GPC140-12G SL Power Electronics Manufacture of Condor/Ault Brands, GPC140-12G Datasheet

no-image

GPC140-12G

Manufacturer Part Number
GPC140-12G
Description
POWER SUPPLY SWITCHER 140W 12V
Manufacturer
SL Power Electronics Manufacture of Condor/Ault Brands
Series
GPC140r
Datasheet

Specifications of GPC140-12G

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
140W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 11.7A
Size / Dimension
8.5" L x 4.5" W x 2.12" H (215.9mm x 114.3mm x 53.9mm)
Power (watts) - Rated
140W
Operating Temperature
0°C ~ 50°C
Efficiency
70%
Approvals
CE, CSA, IEC, UL
Line Regulation
2%
Load Regulation
2%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
56
SPECIFICATIONS:
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated
output load: 3.7 A
Hold-Up Time
20ms minimum from loss of ac input at full load, nominal
line (115 Vac).
Output Power
140 W convection; 160 W with air flow. Peak ratings are
for 60 s maximum duration, 10% duty cycle.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit on
output 1. Recovery after fault is automatic.
Overvoltage Protection
Main outputs: 130% ± 15% typical.
Efficiency
70% at full rated load, nominal input voltage, depending
on model and load distribution.
Input Protection
Internal ac fuse provided. Designed to blow only if a
catastrophic failure occurs in the unit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 Vac,
averaged over the first ac half-cycle under cold start
conditions will not exceed 60 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Thermal Shutdown
Provided as a standard feature. Designed to protect unit
from prolonged overtemperature.
Environmental
Designed for 0 to 50°C operation at full rated output
power; derate output current and total output power by
2.5% per °C above 50°C. See Environmental and
Packaging Specifications on next page.
Power Fail
TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms
before output voltage drops more than 4% below
nominal voltage upon loss of ac power. The signal is
factory set to trip on 84 to 94 Vac brown-out depending
upon incoming line impedance and distortion. Other
settings are available to the user through adjustment of
built-in potentiometer.
GPC140
140 Watt Global Performance Switchers
Commercial/GPM140 Medical
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
mode. Measured with noise probe directly across output
terminals of the power supply.
Transient Response
Main output—500 µs typical response time for return to
within 0.5% of final value for a 50% load step change. i/
shutdown overshoot less than 3%.
Remote Sense
Provided as a standard feature.
Voltage Adjustment
Built-in potentiometer adjusts voltage ±5%.
Overload Protection
Factory set to begin power limiting at approximately 175 W.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions GPC140 EN55022 Class B; FCC Class B
Conducted Emissions GPM140 EN55011 Class B; FCC Class B
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Commercial Leakage Current
0.95 mA 254 Vac @ 60 Hz input.
Commercial Safety
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950
and EN60950. UL file #E135803 commercial; CSA
#LR46516 all models. The output(s) are intended for
safety earthed Signal Output and Intermediate Circuits
only. All dc outputs are SELV under normal and single
fault conditions.
Medical Leakage Current
60 µA 254 Vac @ 60 Hz input.
Medical Safety
Approved to UL2601, CSA22.2 No. 601 Level 3 and
IEC601. UL file E116994; CSA #LR46516. The output(s)
are intended for safety earthed Signal Output and
Intermediate Circuits only. The output(s) are not accept-
able for patient connection without additional isolation. All
dc outputs are SELV under normal and single fault
conditions.
FEATURES:
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR 22
• Single outputs
• Commercial Approved to UL1950, IEC950,
• Medical Approved to UL2601-1, IEC601-1 and
t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
EN60950 and CSA22.2-234 L3
CSA22.2 No. 601
marked to LVD
EN61000-4-5, 1 kV diff., 2 kV com.
COMPLIANCE LEVEL
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-3, 3 V/meter

Related parts for GPC140-12G

GPC140-12G Summary of contents

Page 1

... Factory set to begin power limiting at approximately 175 W. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions GPC140 EN55022 Class B; FCC Class B Conducted Emissions GPM140 EN55011 Class B; FCC Class B Static Discharge EN61000-4- contact air RF Field Susceptibility EN61000-4-3, 3 V/meter ...

Page 2

... GPC140 Commercial/GPM140 Medical Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Unrestricted natural convection cooling. C. Requires 26cfm moving air. GPC140/GPM140 MECHANICAL SPECIFICATIONS Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • ...