GPC41-15 SL Power Electronics Manufacture of Condor/Ault Brands, GPC41-15 Datasheet

no-image

GPC41-15

Manufacturer Part Number
GPC41-15
Description
POWER SUPPLY SWITCHER 40W 15V
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GPC41r
Datasheet

Specifications of GPC41-15

Rohs Status
RoHS non-compliant
Voltage - Output
15V
Number Of Outputs
1
Power (watts)
41W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
15 VDC @ 2.7A
Size / Dimension
4" L x 2" W x 1.5" H (101.6mm x 50.8mm x 38.1mm)
Power (watts) - Rated
40W
Operating Temperature
0°C ~ 50°C
Efficiency
77%
Approvals
CE, CSA, EN, IEC, TUV, UL
Load Regulation
0.75%
3rd Output
-
2nd Output
-
4th Output
-
• Ultra small (2.00” x 4.00” x 1.50”)
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR
• Commercial Approved to UL1950, IEC950,
• Medical Approved to UL2601-1, IEC601-1 and
• RoHS Compliant (G suffix)
SPECIFICATIONS
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.3 A
Hold-Up Time
20 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Output Power
40 W continuous, 50 W peak. Peak ratings are for 60 s maximum duration,
10% duty cycle. During peak load condition, output regulation may exceed
total regulation limits.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit.
Recovery after fault is automatic. Factory set to begin power limiting at ap-
proximately 55 W. See output ratings chart for additional notes or conditions.
Overvoltage Protection.
See output ratings chart.
Efficiency
69-77% at full rated load, nominal input voltage, depending
on model.
Turn-on Time
Less than 1 s at 120 Vac, 25°C (inversely proportional to input voltage).
Input Protection
Requires external ac line fusing. A 2.5 A, 250 V rated fuse with I2t > 20 is
recommended.
Inrush Current
Inrush is limited by internal thermistor. Inrush at 240 Vac under cold start
conditions will not exceed 34 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Environmental
Designed for 0 to 50°C operation at full rated output
power; derate output current and total output power by
2.5% per °C above 50°C. See Environmental and
Packaging Specifications on next page.
GLOBAL PERFORMANCE SWITCHERS
Summary:
22 Class B (Commercial models) and CISPR 11
Class B (Medical models)
EN60950 and CSA22.2-234 L3
CSA22.2 No. 601
All specifications are typical at nominal input, full load at 25
marked to LVD
GPC41 Commercial/GPM41 Medical
O
C unless otherwise stated
41 WATT GLOBAL PERFORMANCE SWITCHERS
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise
probe directly across output terminals of the power supply.
Transient Response
Main output—500 μs typical response time for return to within 0.5% of final value
for a 50% load step change. ∆i/ ∆t<0.2 A/μs. Maximum voltage deviation is 3.5%.
Startup/ shutdown overshoot less than 3%.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions GPC41
Conducted Emissions GPM41
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Commercial Leakage Current
60 μA single fault; 60 Hz input.
Commercial Safety
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file
#E135803 commercial; CSA #LR46516 all models. All dc outputs are SELV under
normal and single fault conditions.
Medical Leakage Current
35 μA , 254 Vac 60 Hz input.
Medical Safety
Approved to UL2601, CSA22.2 No. 601 Level 3, IEC601.
UL file E116994; CSA #LR46516. The output(s) are intended for safety earthed Sig-
nal Output and Intermediate Circuits only. The output(s) are not acceptable for
patient connection without additional isolation. All dc outputs are SELV under
normal and single fault conditions.
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kH
EN61000-4-5, 1 kV diff., 2 kV com.
D C P o w e r S u p p l i e s

Related parts for GPC41-15

GPC41-15 Summary of contents

Page 1

... A/μs. Maximum voltage deviation is 3.5%. Startup/ shutdown overshoot less than 3%. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS Conducted Emissions GPC41 Conducted Emissions GPM41 Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Commercial Leakage Current 60 μ ...

Page 2

... Commercial Medical Model Model Output GPC41-5 GPM41-5 5.1 V GPC41-12 GPM41- GPC41-15 GPM41- GPC41-24 GPM41- GPC41- Note: Add “G” suffix to model number for RoHS compliant model. GPC41/GPM41 MECHANICAL SPECIFICATIONS 3 ENVIRONMENTAL SPECIFICATIONS Temperature (A) Humidity (A) Shock (B) Altitude Vibration (C) A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derate output current and total output power by 2.5% per ° ...

Related keywords