GLC75C SL Power Electronics Manufacture of Condor/Ault Brands, GLC75C Datasheet

no-image

GLC75C

Manufacturer Part Number
GLC75C
Description
POWER SUPPLY SWITCHER 75W QUAD
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GLC75r
Datasheet

Specifications of GLC75C

Rohs Status
RoHS non-compliant
Voltage - Output
5.1V, 12V, ±15V
Number Of Outputs
4
Power (watts)
75W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5.1 VDC @ 8A
2nd Output
12 VDC @ 2.5A
3rd Output
-15 VDC @ 1A
4th Output
15 VDC @ 2.5A
Size / Dimension
7" L x 4.25" W x 1.3" H (177.8mm x 108mm x 33mm)
Power (watts) - Rated
75W
Operating Temperature
0°C ~ 50°C
Efficiency
78%
Approvals
CE, CSA, EN, IEC, UL
Line Regulation
2%; 10%, -5%; 3%
Load Regulation
2%; 10%, -5%; 3%
GLOBAL PERFORMANCE SWITCHERS
GLC75 Commercial/GLM75 Medical
• Cost-effective multiple output power source
• Universal input 90-264 Vac
• 7.00”x 4.25”x 1.30” (Meets 1U height)
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR 22
• Complies with EN61000-3-2 Class A
• Also available in single output versions
• Commercial UL1950 3rd Edition, CSA22.2 No. 950 and
• Medical Approved to UL2601-1,
• RoHS Compliant Model Available (G suffix)
75 Watt Multiple Output Global Performance Switchers
SPECIFICATIONS
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load not to
exceed 2.3 A.
Output Power
Normal continuous output power is 75 W for unrestricted natural convection
cooling or 110 W with 26 cfm airflow. During peak load conditions output
regulation may exceed total regulation and noise limits.
Output Regulation
Measured by ±40% load change from 60% rated load with all other outputs
at 60% rated load and input voltage change from minimum to maximum rat-
ings. Output #1 requires 1A minimum load for proper regulation of other
outputs. Initial set tolerance is measured with all outputs at 60% of full rated
load. Output #2 requires 0.5A minimum load for proper regulation.
Overload Protection
Factory set to begin power limiting at approximately 120 W. Fully protected
against short circuit and output overload. Short circuit protection is cycling
type power limit.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with
noise probe directly across output terminals of the power supply.
Transient Response
Main Output: 500μSec typical response time for return to within 0.5% of final
value for a 50% load step change, ∆i/∆t<0.2A/μSec. Maximum voltage devia-
tion is 3.5%.
Overvoltage Protection
Built in on V1 with firing point set per table. OVP firing reduces output #1 and
#2 to less than 50% of nominal voltage in 50 ms.
Voltage Adjust
Factory set on standard unit; however, optional potentiometer (“-V” suffix)
adjusts voltage from 4.7 V to OVP point (6.2 V nominal) on the +5 V output.
Note: Output #1 must not be more than 1% below nominal to achieve full
output voltage range on Output #2. Output regulation limits in some models
may be exceeded when the main output is adjusted beyond +1% of nominal
voltage. High voltage settings may degrade the reliability of the unit due to
excessive power dissipation in some outputs.
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
EN60950-1 approvals
CSA22.2 No. 601.1-M90, and IEC/EN60601-1
All specifications are typical at nominal input, full load at 25
FEATURES:
O
C unless otherwise stated
Efficiency
68% -78% depending on model and load distribution.
Input Protection
Internal ac fuse provided on all units. Designed to blow only if a catastrophic
failure occurs in the unit.
Inrush Current
Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac
half-cycle under cold start conditions will not exceed 37 A.
Hold Up Time
20 ms minimum from loss of ac input power at full load, nominal line (120 Vac).
Temperature Coefficient
0.03%/°C typical on all outputs.
Power Fail
A standard TTL or CMOS compatible output goes low (< 0.5 V) 5ms before output
voltage drops more than 4% below nominal voltage upon loss of ac power. Signal
is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line
impedance and distortion. Other settings are available through adjustment of
built-in potentiometer (consult factory for assistance). Output will stay low for 20
ms minimum.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions GLC75
Conducted Emissions GLM75
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
Commercial Safety
All GLC models are approved to UL1950 3rd Edition, CSA22.2 No. 950, and
EN60950-1.
Medical Leakage Current
70 μA 264 V @ 50 Hz (normal conditions).
Medical Safety
GLM models are approved to UL2601-1, CSA22.2 No. 601.1M90, IEC/EN60601-1. CB
Report available.
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B: FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-3-2 Class A

Related parts for GLC75C

GLC75C Summary of contents

Page 1

GLOBAL PERFORMANCE SWITCHERS GLC75 Commercial/GLM75 Medical 75 Watt Multiple Output Global Performance Switchers FEATURES: • Cost-effective multiple output power source • Universal input 90-264 Vac • 7.00”x 4.25”x 1.30” (Meets 1U height) • 2-year warranty • Conducted EMI exceeds FCC ...

Page 2

... Commercial Medical RoHS Output Model Model Suffix* No. GLC75A GLM75A GLC75B GLM75B GLC75C GLM75C GLC75D GLM75D GLC75E GLM75E GLC75F GLM75F GLC75H GLM75H GLC75J GLM75J 4(C) GLC75P GLM75P Add “G” suffix to part number for RoHS compliant model. Contact factory for availability. A. Rating with unrestricted convection cooling. Total power not to exceed 75 W. ...

Related keywords