5
25
30
30
V
Max
125
5.8
IN,max
85
Max
5.5
0.1
10
mAp-p
dB
Unit
Vdc
Vdc
°C
°C
Unit
Vdc
Adc
mA
mA
mA
A
2
s
2

Related parts for ATH010A0X3-SRZ