PIM200FZ Lineage Power, PIM200FZ Datasheet
PIM200FZ
Specifications of PIM200FZ
CC109101813
Related parts for PIM200FZ
PIM200FZ Summary of contents
Page 1
Data Sheet March 29, 2007 PIM200X Series; ATCA Board Power Input Modules RoHS Compliant Applications ATCA Front Board / Blade Central Office Telecom equipment High availability server and storage applications Options Choice of System Management Power: 3.3Vdc (PIM200F) 5.0Vdc (PIM200A) ...
Page 2
Data Sheet March 29, 2007 200W ATCA Board Typical Application F5 (32) Short Pin ENABLE_A F6 (27) Short Pin ENABLE_B F1 (28) VRTN_A F2 (29) VRTN_B ATCA ATCA (25) Backplane Zone 1 SHELF_GND Connector R1 (Optional) (30) Long Pin EARLY_A ...
Page 3
Data Sheet March 29, 2007 Absolute Maximum Ratings: Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or ...
Page 4
Data Sheet March 29, 2007 Electrical Specifications: Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Main Input (-48_AF,-48_BF,VRTN_AF,VRTN_BF); (Absolute values) Operating Input Voltage (Module will operate down to –36V depending on the ...
Page 5
Data Sheet March 29, 2007 Electrical Specifications (continued): Parameter Management Power Output (MGMT_PWR) Operating Input Voltage Output Voltage Set-point (V = -48Vdc =25° max A Output Voltage (Over all operating input voltage, resistive ...
Page 6
Data Sheet March 29, 2007 PIM200X Internal Block Diagram ENABLE_AF (5) ENABLE_BF (6) VRTN_AF (3) VRTN_OR VRTN_BF (4) SHELF_GND (7) -48_AF (1) -48_OR -48_BF (2) LOGIC_GND (11) PIN FUNCTIONS PIN NO. PIN NAME 1 -48_AF 2 -48_BF 3 VRTN_AF 4 ...
Page 7
Data Sheet March 29, 2007 Characteristic Curves The following figures provide typical characteristics for the PIM200X modules at 25ºC. Figure 1. Inrush Current @ -75Vin & 3A Out CH1: -48_AF, CH2: -48V_OUT, CH4: Iin(-48_AF) Test Conditions: -48_AF=-75Vdc, -48V_BF=0Vdc I(-48V_OUT)=3A, I(MGMT_PWR)=0A ...
Page 8
Data Sheet March 29, 2007 Characteristic Curves (continued) The following figures provide typical characteristics for the PIM200X modules at 25ºC. Figure 5. Input Voltage Turn-On Threshold CH1: -48_AF, CH2: -48V_OUT, CH4: Iin(-48_AF) Test Conditions: -48_AF=-48Vdc, -48V_BF=0Vdc I(-48V_OUT)=1A, I(MGMT_PWR)=0A C_FLTR=220µF Figure ...
Page 9
Data Sheet March 29, 2007 Characteristic Curves (continued) The following figures provide typical characteristics for the PIM200X modules at 25ºC (unless specified otherwise). Figure 9. Typical Start-Up of MGMT_PWR(3.3Vdc) with application of –48Vin. CH1: -48_AF, CH2: MGMT_PWR (3.3Vdc) Output Test ...
Page 10
Data Sheet March 29, 2007 Design Considerations Introduction The PIM200X module is designed to support the Advanced Telecommunications Computing Architecture (ATCA) power entry distribution requirements for the Front Board / Blade per the PICMG 3.0 specifications. The PICMG 3.0 specification ...
Page 11
Data Sheet March 29, 2007 • The -48V_OUT bus may require a fuse depending on the power and fusing requirements of the DC/DC converter(s). • Input filtering of the DC/DC converter is provided by C_FLTR close to the input pins ...
Page 12
Data Sheet March 29, 2007 C22.2 No. 60950-1-03, and VDE 0850:2001-12 (EN60950-1) Licensed. The power input to these units provided with a maximum of 10 Amps fuses with a voltage rating of at least 75Vdc. Refer to ...
Page 13
Data Sheet March 29, 2007 Holdup Capacitor Charging Current (72V_CAP) The module employs a unique feature to charge and recharge the external energy storage holdup/bulk capacitors (C_HLDP) within seconds from the application of power to a nominal voltage of 72Vdc ...
Page 14
Data Sheet March 29, 2007 Considerations include ambient temperature, airflow, module power dissipation, and the need for increased reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The thermal data presented here ...
Page 15
Data Sheet March 29, 2007 Mechanical Outline for PIM200X Module Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.) ...
Page 16
Data Sheet March 29, 2007 Recommended Pad Layout Dimensions are in millimeters and (inches). Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated] x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.) NOTES: 1. ...
Page 17
... Basic Insulation 2.4A 1.6A RoHS 1.6A Product Code QBW018A0B1 QBW018A0B1Z* QBW018A0B1-TZ QBW025A0B1 QBW025A0B1Z* -38 to -75Vdc; 200W Input Product Comcodes codes PIM200F 108994471 PIM200FZ CC109101813 PIM200F-B CC109101912 PIM200A 108996286 PIM200AZ CC109106762 Suffix -B -Z Comcode N/A 848755868 108989356 TBD CC109101846 CC109102464 TBD ...
Page 18
Data Sheet March 29, 2007 World Wide Headquarters Tyco Electronics Power Systems, Inc. 3000 Skyline Drive, Mesquite, TX 75149, USA +1-800-526-7819 (Outside U.S.A.: +1-972-284-2626) www.power.tycoelectronics.com e-mail: techsupport1@tycoelectronics.com Tyco Electronics Corporation reserves the right to make changes to the product(s) or ...