NTQ163 Emerson Network Power, NTQ163 Datasheet

PS 165W 85-264VAC 3.3/5/12/12V

NTQ163

Manufacturer Part Number
NTQ163
Description
PS 165W 85-264VAC 3.3/5/12/12V
Manufacturer
Emerson Network Power
Series
NTQ160r
Datasheet

Specifications of NTQ163

Voltage - Output
3.3V, 5V, 12V, 12V
Number Of Outputs
4
Power (watts)
165W
Applications
Commercial
Power Supply Type
Linear, Regulated (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 15A
2nd Output
3.3 VDC @ 10A
3rd Output
12 VDC @ 2A
4th Output
12 VDC @ 2A
Size / Dimension
8.5" L x 4.25" W x 1.5" H (216mm x 108mm x 38.1mm)
Power (watts) - Rated
165W
Operating Temperature
0°C ~ 50°C
Efficiency
65%
Approvals
BABT, CB, CE, CSA, NEMKO, UL, VDE
Line Regulation
±2%, ±3%
Load Regulation
±2%, ±3%
Power Supply Output Type
Fixed & Variable
No. Of Outputs
4
Output Voltage
5V
Output Current
15A
Power Rating
165W
Input Voltage
85V AC To 264V AC
Length
216mm
Width
108mm
Output Power (max)
50W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
38.1mm
Product Depth (mm)
108mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
454-1239
NTQ163
116
50-165 Watts
NTQ160 Series
• Active power factor correction
• EN61000-3-2 compliance
• Remote sense on outputs
• Power fail and remote inhibit
• 5V Standby output
• DC Power good
• Single wire current sharing on
• Wide range adjustable on outputs 1 & 2
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
• Outputs 3 & 4 are floating
Operating temperature: 0° to 50°C ambient; derate
each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: Designed to meet
EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity: Operating; non-condensing
10% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances 0.7
G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ± .04% per °C
MTBF demonstrated: >1 million hours at full load and
25°C ambient conditions
one and two
outputs one and two
Americas: (760) 930-4600
Special Features
Environmental
Support: (888) 41-ASTEC or (407) 241-2752
Europe (UK) 44 (1384) 842-211
Total Power:
Input Voltage: 85-264 VAC
# of Outputs:
VDE
UL
CSA
NEMKO
BABT
CB
CE
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
Power factor
Safety ground leakage
current
Output
Maximum power
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Standby output
Logic Control
Power failure
Remote Inhibit
Remote sense
DC O
Electrical Specs
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
EN60950/EN41003
Certificate and report
Mark (LVD)
Safety
50-165 Watts
Quad
Asia (HK) 852-2437-9662
85-264 VAC
47-63 Hz
38 A max., cold start @ 25°C
65% typical at full load @ 115 VAC
input
FCC Class B conducted and radiated,
CISPR 22 Class B conducted and
radiated, EN55022 Class B conducted
and radiated, VDE 0878 PT3 Class B
conducted and radiated.
0.99 typical
<1 mA @ 50/60 Hz, 264 VAC input
50W convection, 165 W with 30 CFM
forced air
1.8V - 3.5V; 3.0V - 5.5V on outputs
one and two
20 ms @ 165 W load
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating. Latching type
recycle AC to reset.
Tracks outputs 1 & 2: 20% to 35%
above output setting
5V@ 2 A regulated ±5%
TTL logic signal goes high 100-500
msec after V1 output; it goes low at
least 4 msec before loss of regulation
Requires contact closure to inhibit
outputs
Compensates for 0.5 V lead drop
minimum, will operate without
remote sense connected. Reverse
connection protection.
TTL logic signal goes high after main
output is in regulation. It goes low
when there is a loss of regulation.
21310-3336-0021
(129066)
E186249
LR109492C
P00100493
650251, NC/00069
9661, 9662, 8788
rev 04.29.04

Related parts for NTQ163

NTQ163 Summary of contents

Page 1

Watts NTQ160 Series Special Features • Active power factor correction • EN61000-3-2 compliance • Remote sense on outputs one and two • Power fail and remote inhibit • 5V Standby output • DC Power good • Single wire current ...

Page 2

... Ordering Information Model Output Minimum Number Voltage Load NTQ162 +3.3 V(1.8 - 3.5V 5.5V NTQ163 + 5.5V +3.3 V (1.8 - 3.5V NTQ165 +3 5.5V +2.5 V (1.8 - 3.5V outputs are floating 1. Peak current lasting <30 seconds with a maximum 10% duty cycle 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. ...

Page 3

VR1 VR2 D27 HTSK-SEC3 D24 L15 IC8 IC7 R67 C84 C86 SK6 R87 C43 C46 C47 1 10 C72 THR3 C29 C41 C42 L9 THR2 SEC_DB R41 C37 C36 Z4 ...