MAP55-4001C POWER ONE, MAP55-4001C Datasheet

no-image

MAP55-4001C

Manufacturer Part Number
MAP55-4001C
Description
PWR SUP +5V+24V+12V-12V W/COV
Manufacturer
POWER ONE
Series
MAP55r
Datasheet

Specifications of MAP55-4001C

Voltage - Output
5V, ±12V, 24V
Number Of Outputs
4
Power (watts)
55W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
5 VDC @ 8A
2nd Output
24 VDC @ 2.5A
3rd Output
-12 VDC @ 1A
4th Output
12 VDC @ 1A
Size / Dimension
6" L x 3.27" W x 1.6" H (152.4mm x 83.1mm x 40.6mm)
Power (watts) - Rated
55W
Operating Temperature
0°C ~ 50°C
Efficiency
73%
Approvals
CE, CSA, EN, UL
Line Regulation
0.2%, 0.5%
Load Regulation
2%
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
Q3891951
JUL 14, 2006 revised to AUG 10, 2006
Single-Output Model Selection
NOTES:
Multiple-Output Model Selection
NOTES: 1) Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts.
Power-One's MAP55 Series of power supplies provides reliable, tightly-regulated DC power for commercial and
industrial systems. Wide-range AC input and full international safety, EMI, and ESD compliance ensure worldwide
acceptance. All units bear the CE Mark.
The MAP55 utilizes a thermally efficient U-channel chassis design, which allows full power operation in convection-
cooled applications. Other mechanical design innovations include metric and SAE mounting inserts on each mounting
surface to provide integration flexibility. Dual-mode connectors provide traditional terminal block connections or popular
single row Molex connector mating.
Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output
voltage requirements.
Description
MAP40-1005
MAP55-1012 12V/15V
MAP55-1024 24V/28V
MODEL
MAP55-4000
MAP55-4001
MAP55-4002
MAP55-4003
MAP55-4004
MODEL
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded.
1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
+12V
+24V
+12V
+12V
+12V
+15V
+24V
+15V
-12V
-12V
-12V
-15V
-15V
+5V
+5V
+5V
+5V
+5V
5V
-5V
-5V
11.4V to 15.75V
23.5V to 28.5V
4.7V to 5.50V
ADJUSTMENT
4.7V to 5.6V
4.7V to 5.6V
4.7V to 5.6V
4.7V to 5.6V
4.7V to 5.6V
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
55W Continuous Output Power
5.0/4.0A (Note 2)
2.5/2.2A (Note 2)
MAXIMUM OUTPUT
CURRENT
CURRENT
OUTPUT
8A
0.5A
0.5A
1.5A
0.5A
0.5A
0.5A
0.5A
2.5A
0.5A
0.5A
1.5A
0.5A
0.5A
6A
3A
6A
6A
3A
6A
6A
Page 1 of 3
5.8/4.7A (Note 2)
2.9/2.5A (Note 2)
CURRENT (NOTE 3)
CURRENT (NOTE 1)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
1A (Note 3)
PEAK OUTPUT
PEAK OUTPUT
2.5A
3.5A
2.5A
11A
8A
5A
8A
8A
5A
8A
8A
Features
MAP55 AC-DC Series Data Sheet
RoHS lead-solder-exempt compliant
Wide Range Input for 110/220 VAC Applications
Meets EN55022, Conducted Class B Limits
Compact Footprint: 6.00" x 3.27" x 1.60"
(152.4mm x 83.1mm x 40.6mm)
Greater than 225,000 Hours MTBF
Metric and SAE Mounting Inserts
REGULATION
REGULATION
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.2%
LINE
LINE
REGULATION
REGULATION
±1.5%
±1%
LOAD
LOAD
1%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
2%
RIPPLE & NOISE
RIPPLE & NOISE
%p-p (NOTE 2)
%p-p (NOTE 1)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
www.power-one.com
-11.6V to -12.4V
-11.6V to -12.4V
-11.6V to -12.4V
-14.4V to -15.6V
-14.5V to -15.5V
11.6V to 12.4V
23.0V to 24.9V
11.6V to 12.4V
11.6V to 12.4V
11.6V to 12.4V
14.6V to 15.4V
23.0V to 24.9V
14.5V to 15.5V
-4.8V to -5.2V
-4.8V to -5.2V
12.0V to 12.2V
23.8V to 24.2V
INITIAL SETTING
5.0V to 5.2V
5.0V to 5.2V
5.0V to 5.2V
5.0V to 5.2V
5.0V to 5.2V
INITIAL SETTING
5.0V to 5.2V
ACCURACY
ACCURACY

Related parts for MAP55-4001C

MAP55-4001C Summary of contents

Page 1

... NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Multiple-Output Model Selection ...

Page 2

... Turn-on Delay Time required for initial output voltage stabilization. Turn-on Rise Time Time required for output voltage to rise from 10% to 90% (Note 1). NOTES: 1) Nominal rise time for MAP55-1024 is 36 msec. Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Overload Protection Fully protected against output overload and short circuit ...

Page 3

... Add ‘C’ suffix to model number or order part number 412-59584-G separately. For convection cooled applications, derate output power to 45 watts on multiple output units, 50 watts on MAP55-1012 and MAP55-1024,and 40 watts on MAP40-1005. OVERALL SIZE: 6.00" x 3.27" x 1.60" (152.4mm x 83.1mm x 40.6mm) INPUT & OUTPUT CONNECTIONS: CHASSIS: 0.090" ...

Related keywords