CSS6512 TDK Corporation, CSS6512 Datasheet

PWR SUP IND MEDICAL 12V 5A 60W

CSS6512

Manufacturer Part Number
CSS6512
Description
PWR SUP IND MEDICAL 12V 5A 60W
Manufacturer
TDK Corporation
Series
CSS65r
Datasheets

Specifications of CSS6512

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
65W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 5A
Size / Dimension
4" L x 2" W x 1.18" H (101.6mm x 50.8mm x 29.97mm)
Power (watts) - Rated
60W
Operating Temperature
0°C ~ 70°C
Efficiency
86%
Approvals
EN, IEC, UL
Line Regulation
±3%
Load Regulation
±3%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
285-1854
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Input Voltage range
Inrush Current
Input Current (115/230VAC)
Leakage Current
Hold Up Time (Typ)
Temperature Coefficient
Adjustment Range
Remote Sense
Minimum Load
Regulation
Ripple & Noise
Short Circuit Protection
Overvoltage Protection
Efficiency
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (WxLxH)
Warranty
Industry standard footprint
Wide Range AC Input
Dual input fuses
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-526-2324
uA
ms
°C
°C
°C
in
yr
A
A
A
%
%
%
V
V
g
-
-
-
-
-
-
-
-
-
-
-
-
5V: ±5%, 12-24V: ±3%, 36-48V: ±2% (10 - 100% load change, 100-240VAC line change)
Input to Ground 1.5kVAC, Input to Output 4kVAC, Output to Ground 500VDC for 1 min.
2 x 4" 40 to 65W AC-DC Medical Power Supplies
CSS65 Series
23.52m/s
<40A maximum at 115VAC input, 25oC ambient cold start
0 to +70°C derate linearly to 50% load from 50 to 70°C
>20M at 25C & 70%RH, Output to Ground 500VDC
2 x 4 x 1.18" (including underside components)
2
90 - 264VAC (47 - 63Hz) or 120 - 370VDC
(10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
110 - 150% of nominal (Automatic Reset)
Benefit
UL60601-1, EN60601-1, IEC60601-1
Medical
Gaming
Test and Measurement
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Availability to second source
Global Operation
Easier system compliance
Wide Range AC Input
Low profile, Industry Standard Footprint
Global Safety Agency Compliance
Remote Sense
86% typical (115VAC Input)
Continuous - hiccup mode
EN55011-B, FCC Class B
<250uA 264VAC 63Hz
10ms at 115VAC input
< 196.1 m/s
EN60601-1-2
-10 to +70°C
20 - 95% RH
±0.05%/°C
Convection
Two Years
CSS65
None
None
200g
2 / 1
Yes
1%
2
(20G)
23

Related parts for CSS6512

CSS6512 Summary of contents

Page 1

Feature Industry standard footprint Wide Range AC Input Dual input fuses ...

Page 2

Maximum Model Output (V) Output (A) CSS65-5 5 CSS65-12 12 CSS65-15 15 ...

Related keywords