LPS254-CF Emerson Network Power, LPS254-CF Datasheet - Page 2

PWR SUPPLY 250W 12-24V CVR/FAN

LPS254-CF

Manufacturer Part Number
LPS254-CF
Description
PWR SUPPLY 250W 12-24V CVR/FAN
Manufacturer
Emerson Network Power
Series
LPS250r
Type
Enclosedr
Datasheet

Specifications of LPS254-CF

Voltage - Output
15V
Number Of Outputs
1
Power (watts)
250W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
15 VDC @ 16.7A
Size / Dimension
9" L x 5" W x 3.0" H (228.6mm x 127mm x 76.2mm)
Power (watts) - Rated
250W
Operating Temperature
0°C ~ 50°C
Efficiency
75%
Approvals
CB, CE, CSA, NEMKO, UL, VDE
Line Regulation
±2%
Load Regulation
±2%
Product
Switching
Output Power Rating
250 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 300 VDC
Output Voltage (channel 1)
15 V
Output Current (channel 1)
0.5 A
Mounting Style
Rack
Dimensions
9 in L x 5 in W x 2 in H
Open Frame/enclosed
Enclosed
Output Current (max)
16.7A
Output Voltage
15V
Output Power (max)
250W
Input Frequency
47 to 440Hz
Screening Level
Commercial
Product Depth (mm)
127mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Pin Count
17
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1212
LPS254-CF
Logic Control
Environmental Specifications
Power failure:
Remote on/off:
DC - OK:
Remote sense:
Operating temperature:
Storage temperature:
Temperature coefficient: ± 0.4% per °C
Electromagnetic
susceptibility:
Humidity:
Vibration:
MTBF demonstrated:
Ordering Information
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. If optional CF or CEF fans are not used, 30CFM forced air cooling needs to be provided and is required through the length of the power supply.
5. O utput voltage adjustment requires a minimum load.
6. Remote inhibit resets OVP latch
Note: -CF suffix added to the model number indicates cover with top fan. -CEF suffix added to the model number indicates cover with dual end
mounted fan cover and AC inlet.
Model Number
Not convection rated.
LPS252-C
LPS253-C
LPS254-C
LPS255-C
Output Voltage Minimum Load
24 V (24 -48 V)
12 V (6 - 12) V
15 (12 - 24 V)
5 V (3 - 6 V)
0° to 50 °C ambient;
derate each output at 2.5% per degree from 50° to 70 °C
-40 °C to +85 °C
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95%
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G
peak 5 Hz to 500 Hz, operational
> 550,000 hours at full load and 25 °C ambient conditions
TTL Logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 ms before loss of
regulation
Requires an external contact (N.O or N.C) to inhibit outputs
TTL logic goes high 50-150 msec after the output. It goes low when there is loss of
regulation.
Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse
connection protected
1.50 A
0.63 A
0.50 A
0.32 A
Maximum Load with
30CFM Forced Air
16.7 A
10.4 A
50 A
21 A
Peak Load 1 Regulation 2 Ripple P/P (PARD) 3
12.5 A
60 A
25 A
20 A
±2%
±2%
±2%
±2%
Embedded Power for
Business-Critical Continuity
120 mV
150 mV
240 mV
50 mV
Rev. 2.16.09_158
LPS250 Series
2 of 3