HA15-0.9-AG POWER ONE, HA15-0.9-AG Datasheet

LINEAR SUPPLY 12V/.9A ADJ OUT

HA15-0.9-AG

Manufacturer Part Number
HA15-0.9-AG
Description
LINEAR SUPPLY 12V/.9A ADJ OUT
Manufacturer
POWER ONE
Series
Linearr
Type
Commercialr
Datasheets

Specifications of HA15-0.9-AG

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
10W
Applications
Commercial
Power Supply Type
Linear, Regulated (Open Frame)
Voltage - Input
100, 120, 220, 240VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 900mA
Size / Dimension
4.87" L x 4.00" W x 2.10" H (123.7mm x 101.6mm x 53.3mm)
Power (watts) - Rated
10W
Operating Temperature
0°C ~ 50°C
Efficiency
55%
Approvals
CE, CSA, EN, IEC, TUV, UL
Line Regulation
±0.05%
Load Regulation
±0.05%
Product
Linear
Commercial/medical
Commercial
Output Power Rating
876 W
Input Voltage
100 VAC to 264 VAC
Output Voltage (channel 1)
12 V
Output Current (channel 1)
0.9 A
Configuration
Open-Frame
Operation
Linear
Output
12 VDC @ 0.9 A
Primary Type
AC-DC
Voltage, Input
100 to 264 VAC
Voltage, Output
12 VDC
Worldwide Ac Input Capabilities
100/120/220/230/240 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2299
MCD10016 Rev. 1.2, 13-Nov-09
Description
Power-One produces the industry’s broadest selection of
Linear power supplies with output voltages from 5 volts
through 250 volts. Rugged technology and proven design
merge to create quiet, highly-regulated, dependable
OVERVOLTAGE PROTECTION OPTIONS
These optional overvoltage protection modules are offered for use with
Power-One’s Linear power supplies. Each is user adjustable from 6.4V to 34V.
OVP-12G
OVP-24G
Overvoltage Protection Options
Page 1 of 9
DC power.
The Linear power supplies are approved to domestic and
international regulatory standards, and are CE Marked to
the Low Voltage Directive (LVD).
OVP SELECTION GUIDE
NOTE:
CURRENT
MODELS
OUTPUT
OUTPUT
OUTPUT
SINGLE
TRIPLE
Features
• RoHS compatible for all six substances
• Worldwide AC Input Capabilities:
• ±0.05% Output Regulation
• Low Output Ripple
• UL, CSA, and TÜV Approvals
• Mean Time Before Failure (MTBF) in Excess of
• CE marked to Low Voltage Directive
• 100% Burn-In
• 2 Year Warranty
• Overvoltage Protection (OVP) Standard on 5V
DUAL
MODEL
PEAK
Linear Power Supplies Data Sheet
Outputs with factory built-in OVP are indicated in the Voltage/Current Rating
Chart for each model. OVP is not available for 48V through 250V models.
100/120/220/230/240 VAC
300,000 Hours
Single Outputs, Optional for other outputs
under 48V
AA,B,BB,CC
N,BAA,CBB
AA,BAA,D
CBB, 131
DBB,DCC
CASE SIZE
B,C,N,D
131
E,F
E
(1) OVP-12G protects both outputs
(1) OVP-24G protects both outputs
(1) OVP-12G protects any output
(1) OVP-12G protects both 12V
not provided with built-in OVP
www.power-one.com
through 15V outputs
OVP MODULES REQUIRED
(1) OVP-12G
(1) OVP-24G

Related parts for HA15-0.9-AG

HA15-0.9-AG Summary of contents

Page 1

Description Power-One produces the industry’s broadest selection of Linear power supplies with output voltages from 5 volts through 250 volts. Rugged technology and proven design merge to create quiet, highly-regulated, dependable OVERVOLTAGE PROTECTION OPTIONS These optional overvoltage protection modules are ...

Page 2

... HE5-18/OVP- F5-25/OVP- G5-35/OVP- CP197- 15Vout 12 0.9 HA15-0.9-AG 12 1.7 HB12-1.7-AG 12 3.4 HC12-3.4-AG 12 5.1 HN12-5.1-AG 12 6.8 HD12-6.8-AG 12 10.2 HE12-10.2- F15-15-AG 15* 0.9 HA15-0.9-AG 15 1.5 HB15-1.5- HC15-3-AG 15 4.5 HN15-4.5- HD15-6- HE15-9-AG 15* 15 F15-15- 28Vout 24 0.5 HA24-0.5-AG 24 1.2 HB24-1.2-AG 24 2.4 HC24-2.4-AG 24 3.6 HN24-3.6-AG 24 4.8 HD24-4.8- ...

Page 3

Unsigned output voltages are isolated and can be used as either + or - polarities. Nominal Max Vout* Amps 5V to 15Vout +5, –5 1.5, 1.5 +5, – +5, – 0.5 ...

Page 4

Unsigned output voltages are isolated and can be used as either + or - polarities. Nominal Max Vout* Amps Triple Output Models 24Vout +5, +12, –5* 2, 0.4, 0.4 5, +12, – 0.4 +5, +12, –5* ...

Page 5

Input Specifications PARAMETER CONDITIONS/DESCRIPTION Input Voltage - AC Jumper selectable, shipped factory configured for (Note 1, 2) 120VAC operation. All models must be externally fused for proper operation. Fuse ratings are marked on each unit. Consult factory for each unit’s ...

Page 6

Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Operating Temperature Derate output power linearly above 50° per °C. Storage Temperature Temperature Coefficient 0°C to 50°C (after 15 minute warm-up). 24 hours after warm-up. Shock Operating. Vibration Random vibration from ...

Page 7

MCD10016 Rev. 1.2, 13-Nov-09 Linear Power Supplies Data Sheet Page www.power-one.com ...

Page 8

MCD10016 Rev. 1.2, 13-Nov-09 Linear Power Supplies Data Sheet Page www.power-one.com ...

Page 9

NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of ...