GPC55-12G SL Power Electronics Manufacture of Condor/Ault Brands, GPC55-12G Datasheet

no-image

GPC55-12G

Manufacturer Part Number
GPC55-12G
Description
POWER SUPPLY SWITCHER 55W 12V
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GPC55r
Datasheet

Specifications of GPC55-12G

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
55W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 4.7A
Size / Dimension
6.3" L x 3.94" W x 1.68" H (160mm x 100mm x 42.7mm)
Power (watts) - Rated
55W
Operating Temperature
0°C ~ 50°C
Efficiency
70%
Approvals
CE, CSA, IEC, TUV, UL
Line Regulation
2%
Load Regulation
2%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Conducted EMI complies with FCC Class B and CISPR 22
• Commercial Approved to UL1950, IEC950 and
• Medical Approved to UL2601-1, IEC601-1 and
• Complies with EN61000-3-2 Class A
• Single and multiple outputs
• RoHS Compliant Model Available (G suffix)
SPECIFICATIONS
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.7 A
Hold-Up Time
20 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Output Power
55 W continuous, 70 W peak. Peak ratings are for 60 s maximum duration,
10% duty cycle. During peak load condition, output regulation may exceed
total regulation limits.
Overload Protection
Fully protected against short circuit and output overload. Short circuit protec-
tion is cycling type power limit on outputs 1 & 2; foldback type on outputs 3
& 4. Recovery after fault is automatic. See output ratings chart for
additional notes or conditions. Factory set to begin power limiting at ap-
proximately 75 W.
Overvoltage Protection
Main outputs: 124% + 12%
Efficiency
70% at full rated load, nominal input voltage, depending on model and load
distribution.
Input Protection
Internal ac fuse provided. Designed to blow only if a catastrophic failure oc-
curs in the unit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start
conditions will not exceed 34 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Environmental
Designed for 0 to 50°C operation at full rated output power; derate output
current and total output power by 2.5% per °C above 50°C. See Environmen-
tal and Packaging Specifications on next page.
GLOBAL PERFORMANCE SWITCHERS
FEATURES:
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
CSA22.2-234 L3
CSA22.2 No. 601
All specifications are typical at nominal input, full load at 25
marked to LVD
GPC55 Commercial/GPM55 Medical
O
C unless otherwise stated
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise
probe directly across output terminals of the power supply.
Transient Response
Main output—500 μs typical response time for return to within 0.5% of final value
for a 50% load step change. ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%.
Startup/shutdown overshoot less than 3%.
Voltage Adjustment
Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions require-
ments:
EMI SPECIFICATIONS
Conducted Emissions GPC55 Static
Conducted Emissions GPM55
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
Commercial Leakage Current
0.7 mA 254 Vac @ 60 Hz input.
Commercial Safety
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file
#E135803 commercial; CSA #LR46516 all models. All dc outputs are SELV under
normal and single fault conditions.
Medical Leakage Current
35 μA 254 Vac @ 60 Hz input.
Medical Safety
Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL file E116994; CSA
#LR46516. The output(s) are intended for safety earthed Signal Output and
Intermediate Circuits only. The output(s) are not acceptable for patient connection
without additional isolation. All dc outputs are SELV under normal and single fault
conditions.
55 Watt Global Performance Switchers
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
EN61000-3-2 Class A
D C P o w e r S u p p l i e s

Related parts for GPC55-12G

GPC55-12G Summary of contents

Page 1

... Voltage Adjustment Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions require- ments: EMI SPECIFICATIONS Conducted Emissions GPC55 Static Conducted Emissions GPM55 Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Line Frequency Harmonics Commercial Leakage Current 0 ...

Page 2

... GPM55-28 GPC55-48 A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Add “G” suffix to model to indicate RoHS compliant moel. GPC55/GPM55 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING Temperature (A) See individual Specs -40 to +85° ...