MTC600-ACNR16S1J Emerson Network Power, MTC600-ACNR16S1J Datasheet - Page 6

MODULE POWER 600W AC 16CH

MTC600-ACNR16S1J

Manufacturer Part Number
MTC600-ACNR16S1J
Description
MODULE POWER 600W AC 16CH
Manufacturer
Emerson Network Power
Series
MTC600r
Datasheet

Specifications of MTC600-ACNR16S1J

Voltage - Output
3.63V, 12.95V
Number Of Outputs
2
Power (watts)
600W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Rack Mount
1st Output
12.95 VDC @ 7.6A
2nd Output
3.63 VDC @ 250mA
Size / Dimension
7.37" L x 2.34" W x 2.89" H (187.2mm x 59.44mm x 73.4mm)
Power (watts) - Rated
600W
Operating Temperature
-5°C ~ 45°C
Approvals
CSA, CUL, UL, VDE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1308

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MTC600-ACNR16S1J
Quantity:
3
Electrical Specifications (continued)
Output - All Models (continued)
General
Turn-on Time
Early Power
Normal Power
Autonomous Operation
Diagnostic Mode
Redundancy
Hot-Swap Operation
(controlled)
Hot-Swap Operation
(uncontrolled)
Power Module Failover
Fault Isolation
Note 7: All specifi cations in the redundancy sub-section assume the system is populated with Power Modules with the same
manufacturer's model numbers or otherwise compatible Power Modules. At the time of print, PICMG does not have a formal
methodology for verifying compatibility.
7
[GA2,GA1,GA0] = 101, or
[GA2,GA1,GA0] = 110
4 seconds maximum
LED1 displays yellow
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Supported
PM supports Normal Power requirements refer-
within specified voltage magnitude and timing
autonomous outputs to reach regulation band
enced in MicroTCA.0 Rev 1.0 Section 4.4.11.1
enced in MicroTCA.0 Rev 1.0 Section 4.4.11.2
PM supports Autonomous Operation require-
In Diagnostic Mode PM disables the IPMI con-
is capable of accepting the load of a failed PM
PM supports Early Power requirements refer-
When configured as a redundant PM, the PM
trols and slots are powered up based only on
Removal or addition of a PM will not cause a
Removal or addition of a PM will not cause a
ments referenced in MicroTCA.0 Rev 1.0
After power-on of the PM, the time for
Embedded Power for
Business-Critical Continuity
fault or out-of-regulation condition
fault or out-of-regulation condition
A fault in one PM will not cause the
shutdown of another PM
Section 4.4.11.3
PSI# signals
parameters
MTC600 Series
Rev. 05.26.08
6 of 19