GPFC160-12G SL Power Electronics Manufacture of Condor/Ault Brands, GPFC160-12G Datasheet

PWR SPLY PFC 160W 12V 11.7A

GPFC160-12G

Manufacturer Part Number
GPFC160-12G
Description
PWR SPLY PFC 160W 12V 11.7A
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GPFC160r
Datasheet

Specifications of GPFC160-12G

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
160W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 11.7A
Size / Dimension
7" L x 4.5" W x 1.7" H (177.8mm x 114.3mm x 43.2mm)
Power (watts) - Rated
160W
Operating Temperature
0°C ~ 50°C
Approvals
CE, EN, IEC, UL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
271-2349
62
SPECIFICATIONS:
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current 2.3 A at 90 Vac, 60 Hz with full
rated load. Input current harmonic content meets the
requirements of IEC1000-3-2.
Hold-upTime
25 ms minimum from loss of ac input at full load, nominal
line (115 Vac).
Output Power
Total regulation is the maximum deviation from the
nominal voltage for all steady-state loading conditions.
Each individual output is to be used within its specified
limits of that output. Peak ratings are for 60 s maximum
duration, 10% duty cycle.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit.
Recovery after fault is automatic.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential
mode. Measured with noise probe directly across output
terminals of the power supply.
Transient Response
500 ms typical response time for return to within 0.5% of
final value for a 50% load step change, i/ t< 0.2 A/ms.
Maximum voltage deviation is 3.5%.
Remote Sense
Provided as a standard feature. Capable of compensating
for 0.25 V total of cabling losses.
Overvoltage Protection
Built in on all models. OVP crowbar reduces output
voltage below nominal rating in less than 50 ms.
Voltage Adjustment
Main output ±5%.
GPFC160 Commercial
160 Watt Global Performance Switchers
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
FEATURES:
• 3.0 watts/cu.in. power density
• Compact size (4.5" x 7.0" x 1.7"; meets 1U height)
• Power factor corrected to IEC 1000-3-2; Class A
• Less than 300 µA leakage
• EMI compliance to CISPR22, FCC Class B
• Commercial Approved to UL1950, IEC950, EN60950
• 2-year warranty
Input Protection
Internal ac fuse provided on all models. Fuse does not
blow on overload or short circuit—fuse blows only if
catastrophic failure occurs in the unit.
Inrush Current
Inrush 240 Vac is less than 37 A, averaged over the first
ac half-cycle under cold start conditions. Limiting pro-
vided by internal thermistors.
Fan Output
An additional 12 Vdc, 250 mA output suitable for power-
ing a dc fan is included in all models. The output is
protected by an internal PTC in the event of an overload.
Thermal Shutdown
Provided as a standard feature. Designed to protect the
unit from prolonged over temperature.
Power Fail
TTL or CMOS compatible output goes low (<0.5 V) 8 ms
before output voltage drops more than 4% below nominal
voltage upon loss of ac power. The signal is factory set to
trip when input power can no longer sustain the output.
Temperature Coefficient
0.03%/°C typical on all outputs.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Commercial Safety
Approved to UL1950, CSA22.2 950, IEC950, and
EN60950. UL file #E135803 commercial; CSA #LR46516.
The output(s) are intended for safety earthed Signal
Output and Intermediate Circuits only. All dc outputs are
SELV under normal and single fault conditions.
and CSA 22.2 No. 950
marked to LVD
EN61000-4-5, 1 kV diff., 2 kV com.
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-3, 3 V/meter

Related parts for GPFC160-12G

GPFC160-12G Summary of contents

Page 1

... GPFC160 Commercial 160 Watt Global Performance Switchers SPECIFICATIONS: Ac Input 85-264 Vac, 47-63 Hz single phase. Input Current Maximum input current 2 Vac with full rated load. Input current harmonic content meets the requirements of IEC1000-3-2. Hold-upTime 25 ms minimum from loss of ac input at full load, nominal line (115 Vac) ...

Page 2

... GPFC160 Commercial Output rating with unrestricted convection cooling. B. Output rating with 26 cfm airflow. GPFC160 MECHANICAL SPECIFICATIONS Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com 160 Watt Single Output Units should be allowed to warm up/operate under non-condensing conditions before application of power ...