BLP55-3300G POWER ONE, BLP55-3300G Datasheet

PWR SUP 55W 3.3V,5V,12V OUT TRPL

BLP55-3300G

Manufacturer Part Number
BLP55-3300G
Description
PWR SUP 55W 3.3V,5V,12V OUT TRPL
Manufacturer
POWER ONE
Series
BLP55r
Type
Switchingr
Datasheets

Specifications of BLP55-3300G

Voltage - Output
3.3V, 5V, 12V
Number Of Outputs
3
Power (watts)
55W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
100 ~ 250VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 7A
2nd Output
5 VDC @ 4A
3rd Output
12 VDC @ 1A
Size / Dimension
5" L x 3" W x 1.23" H (127mm x 76.2mm x 31.2mm)
Power (watts) - Rated
55W
Operating Temperature
0°C ~ 70°C
Efficiency
70%
Approvals
CB, CE, CSA, EN, IEC, UL
Line Regulation
±2.5%, ±5%
Load Regulation
±2.5%, ±5%
Input Voltage
85 to 264 V
Output Voltage
3.3|5|12 V
Maximum Current Rating
1(rms)(Typ) A
Maximum Output Current
4|2|0.5 A
Maximum Output Power
25 W
Input Frequency
47 to 63 Hz
Product
Switching
Commercial/medical
Commercial
Output Power Rating
17 W
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
5 A
Output Voltage (channel 2)
5 V
Output Current (channel 2)
2.5 A
Output Voltage (channel 3)
12 V
Output Current (channel 3)
0.7 A
Mounting Style
Chassis
Dimensions
127 mm L x 76.2 mm W x 31.2 mm H
Open Frame/enclosed
Open Frame
Brand/series
BLP55 Series
Configuration
Open-Frame
Operation
Switching
Output
+3.3 VDC @ 4 A, +5 VDC @ 2 A, +12 VDC @ 0.5 A
Power, Output
55 W
Primary Type
AC-DC
Special Features
Remote Sense
Voltage, Input
100 to 250 VAC
Voltage, Output
+3.3, +5, +12 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2268
Ordering Information:
103354D Rev AB1, 06-FEB-09
Description
The BLP55 Series’ economical and compact construction provides single or three-output ac-dc power conversion to
meet the requirements of networking and data communications systems, as well as commercial and industrial
configurations.
The BLP55 is rated for convection, as well as forced-air cooling. Full output power is available with external
forced-air cooling. Other features include main-output remote sense and an internal EMI filter.
Single Output Model Selection
BLP55-1005
BLP55-1012
BLP55-1024
Triple Output Model Selection
BLP55-3000
BLP55-3300
NOTES:
OPTIONS
RoHS lead solder exempt
RoHS compliant for all 6 substances
MODEL
MODEL
1
2
3
4
on 0.25” standoffs. Recommended airflow direction is from the AC side to the DC side.
10 CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5” x 1.6” cross-sectional area) with power supply mounted
Peak current duration for less than 30 Sec with a maximum duty cycle of 10%.
At 25 °C ambient including voltage set point tolerance, line, and load regulation.
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, and bypass capacitors of 10 μF and 0.1 μF.
NOMINAL OUTPUT
NOMINAL OUTPUT
VOLTAGE (VDC)
VOLTAGE (VDC)
5V
12V
24V
+5V
+12V
-12V
+3.3V
+5V
+12V
MIN-MAXIMUM OUTPUT
CURRENT, CONVECTION
MIN-MAXIMUM OUTPUT
CURRENT, CONVECTION
0.0 to 0.5A
0.0 to 0.5A
0 to 3.3A
0 to 1.6A
0.4 to 4A
0.2 to 2A
0.5 to 4A
0.0 to 2A
0 to 8A
No RoHS character required.
Add “G” as the last character of the part number.
SUFFIXES TO ADD TO PART NUMBER
MIN-MAXIMUM OUTPUT
MIN-MAXIMUM OUTPUT
0.2 to 2.5A
0.0 to 0.7A
0.0 to 2.5A
0.0 to 0.7A
Page 1 of 6
CURRENT 1
0 to 4.5A
0 to 2.3A
CURRENT 1
0.5 to 5A
0.5 to 5A
0 to 11A
Features
• RoHS lead-free solder and lead-solder-exempted
• Industry-standard 3” x 5” footprint
• Main output remote sense
• CE marked to Low Voltage Directive
• Compliance to EN61000-4-2/-3/-4/-5/-6/-8
products are available
BLP55 AC-DC Series Data Sheet
PEAK OUTPUT
PEAK OUTPUT
CURRENT 2
CURRENT 2
2.5A
12A
5A
7A
4A
7A
4A
1A
1
REGULATION % 3
REGULATION % 3
TOTAL
TOTAL
±2.5
±2.5
±2
±2
±2
±2
±5
±5
±5
www.power-one.com
55 Watts
RIPPLE & NOISE
RIPPLE & NOISE
%p-p 4
%p-p 4
1
1
1
1
1
1
1
1
1

Related parts for BLP55-3300G

BLP55-3300G Summary of contents

Page 1

... The BLP55 is rated for convection, as well as forced-air cooling. Full output power is available with external forced-air cooling. Other features include main-output remote sense and an internal EMI filter. Single Output Model Selection ...

Page 2

... Overvoltage Protection Main output. Short Circuit Protection Fully-protected against output short circuit. 103354D Rev AB1, 06-FEB-09 BLP55 AC-DC Series Data Sheet Vin = 115 VAC, Max Power, 25 °C. Vin = 230VAC, Max Power, 25 °C. See Model Selection Table See Model Selection Table -5%, +10% 3 ...

Page 3

... CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5” x 1.6” cross-sectional area) with power supply mounted NOTES: on 0.25” standoffs. Recommended airflow direction is from the AC side to the DC side. 103354D Rev AB1, 06-FEB-09 BLP55 AC-DC Series Data Sheet on completed assemblies. Conducted: Conducted: ...

Page 4

... Figure 1. BLP55-3000 Typical Quasi-Regulation Figure 2. BLP55-3000 5V Output Voltage vs. 12V load 5.2 5.1 5 4.9 4.8 4.7 4.6 4.5 0 103354D Rev AB1, 06-FEB-09 Performance for +12V Output 0.5 1 1.5 2 12V Output Current (Am ps) 0.5 1 1.5 2 12V Load in Amps Page BLP55 AC-DC Series Data Sheet ...

Page 5

... SAFETY GROUND CONNECTION POINT #1 SIDE VIEW 1.23 (31.2) PRINTED CIRCUIT BOARD NOTE: This is an outline drawing only. The detailed location of components is not shown. 103354D Rev AB1, 06-FEB-09 BLP55 AC-DC Series Data Sheet 5.00 (127.0) 4.55 (115.6) SECONDARY GROUND CN3 - REMOTE SENSE PIN #1 CONNECTOR (APPROX ...

Page 6

... RECOMMENDED MATING CONNECTORS HOUSING CN1 MOLEX 09-50-8031 LEOCO 3940S030000 CN2 MOLEX 09-50-8061 LEOCO 3940S060000 CN3 MOLEX 22-01-3027 LEOCO 2530S020000 Page BLP55 AC-DC Series Data Sheet CN1 - AC CONN. PIN 1 NEUTRAL PIN 2 MISSING PIN PIN 3 LINE CN2 - DC CON Ø 0.16 (4 PL) (4.1) PIN 1 ...

Related keywords