D1U-W-2000-48-HB2C Murata Power Solutions Inc, D1U-W-2000-48-HB2C Datasheet
D1U-W-2000-48-HB2C
Specifications of D1U-W-2000-48-HB2C
Related parts for D1U-W-2000-48-HB2C
D1U-W-2000-48-HB2C Summary of contents
Page 1
... Two Power Shelves can operate in parallel by an optional Shelf-to-Shelf cable, doubling the power output to the maximum capability of 12kW for two 48V power shelves. SELECTION GUIDE Power Output Part Number High Line AC D1U-W-2000-48-HC2C 2000W D1U-W-2000-48-HA2C 2000W D1U-W-2000-48-HB2C 2000W Part Number Description S1U-3X-16-A-48-RC Power shelf for 48V D1U INPUT CHARACTERISTICS Parameter Conditions Low Line AC ...
Page 2
... Latching 44 Latching 13 Latching 2.5 Latching 3.57 Latching 6.5 Latching 5.6 Latching 5 Typ. Max. Units 240 mV 90.6 % 1.5 s 150 ms ±2700 ±165 mV ±250 ±600 ± Typ. Max. Units 70 ° Khrs Khrs 60 dB LpAm Typ. Max. Units 65 ° 4. email: toronto@murata-ps.com 08 Apr 2010 CPS_D1U-W-2000-48-Hx.C08 Page ...
Page 3
... IEC/EN 61000-4-11 Typ. Max. Units Vrms Vrms Criteria Class A, 6dB margin Class A, 6dB margin 4kV contact discharge 8kV operational air discharge 15kV non-operational air discharge 1kV/2kV, Performance Criteria B 3 Vac, 80% AM, 1kHz, Performance Criteria A 3 A/m email: toronto@murata-ps.com 08 Apr 2010 CPS_D1U-W-2000-48-Hx.C08 Page ...
Page 4
... Vsb) N/A <0.7V (active, PS:On >2.1V (open, or Vsb <0.7V (active, PS:On Vsb Vsb >2.1V, < Vsb ±1 mA <0.8V >2.1V, <Vsb ±1 mA <0.8V >2.1V, <Vsb ±1 mA <0.8V 2 Solder Straight Right Angle 36-0440026-0 51762-10602000ABLF TBD email: toronto@murata-ps.com 08 Apr 2010 CPS_D1U-W-2000-48-Hx.C08 Page ...
Page 5
... Vsb < 0.7V (active, PS:On > 2.1V, < Vsb ± < 0.8V Vsb Vsb High Level I Max Low Level open drain - 2 mA < 0. open drain - < 0.7V > 2.1V (open, or Vsb < 0.7V (active, PS:On Vsb Vsb email: toronto@murata-ps.com 08 Apr 2010 CPS_D1U-W-2000-48-Hx.C08 Page ...
Page 6
... The DC output terminals are of terminal block style that will allow connection using crimp type right-angle lugs accepting up to AWG#2 wire, Panduit lug LCC2-14AWF-Q or equivalent is recommended. 2. Two M6 studs at 15.88 mm centre spacing are provided for connection to each pole. Hardware is provided for fastening the lugs/wires as well as terminal block covers 08 Apr 2010 CPS_D1U-W-2000-48-Hx.C08 Page REF 37,31 ±0,40 [ 1.469 ± ...
Page 7
... The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. 48V+ OUTPUT GND © 2010 Murata Power Solutions, Inc. email: toronto@murata-ps.com 08 Apr 2010 CPS_D1U-W-2000-48-Hx.C08 Page ...