POWER SUPPLY 60W 12V OUT

LPS53

Manufacturer Part NumberLPS53
DescriptionPOWER SUPPLY 60W 12V OUT
ManufacturerEmerson Network Power
SeriesLPS50
TypeOpen Frame
LPS53 datasheet
 

Specifications of LPS53

Voltage - Output12VNumber Of Outputs1
Power (watts)60WApplicationsCommercial
Power Supply TypeSwitching (Open Frame)Voltage - Input90 ~ 264VAC
Mounting TypeChassis Mount1st Output12 VDC @ 5A
Size / Dimension4" L x 2" W x 1.3" H (101.6mm x 50.8mm x 33mm)Power (watts) - Rated60W
Operating Temperature0°C ~ 50°CEfficiency85%
ApprovalsCB, CE, CSA, TUV, ULLine Regulation±2%
Load Regulation±2%Commercial/medicalCommercial
Output Power Rating60 WInput Voltage90 VAC to 264 VAC
Output Voltage (channel 1)12 VOutput Current (channel 1)5 A
Open Frame/enclosedOpen FrameOutput Current (max)5A
Output Voltage12VOutput Power (max)60W
Input Frequency47 to 440HzScreening LevelCommercial
Product Length (mm)101.6mmProduct Height (mm)33mm
Product Depth (mm)50.8mmOperating Temperature Min Deg. C0C
Operating Temperature Max Deg. C50CMounting StyleScrew
Pin Count8Lead Free Status / RoHS StatusLead free / RoHS Compliant
3rd Output-2nd Output-
4th Output-Other names454-1162
1
Page 1
2
Page 2
3
Page 3
Page 1/3

Download datasheet (678Kb)Embed
Next
LPS50 Series
60 Watts
Total Power:
55 - 60 Watts
Input Voltage:
90 - 264 VAC
127 - 300 VDC
# of Outputs:
Single
Special Features
• Universal input
• 2” x 4” footprint
• Less than 1U high
• Remote sense
• Overload and short circuit
protection
• Adjustable Output Voltage
• High efficiency
• High MTBF
• Built in EMI filter
(CISPR 22 Class B)
• LED power good indicator
• Input power < 74 watts
• Complies with EN61000-3-2
• UL Class I approved
• LPS52(-I) and LPS53 (-I)
extended temperature option:
-40 °C to +80 °C
• LPX50 enclosure kit available
Safety
UL 60950-1
UL
CSA CSA-C22.2 No. 60950-1
TUV EN60950-1
CB
Certificate and report
CE
LVD & EMC
Electrical Specifications
Input
Input range:
90 - 264 VAC (wide range)
127 - 300 VDC
Frequency:
47-440 Hz
Inrush current:
< 60A peak @ 230 VAC, cold start @ 25 °C
Input power:
< 74 Watts
Efficiency:
80% - 85% typical at full load
EMI/RFI:
FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B
conducted; VDE0878PT3 Class B conducted.
Safety ground leakage
< 0.5mA @ 50/60 Hz; 264 VAC input for class I; < 0.25mA @ 50/60Hz;
current:
264 VAC input for class II
Output
Maximum power:
60 W for convection (LPS52, 55 W)
Adjustment range:
± 20% minimum
Hold-up time:
10/ 2 0 ms 115/230 VAC Input line
Overload protection:
Short circuit protection on all outputs. Case overload protected @ 110-
160% of normal rating
Overvoltage protection: 30-50% above nominal output
Remote sense:
Compensates for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 1.08.09_144
LPS50 Series
1 of 3

LPS53 Summary of contents

  • Page 1

    ... Overload and short circuit protection • Adjustable Output Voltage • High efficiency • High MTBF • Built in EMI filter (CISPR 22 Class B) • LED power good indicator • Input power < 74 watts • Complies with EN61000-3-2 • UL Class I approved • LPS52(-I) and LPS53 (-I) extended temperature option: -40 °C to +80 °C • LPX50 enclosure kit available Safety UL 60950-1 • UL • CSA CSA-C22.2 No. 60950-1 • ...

  • Page 2

    Environmental Specifications Operating temperature: 0° °C ambient derate each output as 2.5% per degree from 50° °C. -20 °C start up Storage temperature: -40 °C to +85 °C Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity: Operating; non-condensing 10% to 95% RH Vibration: IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated: > 550,000 hours at full load and 25 °C ambient conditions Mechanical Drawing M1 + GRN/ YEL TP1 GND SK1 T3.15A 2.5A 250VAC 0.197” (5.0) Minimum Standoff Height VR1 Output Voltage Adjust Pot C4 ...

  • Page 3

    ... LPS55 24V 0A LPS58 48V 0A 1. Peak current lasting < 15 seconds with a maximum 10% duty cycle °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. LPS52(- extended temperature range model operating from -40 °C to +80 °C Pin Assignments LPS52 LPS53 Connector SK1-1 Line Line SK1-3 Neutral Neutral SK2 +12 V SK2 +12 V ...