GNT30-12 SL Power Electronics Manufacture of Condor/Ault Brands, GNT30-12 Datasheet

no-image

GNT30-12

Manufacturer Part Number
GNT30-12
Description
POWER SUPPLY 12V 2.5A 50X80MM
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GNT30r
Datasheet

Specifications of GNT30-12

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
30W
Applications
Medical
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 2.5A
Size / Dimension
3.15" L x 1.95" W x 0.85" H (80mm x 50mm x 21.5mm)
Power (watts) - Rated
30W
Operating Temperature
0°C ~ 50°C
Efficiency
78%
Approvals
CSA, EN, UL
Line Regulation
2%
Load Regulation
2%
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Other names
271-2231
• 90-264 Vac input range
• Overvoltage and short circuit protection
• Approved to UL, CSA and EN Standards
• Small 50 mm x 80 mm footprint
• Class II input available (G2T30)
The GNT30 Series is a 30 W universal input AC/DC Power
supply in a very small footprint. With the medical approvals
the GNT30 is ideal for a variety of medical device applications
including, small single board computers, battery charging, and
running small motors, pumps, and solenoids. The series with full
approval to EN60601-1 Standard improves design-in time, and
reduces end system compliance costs.
All specifications are typical at nominal input, full load at 25
Low Power Medical Power Supplies 30 Watt AC/DC Universal Input Power Supply
OUPUT SPECIFICATIONS
Output Power
Total Regulation
Turn-on time
Transient response
Temperature Coef-
ficient
Overvoltage protection
Short Circuit protection
EMC INFORMATION
Conducted emissions
Radiated emissions
Line freq. harmonics
Voltage fluctuations
ESD Air
ESD Contact
Radiated immunity
Fast Transients (EFT)
Line surge immunity
Conducted immunity
Power freq. mag. field
Voltage dip immunity
150 l.f.m. airflow
0.25 A/ms 50% load
deviation
Power cycling
EN55011
EN55011
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Level B
Level A
Complies
Complies
8 kV contact
6 kV air
3 V/m
2 kV
1 kV diff /2 kV cm
3 V
3 A/m
5 cycles 40 % vnom 0.5 Watts.
rms
GNT30 MEDICAL SERIES
25 cycles 70 % vnom 20 W
30 Watts max.(See note 4
See table
1.5 s max.
3.5% max. dev. 1 ms recovery
to 1%
+/-0.03%/oC
125% +/-10%
Yes
O
C unless otherwise stated
ENVIRONMENTAL SPECIFICATIONS
Thermal Performance
Relative Humidity
Maximum Altitude
Vibration
Shock
INPUT SPECIFICATIONS
Input Voltage range
Input frequency
Input surge current
Ground Leakage current
Input current
Input fuse
SINGLE OUTPUT POWER SUPPLY
Universal input
132 Vac 60 Hz
120 Vac
230 Vac
F1,F2
operating ambient
(see chart)
non-operating
0 - 50
150 l.f.m (See note 4.)
50 -70
150 l.f.m
non-condensing
operating / non-operating
Operating
Non-operating
Operating
Non-operating
o
C
o
C ambient
SPECIFICATIONS
100-240 nom (90 - 264 max)
Vac
55 Hz +/- 10 Hz
32 A max.
100 mA (180 mA single fault)
0.6 A
0.37 A
2.5 A
0-50
-40 to +85
30 Watts
derate 2% /
0% - 95% RH
10,000 ft. / 40,000 ft. max.
1.5 g
5 g
20 g
40 g
rms
pk
pk
o
rms
C
20-2000 Hz
10 ms, half-sine
10 ms half-sine
20-2000 Hz
SUMMARY
o
C
o
C

Related parts for GNT30-12

GNT30-12 Summary of contents

Page 1

... Approved to UL, CSA and EN Standards • Small footprint • Class II input available (G2T30) The GNT30 Series universal input AC/DC Power supply in a very small footprint. With the medical approvals the GNT30 is ideal for a variety of medical device applications including, small single board computers, battery charging, and running small motors, pumps, and solenoids ...

Page 2

... GENERAL SPECIFICATIONS Hold-up time Efficiency isolation voltage Switching frequency Safety Approvals Maximum weight MODEL NUMBER 40 C Convection 50 o GNT30 4.0 A GNT30- 2.5 A GNT30- 2.0 A GNT30- 1.25 A GNT30- 1.07 A GNT30- 0.625 A NOTES 1. When the input voltage is less than 90 Vac the operating temperature range is 0 specs ...

Related keywords