Description
POWER SUPPLY LINEAR 30W 2V
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
International Linearr
Datasheets

Specifications of HC2-6-A+

Rohs Status
RoHS non-compliant
Voltage - Output
2V
Number Of Outputs
1
Power (watts)
30W
Applications
Commercial
Power Supply Type
Linear, Regulated (Open Frame)
Voltage - Input
100, 120, 240VAC
Mounting Type
Chassis Mount
1st Output
2 VDC @ 6A
Size / Dimension
5.63" L x 4.88" W x 2.5" H (143mm x 124mm x 63.5mm)
Power (watts) - Rated
30W
Operating Temperature
0°C ~ 50°C
Approvals
CE, CSA, EN, IEC, TUV, UL
Line Regulation
±0.05%
Load Regulation
±0.05%
3rd Output
-
2nd Output
-
4th Output
-
116
Commercial/Medical
FEATURES
• World-wide ac input ranges and safety standards
• Industry standard packages
• Commercial UL/CSA TUV/IEC approved—68 models to
• Burn-in with cycling; 3-year warranty
• Capacitors have highest CV & ripple current ratings
• Medical Approved to UL2601-1, IEC60601-1 and
SPECIFICATIONS:
Ac Input
100, 120 and 240 Vac: +10%, -13%; 215 Vac: +12%, -11
%; 47 to 63Hz. Tolerance for 230 Vac operation is +15%,
-10%. Derate output current 10% for 50 Hz operation.
Dc Output
See voltage rating chart. Adjustment range ±5% minimum
except HA series.
Line Regulation
±0.05% for a 10% change.
Load Regulation
± 0.05% for a 50% load change.
Output Ripple
3 mV +0.05% of output voltage, peak to peak maximum.
All “3-terminal regulator” outputs: 3 mV +0.2% peak to
peak maximum.
Transient Response
<50 microseconds for 50% load change.
Short Circuit Protection
Automatic current limit/foldback.
Overvoltage Protection
Built-in on all 5 V models, set at 6.2 V ±0.4 V. Other models
use optional overvoltage protection.
Commercial
UL1950; CSA C22.2 No. 950 L3; TUV certified to EN60950
CSA601.1
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
International + Linears
• Medical leakage current does not exceed 10 µA
• MTBF 200,000+ hours per Mil Handbk 217D (most units)
• All electrolytic caps rated at 105ºC
• Transformer insulation meets Class F (155ºC)
• Exceed FCC and CISPR22, Class B conducted emissions
Remote Sensing
Provided on all models; open sense lead protection built-in
(except HA series).
Stability
±0.05% for 24 hours after warmup.
Temperature Rating
0 to 50°C full rated, derated linearly to 40% at 70°C.
Temperature Coefficient
±0.01%/°C maximum.
Efficiency
5 V units: 45%; 12 and 15 V units: 55%; 20 and 24 V units: 60%.
Logic Inhibit and Current-Share
F & G models.
Medical Stock and Vibration
Per Mil-Std-810D, Method 514.3, Category 1, Procedure 1.
Per Mil-Std-810D, Method 516.3, Procedure III.
Storage
-40 to +85 °C.
Medical
marked to LVD

Related parts for HC2-6-A+

HC2-6-A+ Summary of contents

Page 1

Commercial/Medical Commercial FEATURES • World-wide ac input ranges and safety standards • Industry standard packages • Commercial UL/CSA TUV/IEC approved—68 models to UL1950; CSA C22.2 No. 950 L3; TUV certified to EN60950 • Burn-in with cycling; 3-year warranty • Capacitors ...

Page 2

Commercial/Medical ...

Page 3

Commercial/Medical ...

Page 4

International + Linears INTERNATIONAL + LINEARS MECHANICAL SPECIFICATIONS: A CASE (WT. 1 LB.) C CASE (WT. 4 LB.) Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com B CASE (WT. ...

Page 5

International + Linears INTERNATIONAL + LINEARS MECHANICAL SPECIFICATIONS: E CASE (WT. 10 LB.) F CASE (WT. F5: 14 LB.; F15, 24: 18 LB.) G CASE (WT. G5: 19 LB.) N CASE (WT. 7 LB.) Condor D.C. Power Supplies, Inc., 2311 ...

Page 6

International + Linears INTERNATIONAL + LINEARS MECHANICAL SPECIFICATIONS: AA CASE (WT. 2 LB.) CC CASE (WT. 7 LB.) Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com BB CASE (WT. ...

Page 7

International + Linears INTERNATIONAL + LINEARS MECHANICAL SPECIFICATIONS: CBB CASE (WT. 8 LBS.) DCC CASE (WT. 12 LBS.) Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com 122 DBB CASE ...

Related keywords