CPCI200A-1C Murata Power Solutions Inc, CPCI200A-1C Datasheet - Page 2

POWER SUPPLY CPCI AC-DC 200W

CPCI200A-1C

Manufacturer Part Number
CPCI200A-1C
Description
POWER SUPPLY CPCI AC-DC 200W
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of CPCI200A-1C

Power Supply Type
Switching (Closed Frame)
Voltage - Output
3.3V, 5V, ±12V
Number Of Outputs
4
Power (watts)
200W
Applications
Commercial
Voltage - Input
90 ~ 264VAC
Mounting Type
Compact PCI®
1st Output
5 VDC @ 25A
2nd Output
3.3 VDC @ 30A
3rd Output
12 VDC @ 5A
4th Output
-12 VDC @ 1A
Size / Dimension
6.68" L x 3.94" W x 0.8" H (169.6mm x 100mm x 20.3mm)
Power (watts) - Rated
200W
Operating Temperature
0°C ~ 50°C
Efficiency
80%
Approvals
CE, CSA, SELV, UL, VDE
Power Supply Output Type
Fixed
No. Of Output Channels
4
Input Frequency
63Hz
Output Voltage
5V
Output Current
25A
Power Rating
200W
Input Voltage
90VAC To 264VAC
Supply
RoHS Compliant
Output Power Rating
125 W
Output Voltage (channel 1)
5 V
Output Current (channel 1)
25 A
Output Voltage (channel 2)
+ 3.3 V
Output Current (channel 2)
30 A
Output Voltage (channel 3)
+ 12 V
Output Current (channel 3)
5 A
Mounting Style
Rack
Dimensions
6.4 in L x 3.94 in W x 0.8 in H
No. Of Outputs
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
811-1739
ENVIRONMENTAL CHARACTERISTICS
Parameter
Ambient Operating Temperature
Ambient Storage Temperature
Operating Humidity
Storage Humidity
Altitude
GENERAL CHARACTERISTICS
Parameter
Efficiency
Switching Frequency
MTBF
Weight
PROTECTION
Parameter
Thermal Shutdown
Input Current Limit
Input Protection
Over-voltage Protection
Parameter
Output Overload Protection
Hot-Swap Capability
Output Fault Isolation
STATUS & CONTROL SIGNALS & INDICATORS
Name
Enable (EN#)
Output Inhibit (INH#)
Output Fault (FAL#)
Remote Sense (RS+, RS-)
Thermal Warning (DEG#)
Sync Start (Sync)
Fault Indicator LED
Power Present Indicator LED
www.murata-ps.com
Conditions/Response
Automatic recovery upon restoration to operational temperatures
Internal line fuse; Schurter 0034.6981 or equivalent
V1, V2, & V3
Conditions/Response
Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition.
Overload response for outputs V1-V3 is constant-current mode. Overload response for V4 is foldback; hiccup mode in response to a hard short.
Design Verification Testing (DVT) confirms that voltage excursions on the output buses resulting from insertion/extraction events do not exceed
the specified maximum of 5%. However, routing of power and signal lines in the mating backplane is critical to minimization of such excursions.
In addition, performance can be critically affected by load characteristics including resistance, negative resistance, and reactive components.
While the control loop responses have been designed for optimum hot-swap performance over a wide range of load characteristics, there may be in-
stances where the voltage excursions exceed published specifications. In such cases, the control loop responses can be modified to perform optimally.
Output isolation devises are present in all outputs to isolate faults within a failed power supply.
Description
Short pin on connector will enable the outputs when the mating pin is grounded. Supply will not power up until this pin is engaged
to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector.
Secondary referenced; active low, TTL compatible. Logic “0” or short circuit to output return inhibits all outputs.
Secondary referenced; TTL compatible. Logic “0” denotes that one of the output voltages has fallen below the lower regulation limit.
Connection of the sense leads across the load at the desired point of regulation will compensate for voltage distribution drops up to 250mV
between the output terminals of the power supply and the point of connection. The output is protected against shorted or open leads. Each
of the Remote Sense lines must be terminated to the corresponding output and return lines in order guarantee all performance specifications.
Secondary referenced; TTL compatible. Logic “0” denotes a thermal warning; nominally, 10ºC prior to thermal shutdown.
Interconnection of the sync start leads between cPCI200A-1 units connected in parallel permits synchronous starting to support loads
that exceed the maximum for a single unit. Pin 35 (V1 Share) is used for the synchronous start function.
An LED will illuminate red if the output voltages are not within specification, coincident with assertion of the FAL# signal. This LED
will also illuminate amber if the output is inhibited.
A green LED will be illuminated when the input voltage is present and above the minimum requirement.
Conditions
Non-condensing
Non-condensing
Operating. De-rate operating ambient temperature by 2Cº per 1000ft above 5000ft.
Storage
Conditions
Full load, 240Vac
PFC Converter
Main Converter
Calculated per Telcordia SR-332, Issue 1, 50ºC, 250lfm, ground benign
Unpackaged
200W 3Ux4HP AC/DC CompactPCI™
cPCI200A-1C Series
cPCI200A-1C Series
Min
-200
-200
Min
-40
10
0
5
Rev D
200
Min
Inception
100
125
Typ
3
Typ
100
130
620
02/2008
Typ
79
10000
50000
Max
Max
135
125
50
90
90
4
Max
81
Page 2 of 4
%V
Units
Units
A
A
Units
khrs
ºC
ºC
ºC
%
%
kHz
kHz
ft
ft
rms
rms
%
nom
g