MPB125-2005G POWER ONE, MPB125-2005G Datasheet

PWR SUP 125W +5V/+12V OUT DUAL

MPB125-2005G

Manufacturer Part Number
MPB125-2005G
Description
PWR SUP 125W +5V/+12V OUT DUAL
Manufacturer
POWER ONE
Series
MPB125r
Type
Open Framer
Datasheet

Specifications of MPB125-2005G

Voltage - Output
5V, 12V
Number Of Outputs
2
Power (watts)
125W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 25A
2nd Output
12 VDC @ 500mA
Size / Dimension
5" L x 3" W x 1" H (127mm x 76.2mm x 25.4mm)
Power (watts) - Rated
125W
Operating Temperature
0°C ~ 50°C
Efficiency
80%
Approvals
CE, CSA, EN, IEC, TUV, UL
Line Regulation
±3%, ±5%
Load Regulation
±3%, ±5%
Output Current (max)
25/0.5A
Input Voltage
90 to 264V
Output Voltage
5/12V
Output Power (max)
125W
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Length (mm)
127mm
Product Height (mm)
26.9mm
Product Depth (mm)
76.2mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Mounting Style
Screw
Pin Count
19
Product
Switching
Commercial/medical
Commercial
Output Power Rating
125 W
Output Voltage (channel 1)
5 V
Output Current (channel 1)
25 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
0.5 A
Dimensions
5 in L x 3 in W x 1.25 in H
Output Type
AC/DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
179-2285
MPB125-2005-G
Description
Multiple Output Model Selection
MPB125-2003
MPB125-2005
MPB125-2012
MPB125-2015
MPB125-2024
MPB125-2048
MPB125-3000
MPB125-4250
MPB125-4350
NOTES:
OCT 24, 2005 revised to JUN 05, 2006
The MPB125 Series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC)
to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations.
Dual output units deliver a regulated main output plus a second 12V output for fans or other system functions. Multiple output models
provide tightly regulated DC power in a variety of configurations. The MPB125 is rated for convection as well as forced-air cooling.
Full output power is available with as few as 5 Cubic Feet per Minute (CFM) forced-air cooling with the exception of the MPB125-
2003 and -2003D which need only 10 CFM for full power. Optional remote on/off with standby power is also provided (see Options).
The MPB125 product line is approved to the latest international regulatory standards, and displays the CE Mark.
MODEL
1
2
3
4
5
6
7
8
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
For MPB125-2003 and -2003D, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1.
Maximum forced-air output power is 125 watts with 5 CFM airflow.
Maximum convection output power is 70 watts.
V2 is isolated from V1 and can be used as a negative or positive output.
12V output’s peak load maximum duration is 30 seconds. Average current must not exceed 5A.
Maximum power of 80 watts from V1 + V2 with 5 CFM forced-air cooling. See Application Note #M3 for details.
For loads less than 10 watts on V1 + V2 + V3, ripple and noise on the +5V output is Max. 2% peak-to-peak.
V1 current can be as high as 25A with a minimum airflow of 5 CFM.
2
3, 4
3, 4, 5
3, 4, 5
3, 4, 5
3, 4, 5
6
6
6
VOLTAGE
OUTPUT
(VOLTS)
+3.3V
+2.5V
+3.3V
+12V
+12V
+12V
+15V
+24V
+48V
+12V
+12V
+12V
-12V
-12V
-12V
+5V
+5V
+5V
+5V
12V
12V
12V
12V
MAXIMUM OUTPUT
CURRENT (AMPS),
5A/9Apk
5A/9Apk
5A/9Apk
130 LFM
10.5A
16.5A
MPB125 Multiple-Output AC-DC Series Data Sheet
12A
15A
10A
15A
0.5A
0.5A
0.5A
8.3A
0.5A
5.2A
0.5A
2.6A
0.5A
0.5A
0.5A
0.5A
30A
25A
7
7
7
7
Page 1 of 9
• RoHS lead free and lead-solder-exempt products are available
• High power density in an industry-standard 3" x 5" footprint
• Power Factor Correction (PFC) meets EN61000-3-2
• Main output remote sense
• Power Good signals
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
• MTBF In excess of 1M hours based upon field data
• Optional remote on/off with 5V standby
(See page 4 for ordering information)
Features
EN61000-4-2/-3/-4/-5
REGULATION
TOTAL
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±3%
±5%
±4%
±5%
±5%
±3%
±4%
±5%
±5%
±3%
±4%
±5%
±5%
%
RIPPLE & NOISE 1
% pk-pk
1.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
2%
1%
1%
1%
1%
8
8
8
www.power-one.com
-11.40V to -12.60V
-11.40V to -12.60V
-11.40V to -12.60V
REGULATION RANGE
11.80V to 12.60V
10.80V to 12.60V
11.64V to 12.36V
11.40V to 12.60V
14.54V to 15.45V
11.40V to 12.60V
23.28V to 24.72V
11.40V to 12.60V
46.56V to 49.44V
11.40V to 12.60V
11.40V to 12.60V
11.40V to 12.60V
11.40V to 12.60V
3.20V to 3.40V
4.85V to 5.15V
4.85V to 5.25V
2.42V to 2.58V
4.85V to 5.25V
3.20V to 3.40V
4.85V to 5.25V

Related parts for MPB125-2005G

MPB125-2005G Summary of contents

Page 1

... DC power in a variety of configurations. The MPB125 is rated for convection as well as forced-air cooling. Full output power is available with as few as 5 Cubic Feet per Minute (CFM) forced-air cooling with the exception of the MPB125- 2003 and -2003D which need only 10 CFM for full power. Optional remote on/off with standby power is also provided (see Options). ...

Page 2

... Total voltage compensation for cable losses on +Sense. Total voltage compensation for cable losses on -Sense. NOTES: 1) For MPB125-2003, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1. V1 current can be as high as 25A with a minimum airflow of 5 CFM. 2) -Sense must be connected to output common or load common for proper power supply operation. ...

Page 3

... There are some limits for parallel operation. See MPB125 Applications Note. N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation. An external diode is required on MPB125-2003 and MPB125-2005 models for redundancy on both V1 and V2, or when ordering, you can specify MPB125-2003D or -2005D which have an internal isolation diode. Isolation Diode Internal isolation diode is provided on V1 for all dual-output models except the MPB125-2003 and MPB125-2005 ...

Page 4

... NOTE: The addition of Option “R” increases the supply width from 3.0 to 3.8 inches. Consult factory for availability. 1 NOTES: For MPB125-2003 and -2003D, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1. V1 current can be as high as 25A with a minimum airflow of 5 CFM. Ordering Information: ...

Page 5

... POINT FOR REFERENCE ONLY 1.25" (31.75) PRINTED CIRCUIT BOARD Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. OCT 24, 2005 revised to JUN 05, 2006 MPB125 Multiple-Output AC-DC Series Data Sheet 5.00" (127.0) 4.55" (115.57) TOP VIEW SHOWN SIDE VIEW MPB125 -2012 ...

Page 6

... SAFETY GROUND CONNECTION POINT 1.25" (31.75) PRINTED CIRCUIT BOARD Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. OCT 24, 2005 revised to JUN 05, 2006 MPB125 Multiple-Output AC-DC Series Data Sheet 5.00" (127.0) 4.55" (115.57) TOP VIEW PIN #1 PIN #1 SCREWS SHOWN ...

Page 7

... CONNECTION POINT FOR REFERENCE ONLY 1.25" (31.75) PRINTED CIRCUIT BOARD Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. OCT 24, 2005 revised to JUN 05, 2006 MPB125 Multiple-Output AC-DC Series Data Sheet 5.00" (127.0) 4.55" (115.57) TOP VIEW J3 SIDE VIEW MPB125 -3000 ...

Page 8

... FOR REFERENCE ONLY 1.25" (31.75) PRINTED CIRCUIT BOARD Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. OCT 24, 2005 revised to JUN 05, 2006 MPB125 Multiple-Output AC-DC Series Data Sheet MPB125 Series “R” Option 5.00" (127.0) 4.55" (115.57) J6 PIN #1 TOP VIEW ...

Page 9

... TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. OCT 24, 2005 revised to JUN 05, 2006 MPB125 Multiple-Output AC-DC Series Data Sheet MPB125 Series “R” Option 5.00" (127.0) 4.55" ...

Related keywords