LWD-30-1212 TDK Corporation, LWD-30-1212 Datasheet

PWR SUP 30W +12V +12V DUAL OUT

LWD-30-1212

Manufacturer Part Number
LWD-30-1212
Description
PWR SUP 30W +12V +12V DUAL OUT
Manufacturer
TDK Corporation
Series
LWr
Datasheets

Specifications of LWD-30-1212

Power Supply Type
Switching (Open Frame)
Voltage - Output
12V
Number Of Outputs
2
Power (watts)
30W
Applications
Commercial
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 1.2A
2nd Output
12 VDC @ 1.2A
Size / Dimension
5.75" L x 2.36" W x 0.98" H (146mm x 59.9mm x 25mm)
Power (watts) - Rated
30W
Operating Temperature
0°C ~ 60°C
Efficiency
70%
Approvals
CE, CSA, EN, UL, VDE
Line Regulation
1%
Load Regulation
2%
Power Supply Output Type
Fixed
No. Of Outputs
2
Output Voltage
12V
Output Current
1.2A
Power Rating
30W
Input Voltage
85V AC To 265V AC / 110V DC To 350V DC
Length
146mm
3rd Output
-
4th Output
-
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
285-1008
LWD30-1212
LWD301212
F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
Max Output Power (typ)
Efficiency (Typ)
AC Input Voltage range
DC Input Voltage range
Input Current Typ (100/200VAC)
Inrush Current (110/200VAC)
Output 1 Voltage Adjustment
Output Voltage Accuracy
Temperature Coefficient
Line Regulation
Load Regulation
Ripple & Noise
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ at 100VAC)
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted EMI
Weight (Typ)
Size (WxHxD)
Warranty
* LWT models only
Note: See Installation Manual for full details, test methods of parameters and application notes
Low Profile
Isolated 2nd and 3rd outputs
Wattbox design on LWT
MODEL
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
mm
ms
°C
W
%
A
A
V
g
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Input to Gnd, Input to Output 2kVAC (20mA)
5V:100mV , 12V & 15V: 150mV , 24V: 200mV
0.4/0.2
LWD15
17/34
180
15
64
LWD: 0°C to +60°C, derate as follows: 40°C: 100%, 50°C: 60%, 60°C: 40%
LWT: 0°C to +60°C, derate as follows: 40°C: 100%, 50°C: 80%, 60°C: 60%
Output 2 ±5%
FCC Class A
19.6m/s
-
>100M at 25C & 70%RH, Output to Ground 500VDC
5V: 5 to 5.25V, 12V: 12 to 12.6V, 15V: 15V to 15.75V
110 - 350VDC
Output 1 < 1%, Output 2 or 3, <2% at 0 - 60°C
0.72/0.36
2
LWD30
Main output only: 5.75 - 6.75V, manual reset
14/28
250
30
70
Benefit
Factory Automation
Test & Measurement
Automated Service
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
Assists System Integration
Enable series operation for higher voltages
Power trading between outputs
Not recommended for new design highlighted in green
Low Profile Dual & Triple Output
30 - 90% RH (Non condensing)
10 - 95% RH (Non condensing)
Please refer to outline drawings
26mm height
Outputs 2 and 3 isolated from output 1
Universal Input (85 - 265VAC)
85 - 265VAC (47 - 440Hz)
LW Series
-30 to +85°C
Convection
UL60950-1, CSA60950-1, EN60950-1, CE LVD
196.1m/s
One Year
0.4/0.22
LWT15H
Possible
>105%
14/28
Output 1: 100mV, Outputs 2 & 3: 150mV
220
Input to Gnd 2kVAC Input to Output 3kVAC (20mA)
1%
2%
17
72
20
10-55Hz(1 min) <19.6m/s
2
VDE Class B, FCC Class B
Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
Vending Machines, Elevators,
Video Gaming, Point of Sale Equipment
Output 2 & 3 ±5%
0.7/0.42
LWT30H
16/32
300
30
73
*
2
110 - 330VDC
(1 hr)
LWT50H
1.2/0/7
16/32
400
50
72
61

Related parts for LWD-30-1212

LWD-30-1212 Summary of contents

Page 1

... Output 1 < 1%, Output < 60°C 5V:100mV , 12V & 15V: 150mV , 24V: 200mV Main output only: 5.75 - 6.75V, manual reset LWD: 0°C to +60°C, derate as follows: 40°C: 100%, 50°C: 60%, 60°C: 40% LWT: 0°C to +60°C, derate as follows: 40°C: 100%, 50°C: 80%, 60°C: 60 90% RH (Non condensing) ...

Page 2

... LWD-30 (146.0) (12.1) 0.0 1.0 6.29 .35 LWD-50 (8.8) 0.5 3.0 (159.7) 1. DIMENSIONS ARE IN INCHES EXCEPT DIMENSIONS ARE IN MM. 0.0 0 TAPPED HOLES FOR CUSTOMER MTG. 0.0 0.4 SCREWS MUST NOT PROTRUDE INTO P.S. BY MORE THAN . MAX. 0.5 3 ...

Related keywords