GPFC125GG SL Power Electronics Manufacture of Condor/Ault Brands, GPFC125GG Datasheet

PWR SPLY QUAD +5+3.3,12,-12 125W

GPFC125GG

Manufacturer Part Number
GPFC125GG
Description
PWR SPLY QUAD +5+3.3,12,-12 125W
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GPFC125r
Datasheet

Specifications of GPFC125GG

Voltage - Output
3.3V, 5V, ±12V
Number Of Outputs
4
Power (watts)
125W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 9A
2nd Output
3.3 VDC @ 7A
3rd Output
12 VDC @ 2.5A
4th Output
-12 VDC @ 300mA
Size / Dimension
6" L x 3.5" W x 1.5" H (152.4mm x 88.9mm x 38.1mm)
Power (watts) - Rated
125W
Operating Temperature
0°C ~ 50°C
Efficiency
85%
Approvals
CE, CSA, EN, IEC, UL
Line Regulation
1%
Load Regulation
1%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
271-2348
52
SPECIFICATIONS:
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current 2A at 90 Vac, 60 Hz with full rated load.
Input current harmonic content meets the requirements of
IEC1000-3-2. Active circuitry provides high power factor as
listed at .96 min., .99 typical. All data taken with full output
loading.
DC Output Power
125 W with 150 LFM of air, 50 W convection cooled, 80 W
convection cooled with unit mounted to min. 12 x 12 x .125 in.
thick aluminim plate. Peak ratings are for 60 s maximum
duration, 10% duty cycle. With optional cover installed,125 W,
200 LFM airflow is required(-C suffix).
Inrush Current
Inrush 240 Vac is less than 37 A, averaged over the first ac
half-cycle under cold start conditions. Limiting provided by
internal thermistors.
Input Protection
Internal ac fuse provided on all models. Fuse does not blow on
overload or short circuit — fuse blows only if a catastrophic
failure occurs in the unit.
Efficiency
72 to 85% at full rated load. Depending upon model and load
distribution.
Minimum Load
Supply will function with no load on any output. To maintain
regulation with full load on V2, 3 and 4 output V1 requires a
minimum load of (2A + V4 current). Lower minimum load may be
obtained if less then full load is drawn from auxiliary outputs.
Overload Protection
Fully protected against short circuit and output overload. Total
output power limited to approximately 150 Watts. Cycling type
limits on output 1, 2 & 3, linear fold back on output 4. Recovery
after fault is automatic.
Overvoltage Protection
Built in on all models - See Output table for individual model
output limits.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode.
Transient Response
500 ms typical response time for return to within 0.5% of final
value for a 50% load step change, ∆i/∆t< 0.2 A ms. Maximum
voltage deviation is 3.5%.
Temperature Coefficient
0.03% / °C typical on all outputs.
GPFC125
125 Watt Global Performance Switchers
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
Commercial/GPFM125 Medical
FEATURES:
• Compact 125 watt multiple output
• Power density of 4 watts per cubic inch
• Power Factor Correction to meet EN61000-3-2
• Small package 6.00 x 3.5 x 1.5 inches
• Conducted EMI exceeds FCC Class B and CISPR 22
• Commercial approved to UL1950, IEC950, CSA22.2
• Medical approved to UL2601-1, IEC601-1, CSA22.2
Remote Sense
Provided as a standard feature on V1 of all models.
Temperature Range
0 to 50 °C at full rated output power. For operation above 50 °C,
derate output power and current by 2.5 % per °C.
Altitude
Shock and Vibration
All models are designed to meet the following specifications;
Random Vibration -
Operating: 0.003 g
Non-Operating: 0.026 g
Shock -
Operating: Half-sine, 20 g
Non-Operating: Half-sine, 40 g
EMI/EMC Compliance
All models include built-in EMI filtering to meet the EMC
requirements below.
EMI SPECIFICATIONS
Conducted Emissions-GPFC125
Conducted Emissions-GPFM125
Static Discharge
RF Field Susceptibility
Fast Transients / Bursts
Surge Susceptibility
Conducted RF Susceptibility
Voltage Sags & Surges
Line Frequency Harmonics
Commercial Safety Approvals
All models are approved to UL1950, CSA22.2 No. 950-95,
IEC950, EN60950. CB certificate available. Exceeds FCC and
CISPR22 Class B conducted emissions requirement
Medical Safety Approvals
All models are Certified to be in compliance with the applicable
requirements of UL2601, CSA 22.2 No. 601.1-M90, IEC 601-1
(1988), EN 60601-1: 1990. CB certificate available.
Leakage Current
The maximum leakage current is as follows:
Test Condition
132 Vac @ 60 Hz input
264 Vac @ 50 Hz input
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
No. 950 and EN60950.
No. 601.1, EN60601-1
Operating:
Non-Operating
marked to LVD
2
-500 to 10,000 ft. MSL
/Hz, 1.5 g
-500 to 40,000 ft MSL
2
/Hz, 5.0 g
pk
, 10 ms, 3 axes, 6 shocks total
Normal
rms
130 µA
COMPLIANCE LEVEL
EN55022, Class B; FCC Class B
EN55011,Class B; FCC Class B
EN61000-4-2, 6 kV contact 8 kV air
EN61000-4-3, 3V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-4-6, 3V
EN61000-4-11
EN61000-3-2 Class A
70 µA
pk
overall, 3 axes, 10 min. / axis
, 10 ms, 3 axes, 6 shocks total
rms
overall, 3 axes, 1 hr. / axis
Single Fault
120 µA
240 µA