DC-DC CONVERTERS 12V 20W 1.67A

PXE2024WS12

Manufacturer Part NumberPXE2024WS12
DescriptionDC-DC CONVERTERS 12V 20W 1.67A
ManufacturerTDK Corporation
SeriesPXE
TypePoint of Load (POL) Non-Isolated with Remote On/Off
PXE2024WS12 datasheets
 


Specifications of PXE2024WS12

Output12VNumber Of Outputs1
Power (watts)20WMounting TypeThrough Hole
Voltage - Input9 ~ 36VPackage / Case8-DIP Module
1st Output12 VDC @ 1.67ASize / Dimension2.00" L x 1.60" W x 0.40" H (50.8mm x 40.6mm x 8.6mm)
Power (watts) - Rated20WOperating Temperature-40°C ~ 100°C
Efficiency81%ApprovalsCE, CSA, EN, UL
Dc / Dc Converter O/p TypeFixedNo. Of Outputs1
Input Voltage9V To 36VPower Rating20W
Output Voltage12VOutput Current1.67A
Approval BodiesUL, CSA, CESupply Voltage36V
Brand/seriesPXE SeriesConfigurationEnclosed
OperationSwitchingPower, Output20 W
Primary TypeDC-DC ConverterSpecial FeaturesRemote On/Off
Voltage, Input9 to 36 VDCVoltage, Output12 VDC
Lead Free Status / RoHS StatusLead free / RoHS Compliant3rd Output-
2nd Output-Other names285-1528
PXE20-24WS12
1
Page 1
2
Page 2
Page 1/2

Download datasheet (229Kb)Embed
Next
F e a t u r e s & B e n e f i t s
Feature
UL, CSA, EN, CE approvals
Wide range input
Six sided shielding
S p e c i f i c a t i o n s
ITEMS
Max Output Power
Voltage Accuracy
Voltage Adjustment
Minimum Load, each output
Line Regulation
Load Regulation (25% to 100%)
Cross Regulation (25% to 100%)
Ripple and Noise (P-P)
Start up time
Remote on/off
Temperature Coefficient
Operating Temperature
Maximum Case Temperature
Storage Temperature
Thermal Shock
Relative Humidity (non condensing)
Transient Response (25% step load change)
Overvoltage Protection (Zener clamp)
Overcurrent and Short Circuit Protection
Input Surge Voltage (Maximum for 100ms)
Reflected input ripple (peak to peak)
Isolation Voltage
Isolation Resistance
Isolation Capacitance (max)
Typical Switching Frequency (Fixed)
MTBF (BELLCORE TR-NWT-000332)
Vibration
Conducted and Radiated Emissions
Immunity
Safety Agency Approval
Size (L x W x H)
Weight
Warranty
Notes:
(1) To meet regulation & noise specifications. Operation at zero load will not damage the device
(2) 12uH source impedance in series with + input
(3) Max sink current 20mA (PXE20), 2.5mA (PXE30); The on/off pin is referenced to the negative input
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324
PXE Series
Single and Dual Output 20W to 30W DC-DC Converters
Industry Standard 2" x 1.6" Footprint
Six Sided Shielding
Agency Approved
12V, 24V and 48V Inputs
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Telecom, Datacom, Point of Load
Benefit
Easier system approvals
Less parts to inventory
Reduced radiated noise
PXE20
20W
±2%
(1)
10%
±0.2% for single, ±0.5% for dual
Single ±0.5%, Dual ±3%
Single: 75mV; Dual: 100mV
20ms - 1100ms typ.
(3)
Positive Logic: ON: Open or 3.5-12V, OFF Short or <1.2V
-40 to +100°C, see derating curve
100°C (Over temperature protection at 115°C - PXE30 model)
500us recovery
3.3V: 3.9V, 5V: 6.2V, 12V: 15V, 15V: 18V
Typically at 150%, hiccup with self recovery
12V input: 36V, 24V input: 50V, 48V input: 100V
(2)
25mA
1600VDC minimum (Input-Output, Input-Case)
300pF
1,976,000 hours
10 - 55Hz, 2G, 30 minutes each X, Y, Z axis
EN61000-4-2, -3, -4, -5, -6 Pref Criteria 2
IEC60950-1, UL60950-1, EN60950-1, CE Mark (48V input only)
PXE30
30W
±1%
±10%
10%
Single ±0.5%, Dual ±1%
Dual ±5%
10 - 25ms typ.
<±0.02%/°C
-55 to 105°C
MIL-STD-810D
5 to 95%
300us recovery
30mA
10
Ohms minimum
9
1000pF
300kHz
1,535,000 hours
EN55022 Level A
2 x 1.6 x 0.4"
1.69 oz (48g)
Two Year
153

PXE2024WS12 Summary of contents

  • Page 1

    & Feature UL, CSA, EN, CE approvals Wide range input Six sided shielding ...

  • Page 2

    Model Selector Output Output Output Input Volt (V) Curr (A) Power (W) Volt (VDC) Single Outputs 3.3 6 3.3 6 3.3 6 3.3 6 ...