PWR SUP TRIPLE +5V/+24V/-12V

ZPT4052412N

Manufacturer Part NumberZPT4052412N
DescriptionPWR SUP TRIPLE +5V/+24V/-12V
ManufacturerTDK Corporation
SeriesZP60
ZPT4052412N datasheets
 


Specifications of ZPT4052412N

Power Supply TypeSwitching (Open Frame)Voltage - Output5V, -12V, 24V
Number Of Outputs3Power (watts)40W
ApplicationsCommercialVoltage - Input90 ~ 264VAC
Mounting TypeChassis Mount1st Output5 VDC @ 3.2A
2nd Output24 VDC @ 1A3rd Output-12 VDC @ 300mA
Size / Dimension4" L x 2" W x 1.2" H (101.6mm x 50.8mm x 30.5mm)Power (watts) - Rated42.6W
Operating Temperature0°C ~ 70°CEfficiency75%
ApprovalsCE, CSA, EN, ULLine Regulation±1%, ±2%
Load Regulation±3%, ±5%, ±1%Power Supply Output TypeFixed
No. Of Outputs3Output Voltage5V
Output Current3.2APower Rating42.6W
Input Voltage90V AC To 264V AC / 120V DC To 370V DCLead Free Status / RoHS StatusLead free / RoHS Compliant
4th Output-Other names285-1664
ZPT40-52412N
1
Page 1
2
Page 2
Page 1/2

Download datasheet (425Kb)Embed
Next
ZPS40 , 40D/T & 60 Handbook
Input Parameters
RATED INPUT VOLTAGE RANGE
100 - 240V AC
INPUT FREQUENCY
47- 63Hz
RATED INPUT CURRENT
1.5A
INRUSH CURRENT (132/264VAC)
25/50 (COLD START)
Outputs
Output Parameters
Models
Model
Output Voltage (V)
Output Current (A)
ZPS40-3
3.3
6.0
ZPS60-3
3.3
8.0
ZPS40-5
5.0
6.0
ZPS60-5
5.0
8.0
ZPS40-9
9.0
4.45
ZPS60-9
9.0
6.67
ZPS40-12
12.0
3.34
ZPS60-12
12.0
5.0
ZPS40-15
15.0
2.67
ZPS60-15
15.0
4.0
ZPS40-24
24.0
1.67
ZPS60-24
24.0
2.5
ZPS40-28
28.0
1.43
ZPS60-28
28.0
2.14
ZPS40-30
30.0
1.33
ZPS60-30
30.0
2.0
ZPS40-36
36.0
1.11
ZPS60-36
36.0
1.67
ZPS40-48
48.0
0.834
ZPS60-48
48.0
1.25
ZPD40-512
+5.0
3.2
+12.0
2.0
ZPD40-524
+5.0
3.2
+24.0
1.0
ZPD40-5125N
+5.0
3.2
+12.0
2.0
-5.0
0.3
ZPT40-51212N
+5.0
3.2
+12.0
2.0
-12.0
0.3
ZPT40-51515N
+5
3.2
+15.0
1.5
-15.0
0.3
ZPT40-52412N
+5.0
3.2
+24.0
1.0
-12.0
0.3
ZPT40-5245N
+5.0
3.2
+24.0
1.0
-5.0
0.3
ZPT40-52412p
+5.0
3.2
+24.0
1.0
+12.0
0.3
ZPT40-3512N
+3.3
5.0
+5.0
2.0
-12.0
0.3
Output Limitations
Adjusting output voltage beyond the stated range may cause the overvoltage protection (OVP)
to operate, whereby the output will cycle on and off or latch off. To reset for normal operation
simply adjust the potentiometer to reduce the ouput voltage to within it’s range or cycle the
input off then on if the unit has latched off.
Important safety instructions
Servicing
These products are not customer serviceable. Repairs may only be carried out by Lambda UK or their
authorised agents. These products are not authorised for use as critical components in nuclear control
systems, life support systems or equipment for use in hazardous environments without the express
written approval of the Managing Director of Coutant Lambda Ltd.
Approval Limitations: Use in North America (AC units only)
When this product is used on 180VAC-250VAC mains with no neutral, connect the two live wires to
L(live) and N (neutral) terminals on the input connector. In this instance double pole fusing is required.
High Voltage Warning
Dangerous voltages present within the power supply. The proffesional installer must protect service
personnel from inadvertant contact with these dangerous voltages in the end equipment.
Safety Class of Protection
These products are designed for the following parameters : Material Group IIIa, Pollution Degree 2,
Overvoltage Category II, Class II, Indoor use as part of an overall equipment such that the product is
accessible to service engineers only.
Safety approvals
UL60950 and CSA 60950 EN60950,Class II and CE (LVD) mark.
Conducted and Radiated EMI
EN55022-B, FCC Class B
Immunity
EN61000-4-2,EN61000-4-3,EN6100-4-4,EN61000-4-6, EN61000-4-8
Environmental parameters
Operation
Temperature:
0 to +70
C (ZPS40-3,-5,-9 and ZPS60-3,-5,-9, >40
C -70
C derate at 2.5%/
0
0
0
0 to +70
C (ZPS40-12,-15,-24,-28,-30,-36,-40 and ZPD40,ZPD40 and ZPS60-12,-
0
15,-24,-28,-30,-36,-40 >40
C -70
C derate at 2.5%/
C)
0
0
0
Humidity:
10 to 95% RH, non-condensing
Storage and Transportation
Temperature: -20
0
C to +85
0
C
Humidity: 10% to 95% RH, non-condensing
Shock
<196.1 m/s
(20G)
2
Vibration
23.52 m/s
(10-55H
): constant sweep 1 min X , Y, Z for one hour)
2
Z
Cooling
Convection
Part Number 17164
Level of insulation
Dielectric Strength testing is carried out as follows:
Primary mains circuit to earth - 1.5kVAC.Primary mains circuits to secondary -3kVAC.
Outputs to each other and to earth are isolated to 500VDC.
Fuse Information
Fuse
Internal fuse (F1): T2.2AL, 250V.
Input Connector
Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal.
(Live)
ACL
(Neutral)
ACN
General installation instructions
The ZP family of component power supplies is designed for use within other equipment or
enclosures which restrict access to authorised competent personnel only. For safe installation and
operation of this product, carefully follow the instructions listed below.
i) These products are supplied open frame
ii) These products are Class II and must be installed in accordance with Class II requirements of
IE/EN/UL/CSAC60950.
iii) These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids
must not be used.
Output Connector
For ZPS40 and ZPS60 output connector mates with Molex Housing 09-50-3041 and Molex 2878
C )
0
series crimp terminal
For ZPS40D/T output connector mates with Molex Housing 09-50-3061 and Molex 2878 series
crimp terminal

ZPT4052412N Summary of contents

  • Page 1

    ZPS40 , 40D/T & 60 Handbook Input Parameters RATED INPUT VOLTAGE RANGE 100 - 240V AC INPUT FREQUENCY 47- 63Hz RATED INPUT CURRENT 1.5A INRUSH CURRENT (132/264VAC) 25/50 (COLD START) Outputs Output Parameters Models Model Output Voltage (V) Output Current ...

  • Page 2

    ZPS40 , 40D/T & 60 Handbook ZPS40 & 60 Outline Drawing ZPD/ZPT Outline Drawing Pin Connection (ZPD/ZPT) Pin Function Pin Function COM 5 COM 6 V3 Part Number 17164 CEL Part No. 17164 ...