LPT81 Emerson Network Power, LPT81 Datasheet

no-image

LPT81

Manufacturer Part Number
LPT81
Description
PWR SUPPLY TRPL 3.3/5/12V 55W
Manufacturer
Emerson Network Power
Series
LPT80r
Datasheet

Specifications of LPT81

Voltage - Output
3.3V, 5V, 12V
Number Of Outputs
3
Power (watts)
80W
Applications
Commercial
Power Supply Type
Switching (Open Frame)
Voltage - Input
85 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
3.3 VDC @ 8A
2nd Output
5 VDC @ 4A
3rd Output
12 VDC @ 700mA
Size / Dimension
5" L x 3" W x 1.29" H (127mm x 76.2mm x 32.8mm)
Power (watts) - Rated
80W
Operating Temperature
0°C ~ 50°C
Efficiency
75%
Approvals
AUSTEL, CB, CE, CSA, NEMKO, UL, VDE
Line Regulation
±2%, ±5%
Load Regulation
±2%, ±5%
Output Power Rating
26 W
Input Voltage
85 VAC to 264 VAC
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
8 A
Output Voltage (channel 2)
+ 5 V
Output Current (channel 2)
4 A
Output Voltage (channel 3)
+ 12 V
Output Current (channel 3)
0.7 A
Mounting Style
Chassis
Dimensions
5 in L x 3 in W x 1.29 in H
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1166
LPT80 Series
80 Watts
Total Power:
Input Voltage:
# of Outputs:
Special Features
• Power Factor Correction
• EN61000-3-2 compliant
• Universal input
• 3” x 5” footprint
• Remote sense on outputs 1
(& 2 for LPT81)
• Power fail and remote inhibit
• Wide range adjustable on
outputs 1 (& 2 for LPT81)
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
Safety
VDE
UL
CSA
NEMKO 60950
AUSTEL
CB
CE
60950
60950
60950
60950
Certificate & report
Mark LVD
55 - 85 Watts
85 - 264 Vac
120 - 370 Vdc
Triple
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Input current:
Efficiency:
EMI filter:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: Tracks outputs 1( & 2 for LPT81): 20% to 35% above output setting
85 - 264 Vac; 120 - 300 Vdc
47 - 440 Hz
< 18 A peak @ 115 Vac;
< 36 A peak @ 230 Vac,
cold start @ 25 °C
1.5 A max. (RMS) @ 115 Vac
75% typical at full load
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
< 1 mA @ 50/60 Hz, 264 Vac input
60 W for convection (LPT81, 55 W);
85 W with 30 CFM forced air
3.3 V - 5.5 V on outputs one
(and two 1.8 V - 3.5 V for LPT81)
20 ms @ 85 W load, 115 Vac nominal line
Short circuit protection on all outputs.
Case overload protected @ 145% above peak rating
Embedded Power for
Business-Critical Continuity
Rev. 2.20.09_161
LPT80 Series
1 of 3

Related parts for LPT81

LPT81 Summary of contents

Page 1

... Safety ground leakage current: Output Maximum power for convection (LPT81 with 30 CFM forced air Adjustment range outputs one (and two 1 3.5 V for LPT81) Hold-up time load, 115 Vac nominal line Overload protection: Short circuit protection on all outputs. Case overload protected @ 145% above peak rating Overvoltage protection: Tracks outputs 1( & 2 for LPT81): 20% to 35% above output setting Embedded Power for Business-Critical Continuity Rev. 2.20.09_161 LPT80 Series ...

Page 2

... Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 500 Hz, operational MTBF demonstrated: > 550,000 hours at full load and 25 °C ambient conditions Ordering Information Model Minimum Output Voltage Number Load LPT81 +3.3 V (1.8 - 3 (3.3 - 5.5 V) 0 LPT82 +5 V (3.3 - 5.5 V) 0.7 A +12 V 0.3 A -12 V ...

Page 3

... Mechanical Drawing 0.23 (5.8) 3.00 (76.2) 2.55" (64.8) 0.22 (5.6) Pin Assignments Connector LPT81 LPT82/83 SK1 Pin1 Neutral Neutral Pin3 Line Line SK2 Pin1 V1 (3.3V Pin2 V1 (3.3V Pin3 Common Common Pin4 Common Common Pin5 Common Common Pin6 V2 (5V) V2 (12/15V) Pin7 V2 (5V) V2 (12/15V) Pin8 ...

Related keywords