C1U-W-1200-48-TB2C Murata Power Solutions Inc, C1U-W-1200-48-TB2C Datasheet

POWER SUPPLY 1200W AC/DC 48V

C1U-W-1200-48-TB2C

Manufacturer Part Number
C1U-W-1200-48-TB2C
Description
POWER SUPPLY 1200W AC/DC 48V
Manufacturer
Murata Power Solutions Inc
Series
C1U-W-1200-48-Txr
Datasheet

Specifications of C1U-W-1200-48-TB2C

Number Of Outputs
1
Voltage - Output
48V
Power (watts)
1200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
48 VDC @ 24.6A
Size / Dimension
14.2" L x 5.5" W x 1.67" H (360.7mm x 139.7mm x 42.4mm)
Power (watts) - Rated
1200W
Operating Temperature
0°C ~ 50°C
Efficiency
90.6%
Approvals
c-CSA-us, EN, TUV, UL
Input Voltage
90 VAC to 264 VAC
Output Voltage (channel 1)
48 V
Output Current (channel 1)
2 A to 24.6 A
Dimensions
1.67 in L x 5.5 in W x 14.2 in H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1946
ht t p : / / w ww. m ur a t a - p s. c om
FEATURES









RoHS compliant
1200W (110/220Vac) Output power
48V Main output,
Dimensions: 1.67” x 5.5” x 14.2”
9.2 Watts per cubic inch density
N+1 redundancy capable
Active current sharing on main output
Over-voltage, over-current,
Internal cooling fans
3.3V, 5V or 12V standby output
over-temperature protection
www.murata-ps.com
www.murata-ps.com/rohs
For full details go to
 
PRODUCT OVERVIEW
The C1U-W-1200 is a 1200 Watt universal AC input, power-factor-corrected (PFC) front-end power
supply for general applications. The main output is 48V and standby output of either 5V, 3.3V, or 12V.
Packaged in U low profi le, it is designed to deliver reliable bulk power to servers, workstations, storage
systems or any 48V distributed power architecture systems requiring high power density. The highly
effi cient electrical and thermal design with internal cooling fans supports reliable operation conditions.
The C1U-W-1200 is designed to auto-recover from over-temperature faults.
1
the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial
cable with 50ohm scope termination is used.
Ripple and noise are measured with 0.1 uF of ceramic capacitance and 10 uF of tantalum capacitance on each of
SELECTION GUIDE
Part Number
C1U-W-1200-48-TA1C
C1U-W-1200-48-TC1C
C1U-W-1200-48-TA2C
C1U-W-1200-48-TC2C
C1U-W-1200-48-TB1C
C1U-W-1200-48-TB2C
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Maximum Input Current
Inrush Current
Power Factor
OUTPUT VOLTAGE CHARACTERISTICS
Output
Voltage
12Vsb
3.3Vsb
5Vsb
48V
Parameter
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise
Output Current
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise
Operating Range
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise
Operating Range
Load Capacitance
Voltage Set Point Accuracy
Line and Load Regulation
Ripple Voltage & Noise
Operating Range
Load Capacitance
1
1
1
1
Universal Line
Power Output
C1U-W-1200-48-Tx Series
1200W
1200W
1200W
1200W
1200W
1200W
Conditions
Ramp up
Ramp down
Output load >90%
Output load >50%
Conditions
20MHz Bandwidth
18 Jan 2011
Main Output
AC/DC Front End Power Supply
48V
48V
48V
48V
48V
48V
CPS_C1U-1200-48-Tx.A06 D1 Page 1 of 4
46.54
Min.
4.85
11.2
3.2
Min.
78.5
70.5
95%
75%
2
0
0
0
90
47
Standby
email: toronto@murata-ps.com
Output
3.3V
3.3V
12V
12V
5V
5V
Typ.
3.3
48
12
5
Typ.
55
10000
49.44
Max.
1530
1530
1530
24.6
5.15
12.4
480
120
3.4
4.5
1.7
50
50
Front to back
Front to back
Front to back
Max.
Back to front
Back to front
Back to front
86.5
4
264
63
78
15
90
Airfl ow
mV p-p
mV p-p
mV p-p
mV p-p
Units
Units
Arms
Vdc
Vdc
Vdc
Vdc
μF
μF
μF
μF
Vac
Vac
Apk
A
A
A
A
Hz

Related parts for C1U-W-1200-48-TB2C

C1U-W-1200-48-TB2C Summary of contents

Page 1

... Power Output Part Number Universal Line C1U-W-1200-48-TA1C 1200W C1U-W-1200-48-TC1C 1200W C1U-W-1200-48-TA2C 1200W C1U-W-1200-48-TC2C 1200W C1U-W-1200-48-TB1C 1200W C1U-W-1200-48-TB2C 1200W INPUT CHARACTERISTICS Parameter Conditions Input Voltage Operating Range Input Frequency Turn-on Input Voltage Ramp up Turn-off Input Voltage Ramp down Maximum Input Current Inrush Current Output load > ...

Page 2

... Latching Latching 2.5 AC/DC Front End Power Supply Typ. Max. Units 120 mV 90.6 1.5 150 ±600 ±165 ±250 ±10 20 Typ. Max. Units 70 ° Khrs Khrs 60 dB LpAm TUV approval (Bauart) EN 60950-1:2001 Typ. Max. Units 4. email: toronto@murata-ps.com 18 Jan 2011 CPS_C1U-1200-48-Tx.A06 D1 Page ° ...

Page 3

... AC/DC Front End Power Supply Typ. Max. Units Vrms Vrms Criteria Class A, 6dB margin Class A, 6dB margin 4kV contact discharge 8kV operational air discharge 15kV non-operational air discharge 1kV/2kV, Performance Criteria B 3 Vac, 80% AM, 1kHz, Performance Criteria A 3 A/m email: toronto@murata-ps.com 18 Jan 2011 CPS_C1U-1200-48-Tx.A06 D1 Page ...

Page 4

... Specifi cations are subject to change without notice. 18 Jan 2011 AC Input Terminal Block M4 Ground Stud Signal Connector Output Terminal M5 Studs Pin 1 Pin 2 Signal Connector © 2009 Murata Power Solutions, Inc. email: toronto@murata-ps.com CPS_C1U-1200-48-Tx.A06 D1 Page ...

Related keywords