PWR SUPPLY 35W 3.3/5/12VOUT TRPL

LPT61

Manufacturer Part NumberLPT61
DescriptionPWR SUPPLY 35W 3.3/5/12VOUT TRPL
ManufacturerEmerson Network Power
SeriesLPT60
LPT61 datasheet
 


Specifications of LPT61

Voltage - Output3.3V, 5V, 12VNumber Of Outputs3
Power (watts)60WApplicationsCommercial
Power Supply TypeSwitching (Open Frame)Voltage - Input85 ~ 264VAC
Mounting TypeChassis Mount1st Output3.3 VDC @ 5A
2nd Output5 VDC @ 2.5A3rd Output12 VDC @ 500mA
Size / Dimension5" L x 3" W x 1.69" H (127mm x 76.2mm x 42.9mm)Power (watts) - Rated60W
Operating Temperature0°C ~ 50°CEfficiency60%
ApprovalsCB, CE, CSA, NEMKO, UL, VDELine Regulation±2%, ±5%
Load Regulation±2%, ±5%Output Power Rating17 W
Input Voltage85 VAC to 264 VACOutput Voltage (channel 1)3.3 V
Output Current (channel 1)5 AOutput Voltage (channel 2)+ 5 V
Output Current (channel 2)2.5 AOutput Voltage (channel 3)+ 12 V
Output Current (channel 3)0.5 AMounting StyleChassis
Dimensions5 in L x 3 in W x 1.65 in HLead Free Status / RoHS StatusLead free / RoHS Compliant
4th Output-Other names454-1199
LPT61
1
Page 1
2
Page 2
3
Page 3
Page 1/3

Download datasheet (225Kb)Embed
Next
LPT60 Series
60 Watts
Total Power:
60 - 80 Watts
Input Voltage:
85 - 264 VAC
120 - 300VDC
# of Outputs:
Triple
Special Features
• Universal input
• 3" x 5" footprint
• Remote sense on main output
• Built-in EMI filter
• Low output ripple
• Adjustable main output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX60 enclosure kit available
Safety
VDE:
0805/EN60950 (IEC950)
11774-3336-1255
(LC #86665)
UL:
UL1950
E132002
CSA:
CSA 22.2-234 Level 3
LR53982C
NEMKO: EN 60950/EMKO-TUE
P95100123
(74-sec) 203
CB:
Certificate and report
1518, 1519, 1520
CE:
Mark (LVD)
Electrical Specifications
Input
Input ra nge:
85-264VAC
120-300VDC
Frequency:
47-440Hz
Inrush current:
<18A peak @ 115VAC;
<36A peak @ 230VAC, cold start @ 25°C
Input current:
1.5A max. (RMS) @ 115VAC
Efficiency:
70% typical at full load (60% for LPT61)
EMI:
FCC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted;
VDE 0878 PT3 Class B conducted
Safety ground
<0.5 mA @ 50/60 Hz, 264 VAC input
leakage current:
Output
Maximum Power:
60W for convection (LPT61, 35W);
80W with 30CFW forced air (LPT61, 55W)
Cross regulation:
±2% on output 1; ±5% on outputs 2, 3
Adjustment range:
-5, +10% minimum
Hold-up time:
20ms @ 40W load, 115 VAC nominal line
Overload protection:
Short circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
Overvoltage protection:
5.7 to 6.7 VDC on the main output
LPT41: 3.6 to 4.6VDC
Remote sense:
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 03.24.08
LPT60 Series
RoHS
1 of 3

LPT61 Summary of contents

  • Page 1

    ... Inrush current: <18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25°C Input current: 1.5A max. (RMS) @ 115VAC Efficiency: 70% typical at full load (60% for LPT61) EMI: FCC Class B conducted; CISPR 22 Class B conducted EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Safety ground <0 50/60 Hz, 264 VAC input ...

  • Page 2

    ... Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Ordering Information Maximum Load Model Output Minimum with Convnection Number Voltage Load cooling LPT61 +3.3V 0.7A 5A +5V 0A 2.5A +12V 0A 0.5A LPT62 +5V 0.7A 7A +12V ...

  • Page 3

    ... Mechanical Drawing 0.22" (5.6) GND M1 3.00" (76.2) 2.55" (64. 4.56" 0.22" (115.8) (5.6) 1.69" (42.9) 0.12" (3) Pin Assignments Connector LPT61 LPT62 LPT63 LPT64 LPT65 SK1-1 Neutral Neutral Neutral Neutral Neutral SK1-3 Line Line Line Line Line SK2-1 5V +12V +15V +12V +24V SK2 ...