POWER SUPPLY CPCI AC-DC 200W

CPCI200A-1C

Manufacturer Part NumberCPCI200A-1C
DescriptionPOWER SUPPLY CPCI AC-DC 200W
ManufacturerMurata Power Solutions Inc
CPCI200A-1C datasheet
 


Specifications of CPCI200A-1C

Power Supply TypeSwitching (Closed Frame)Voltage - Output3.3V, 5V, ±12V
Number Of Outputs4Power (watts)200W
ApplicationsCommercialVoltage - Input90 ~ 264VAC
Mounting TypeCompact PCI®1st Output5 VDC @ 25A
2nd Output3.3 VDC @ 30A3rd Output12 VDC @ 5A
4th Output-12 VDC @ 1ASize / Dimension6.68" L x 3.94" W x 0.8" H (169.6mm x 100mm x 20.3mm)
Power (watts) - Rated200WOperating Temperature0°C ~ 50°C
Efficiency80%ApprovalsCE, CSA, SELV, UL, VDE
Power Supply Output TypeFixedNo. Of Output Channels4
Input Frequency63HzOutput Voltage5V
Output Current25APower Rating200W
Input Voltage90VAC To 264VACSupplyRoHS Compliant
Output Power Rating125 WOutput Voltage (channel 1)5 V
Output Current (channel 1)25 AOutput Voltage (channel 2)+ 3.3 V
Output Current (channel 2)30 AOutput Voltage (channel 3)+ 12 V
Output Current (channel 3)5 AMounting StyleRack
Dimensions6.4 in L x 3.94 in W x 0.8 in HNo. Of Outputs4
Rohs CompliantYesLead Free Status / RoHS StatusLead free / RoHS Compliant
Other names811-1739  
1
Page 1
2
Page 2
3
Page 3
4
Page 4
Page 1/4

Download datasheet (185Kb)Embed
Next
NOT RECOMMENDED
FOR NEW DESIGNS
FEATURES
3Ux4HP package
200W power at 0-50ºC
PICMG 2.11 Compliant
Widerange 90-264VAC Input
Active power factor correction to EN61000-3-2
Class A conducted EMI performance
47-pin I/O Connector
80% efficiency
Full power with just 250lfm airflow
Hot-swap capable
DESCRIPTION
The cPCI200A-1C is a high-reliability, 200W, 3Ux4HP
CompactPCI™ power supply developed for chassis’
with airflows as low as 250lfm. The use of resonant
conversion and ORing FETs yields high efficiency which
consequently permits packaging of this product in a
compact, single card slot format (4HP).
The ORing FETs, current sharing, and synchronous start
control allow the cPCI200A-1C to be operated in N+n
parallel-redundant configurations. The low leakage
current permits redundant configurations to comply
with safety standards. The unit is capable of hot-swap
performance to support high-availability enterprise
applications.
With a widerange input of 90-264VAC, safety
agency approvals to UL60950 and EN60950, EMI
compliance to Class A FCC and EN55022 standards,
the cPCI200A-1C was designed with globally-deployed
systems in mind. Additional features include remote
sense compensation, unit enable control (EN#), output
inhibit control (INH#), output fault signal (FAL#), and
thermal warning signal (DEG#). LEDs are provided for
visual indication of input power presence and output
fault condition.
www.murata-ps.com
SELECTION GUIDE
Model Number
Power
5V
CPCI200A-1C
200W
25A
INPUT CHARACTERISTICS
Parameter
Conditions
Input Operating Voltage
Input Frequency
Input Current
Power Factor
Inrush Current
240Vac
Leakage Current
240VAC, 63Hz
OUTPUT CHARACTERISTICS
Output
Nominal Voltage
2
V1
+5.0Vdc
2
V2
+3.3Vdc
V3
+12Vdc
V4
-12Vdc
Parameter
Conditions
Temperature Coefficient
PARD (V1 & V2)
20MHz bandwidth
PARD (V3 & V4)
20MHz bandwidth
Output Power
50ºC, 250lfm airflow
Output Power
70ºC, 250lfm airflow
ΔV, 50% load step
Transient Response
Settling time
Over-Voltage Protection
V1, V2, & V3
Minimum Load
4
V1 or V2
Output Holdup Time
Full load, low line
5
Remote Sense Compensation
V1, V2, & V3
Current Share Tolerance
V1-V3; I
Pri-Sec
Isolation
Pri-Chassis
Sec-Chassis
Notes:
1. Total regulation includes line, load, and cross regulation.
2. Maximum combined power from V1 & V2 not to exceed 125W.
3. Minimum load requirement of 1A may be fulfilled on either V1 or V2, but need not be applied to both.
The unit will operate with less than the stated minimum, but full load on V3 & V4 is only achievable with
the minimum load requirement met on V1 and/or V2.
4. Minimum load is for a single unit; units operated in parallel may require additional load to achieve full
power on outputs V3 and V4.
5. Unit automatically reverts to local sensing if the sense lines are opened. Unit is protected against shorted
or reversed sense lines.
cPCI200A-1C Series
200W 3Ux4HP AC/DC CompactPCI™
Output Current
 
3.3V
12V
-12V
For full details go to
www.murata-ps.com/rohs
30A
5A
1A
Yes
Min
Typ
90
47
0.95
0.98
1
Output Current
Total Regulation
Min
Max
3
1A
25A
3
1 A
30A
0A
5A
0A
1A
Min
Typ
Max
0.02
50
120
180
0
200
0
100
±5
500
125
135
1
12
16
250
>25%
10
o
3
1.5
500
cPCI200A-1C Series
Rev D
02/2008
Yes
Max
Units
264
Vac
63
Hz
3.5
A
rms
0.99
35
A
pk
mA
1
+4/-2%
+4/-2%
±4%
±4%
Units
%/ºC
mV
p-p
mV
p-p
W
W
%V
nom
μsec
%V
nom
A
msec
mV
%
kVac
kVac
Vac
Page 1 of 4

CPCI200A-1C Summary of contents

  • Page 1

    ... The ORing FETs, current sharing, and synchronous start control allow the cPCI200A- operated in N+n parallel-redundant configurations. The low leakage current permits redundant configurations to comply with safety standards. The unit is capable of hot-swap performance to support high-availability enterprise applications ...

  • Page 2

    ... Typ Max 79 81 100 130 200 620 Inception Min Typ Max 100 3 4 125 135 Min Typ Max 0 50 -40 125 -200 10000 -200 50000 cPCI200A-1C Series Rev D 02/2008 Units % kHz kHz khrs g Units ºC A rms A rms %V nom Units ºC º Page ...

  • Page 3

    ... LVD Directive; self-certified EN Directive 2002/95/EC; self-certified (see Selection Guide for specific model compliances) Certified MIL-STD-883F, Method 2007.3, Test Condition A, pending MIL-STD-883F, Method 2002.4, Test Condition A, pending cPCI200A-1C Series 200W 3Ux4HP AC/DC CompactPCI™ cPCI200A-1C Series Rev D 02/2008 Page ...

  • Page 4

    ... Pin numbers correspond to the female backpane connector. 2. “L” denotes long pin length (first mate, last break) “M” denotes medium pin length “S” denotes short pin length (last mate, first break) 3. This function not used in the CPCI200A-1C Series. ISO9001 CERTIFIED Murata Power Solutions, Inc. ...