ZPT4051515N TDK Corporation, ZPT4051515N Datasheet

PWR SUP TRIPLE +5V/+15V/-15V

ZPT4051515N

Manufacturer Part Number
ZPT4051515N
Description
PWR SUP TRIPLE +5V/+15V/-15V
Manufacturer
TDK Corporation
Series
ZP60r
Datasheets

Specifications of ZPT4051515N

Power Supply Type
Switching (Open Frame)
Voltage - Output
5V, ±15V
Number Of Outputs
3
Power (watts)
40W
Applications
Commercial
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 3.2A
2nd Output
15 VDC @ 1.5A
3rd Output
-15 VDC @ 300mA
Size / Dimension
4" L x 2" W x 1.2" H (101.6mm x 50.8mm x 30.5mm)
Power (watts) - Rated
42W
Operating Temperature
0°C ~ 70°C
Efficiency
75%
Approvals
CE, CSA, EN, UL
Line Regulation
±1%, ±2%
Load Regulation
±3%, ±5%, ±1%
Power Supply Output Type
Fixed
No. Of Outputs
3
Output Voltage
5V
Output Current
3.2A
Power Rating
42W
Input Voltage
90V AC To 264V AC / 120V DC To 370V DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
285-1663
ZPT40-51515N
Input Parameters
Models
ZPS40-3
ZPS60-3
ZPS40-5
ZPS60-5
ZPS40-9
ZPS60-9
ZPS40-12
ZPS60-12
ZPS40-15
ZPS60-15
ZPS40-24
ZPS60-24
ZPS40-28
ZPS60-28
ZPS40-30
ZPS60-30
ZPS40-36
ZPS60-36
ZPS40-48
ZPS60-48
ZPD40-512
ZPD40-524
ZPD40-5125N
ZPT40-51212N
ZPT40-51515N
ZPT40-52412N
ZPT40-5245N
ZPT40-52412p
ZPT40-3512N
Outputs
Output Parameters
Model
INRUSH CURRENT (132/264VAC)
RATED INPUT VOLTAGE RANGE
RATED INPUT CURRENT
INPUT FREQUENCY
ZPS40 , 40D/T & 60 Handbook
Output Voltage (V)
+12.0
+24.0
+12.0
+12.0
+15.0
+24.0
+24.0
+24.0
+12.0
+5.0
+5.0
+5.0
+5.0
-12.0
-15.0
+5.0
-12.0
+5.0
+5.0
+3.3
+5.0
-12.0
12.0
12.0
15.0
15.0
24.0
24.0
28.0
28.0
30.0
30.0
36.0
36.0
48.0
48.0
-5.0
-5.0
3.3
3.3
5.0
5.0
9.0
9.0
+5
25/50 (COLD START)
Output Current (A)
100 - 240V AC
47- 63Hz
1.5A
0.834
4.45
6.67
3.34
2.67
1.67
1.43
2.14
1.33
1.11
1.67
1.25
6.0
8.0
6.0
8.0
5.0
4.0
2.5
2.0
3.2
2.0
3.2
1.0
3.2
2.0
0.3
3.2
2.0
0.3
3.2
1.5
0.3
3.2
1.0
0.3
3.2
1.0
0.3
3.2
1.0
0.3
5.0
2.0
0.3
Servicing
These products are not customer serviceable. Repairs may only be carried out by Lambda UK or their
authorised agents. These products are not authorised for use as critical components in nuclear control
systems, life support systems or equipment for use in hazardous environments without the express
written approval of the Managing Director of Coutant Lambda Ltd.
Approval Limitations: Use in North America (AC units only)
When this product is used on 180VAC-250VAC mains with no neutral, connect the two live wires to
L(live) and N (neutral) terminals on the input connector. In this instance double pole fusing is required.
High Voltage Warning
Dangerous voltages present within the power supply. The proffesional installer must protect service
personnel from inadvertant contact with these dangerous voltages in the end equipment.
Safety Class of Protection
These products are designed for the following parameters : Material Group IIIa, Pollution Degree 2,
Overvoltage Category II, Class II, Indoor use as part of an overall equipment such that the product is
accessible to service engineers only.
EN55022-B, FCC Class B
Immunity
EN61000-4-2,EN61000-4-3,EN6100-4-4,EN61000-4-6, EN61000-4-8
to operate, whereby the output will cycle on and off or latch off. To reset for normal operation
simply adjust the potentiometer to reduce the ouput voltage to within it’s range or cycle the
input off then on if the unit has latched off.
Important safety instructions
UL60950 and CSA 60950 EN60950,Class II and CE (LVD) mark.
Conducted and Radiated EMI
Environmental parameters
Operation
Temperature:
Humidity:
Storage and Transportation
Temperature: -20
Humidity: 10% to 95% RH, non-condensing
Shock
<196.1 m/s
Vibration
23.52 m/s
Cooling
Convection
Output Limitations
Adjusting output voltage beyond the stated range may cause the overvoltage protection (OVP)
Safety approvals
2
2
(10-55H
(20G)
0 to +70
15,-24,-28,-30,-36,-40 >40
0 to +70
10 to 95% RH, non-condensing
0
C to +85
Z
): constant sweep 1 min X , Y, Z for one hour)
0
0
C (ZPS40-12,-15,-24,-28,-30,-36,-40 and ZPD40,ZPD40 and ZPS60-12,-
C (ZPS40-3,-5,-9 and ZPS60-3,-5,-9, >40
0
C
0
C -70
0
C derate at 2.5%/
0
0
C -70
C)
0
C derate at 2.5%/
0
C )
Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal.
For ZPS40 and ZPS60 output connector mates with Molex Housing 09-50-3041 and Molex 2878
series crimp terminal
For ZPS40D/T output connector mates with Molex Housing 09-50-3061 and Molex 2878 series
crimp terminal
Level of insulation
Dielectric Strength testing is carried out as follows:
Primary mains circuit to earth - 1.5kVAC.Primary mains circuits to secondary -3kVAC.
Outputs to each other and to earth are isolated to 500VDC.
Fuse
Internal fuse (F1): T2.2AL, 250V.
Input Connector
General installation instructions
The ZP family of component power supplies is designed for use within other equipment or
enclosures which restrict access to authorised competent personnel only. For safe installation and
operation of this product, carefully follow the instructions listed below.
i) These products are supplied open frame
ii) These products are Class II and must be installed in accordance with Class II requirements of
IE/EN/UL/CSAC60950.
iii) These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids
must not be used.
Output Connector
Fuse Information
(Neutral)
(Live)
ACL
ACN
Part Number 17164