LPT61 Emerson Network Power, LPT61 Datasheet

PWR SUPPLY 35W 3.3/5/12VOUT TRPL

LPT61

Manufacturer Part Number
LPT61
Description
PWR SUPPLY 35W 3.3/5/12VOUT TRPL
Manufacturer
Emerson Network Power
Series
LPT60r
Datasheet

Specifications of LPT61

Voltage - Output
3.3V, 5V, 12V
Number Of Outputs
3
Power (watts)
60W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 5A
2nd Output
5 VDC @ 2.5A
3rd Output
12 VDC @ 500mA
Size / Dimension
5" L x 3" W x 1.69" H (127mm x 76.2mm x 42.9mm)
Power (watts) - Rated
60W
Operating Temperature
0°C ~ 50°C
Efficiency
60%
Approvals
CB, CE, CSA, NEMKO, UL, VDE
Line Regulation
±2%, ±5%
Load Regulation
±2%, ±5%
Output Power Rating
17 W
Input Voltage
85 VAC to 264 VAC
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
5 A
Output Voltage (channel 2)
+ 5 V
Output Current (channel 2)
2.5 A
Output Voltage (channel 3)
+ 12 V
Output Current (channel 3)
0.5 A
Mounting Style
Chassis
Dimensions
5 in L x 3 in W x 1.65 in H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1199
LPT61

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPT61
Manufacturer:
ASTEC
Quantity:
1 000
Special Features
• Universal input
• 3" x 5" footprint
• Remote sense on main output
• Built-in EMI filter
• Low output ripple
• Adjustable main output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX60 enclosure kit available
Safety
VDE:
UL:
CSA:
NEMKO: EN 60950/EMKO-TUE
CB:
CE:
LPT60 Series
60 Watts
Total Power:
Input Voltage:
# of Outputs:
P95100123
0805/EN60950 (IEC950)
11774-3336-1255
(LC #86665)
UL1950
E132002
CSA 22.2-234 Level 3
LR53982C
(74-sec) 203
Certificate and report
1518, 1519, 1520
Mark (LVD)
60 - 80 Watts
85 - 264 VAC
120 - 300VDC
Triple
Electrical Specifications
Input
Input ra nge:
Frequency:
Inrush current:
Input current:
Efficiency:
EMI:
Safety ground
leakage current:
Output
Maximum Power:
Cross regulation:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection:
Remote sense:
85-264VAC
120-300VDC
47-440Hz
<18A peak @ 115VAC;
<36A peak @ 230VAC, cold start @ 25°C
1.5A max. (RMS) @ 115VAC
70% typical at full load (60% for LPT61)
FCC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted;
VDE 0878 PT3 Class B conducted
<0.5 mA @ 50/60 Hz, 264 VAC input
60W for convection (LPT61, 35W);
80W with 30CFW forced air (LPT61, 55W)
±2% on output 1; ±5% on outputs 2, 3
-5, +10% minimum
20ms @ 40W load, 115 VAC nominal line
Short circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
5.7 to 6.7 VDC on the main output
LPT41: 3.6 to 4.6VDC
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
RoHS
Embedded Power for
Business-Critical Continuity
Rev. 03.24.08
LPT60 Series
1 of 3

Related parts for LPT61

LPT61 Summary of contents

Page 1

... Inrush current: <18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25°C Input current: 1.5A max. (RMS) @ 115VAC Efficiency: 70% typical at full load (60% for LPT61) EMI: FCC Class B conducted; CISPR 22 Class B conducted EN55022 Class B conducted; VDE 0878 PT3 Class B conducted Safety ground <0 50/60 Hz, 264 VAC input ...

Page 2

... Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Ordering Information Maximum Load Model Output Minimum with Convnection Number Voltage Load cooling LPT61 +3.3V 0.7A 5A +5V 0A 2.5A +12V 0A 0.5A LPT62 +5V 0.7A 7A +12V ...

Page 3

... Mechanical Drawing 0.22" (5.6) GND M1 3.00" (76.2) 2.55" (64. 4.56" 0.22" (115.8) (5.6) 1.69" (42.9) 0.12" (3) Pin Assignments Connector LPT61 LPT62 LPT63 LPT64 LPT65 SK1-1 Neutral Neutral Neutral Neutral Neutral SK1-3 Line Line Line Line Line SK2-1 5V +12V +15V +12V +24V SK2 ...

Related keywords