HS7144ECH61H Renesas Electronics America, HS7144ECH61H Datasheet

no-image

HS7144ECH61H

Manufacturer Part Number
HS7144ECH61H
Description
DEV EMULATOR PCB ADAPTOR FP-112B
Manufacturer
Renesas Electronics America
Datasheets

Specifications of HS7144ECH61H

Accessory Type
User Interface Cable
For Use With/related Products
SH7144
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
To our customers,
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Renesas Electronics website:
Old Company Name in Catalogs and Other Documents
http://www.renesas.com
April 1
Renesas Electronics Corporation
st
, 2010

Related parts for HS7144ECH61H

HS7144ECH61H Summary of contents

Page 1

To our customers, Old Company Name in Catalogs and Other Documents st On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the ...

Page 2

All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm ...

Page 3

... SH7144 Group FP-112B User System Interface Board HS7144ECH61H User’s Manual Renesas Microcomputer Development Environment System SuperH™ Family/SH7144 Series Rev.4.0 2004.01 ...

Page 4

Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may ...

Page 5

... Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. User system interface cable (HS7144ECH61H) The user system or a host computer is not included in this definition. Purpose of the User System Interface Cable: This user system interface cable is for connecting the evaluation chip board and user system ...

Page 6

LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in ...

Page 7

State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and ...

Page 8

READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL ...

Page 9

Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST not ...

Page 10

... The HS7144ECH61H is a user system interface board that connects a user system for the SH7144 FP-112B package to the SH7046 E6000H emulator (HS7046EPH60H). Preface i ...

Page 11

Section 1 Configuration.....................................................................................1 Section 2 Environmental Conditions.................................................................3 2.1 Setting Operating Voltage and Operating Frequency ....................................................... 3 Section 3 Product Specifications .......................................................................4 Drop in Vcc Level Detection Function: ............................................................................ 4 Section 4 User Interface Specifications.............................................................5 4.1 User System Interface Circuit ........................................................................................... ...

Page 12

Figure 1 and table 1 show the configuration and components of the user system interface board for the FP-112B package. Please make sure you have all of these components when unpacking. Screws (M2 mm) with flat washers Socket ...

Page 13

... With two spacers (2.6MP For the FP-112B package (to be mounted on the user system) 1 For the FP-112B package (for installing MCU) 4 For fastening board (with four flat washers) 4 For installing an FP-112B-packaged MCU (with four flat washers) 1 User’s manual for HS7144ECH61H (this manual) ...

Page 14

Section 2 Environmental Conditions Maintain the conditions in table 2 when using the emulator. Table 2 Environmental Conditions Item Specifications Temperature Operating: +10 to +35°C Storage: -10 to +35°C Humidity Operating 80% RH, no condensation Storage ...

Page 15

Section 3 Product Specifications The specifications of this product are shown in table 3. Table 3 Product Specifications Item Specifications Target processor SH7144F Package FP-112B Function Level limitation: This function keeps the output signal from 3-V emulator system equal to ...

Page 16

Section 4 User Interface Specifications The user system interface board incorporates a level conversion circuit supporting a low-voltage circuit. Accordingly, when connecting the user system to the emulator, pay attention to the signal delays and the number of FANINs and ...

Page 17

AVcc and AN7 to AN0 5Vcc Emulator Vss Figure 5 User System Interface Circuit for AVcc and AN7 to AN0 6 QS3384 AN7 to AN0 User system AVss ...

Page 18

Section 5 Connection Procedures 5.1 Connecting User System Interface Board to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE BOARD is connected to or removed from any part. Before connecting, make ...

Page 19

Installing Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-112B package on the user system with pin 1 on the user system interface board, and insert the user ...

Page 20

User system Figure 6 Connecting User System Interface Board to User System Screws (M2 mm) with flat washers Board Pin 1 IC socket (IC149-112C15333-0B YAMAICHI ELECTRONICS Co., Ltd.) manufactured by 9 ...

Page 21

Connecting User System Interface Board to EV-Chip Board Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. ...

Page 22

Spacer User system Figure 7 Connecting User System Interface Board to EV-Chip Board EV-chip board Connector No. EV-Chip Board Connector No. Board Board Connector No. UCN1 UCN1 UCN2 UCN2 11 ...

Page 23

Recommended Dimensions for User System Mount Pad (Footprint) Figure 8 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-112B package (IC149-112C15333-0B: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note ...

Page 24

Dimensions for EV-Chip Board and User System Interface Board The dimensions for the EV-chip board and the user system interface board are shown in figure 9. Figure 9 Dimensions for EV-Chip Board and User System Interface Board 140.0 EV-chip ...

Page 25

Resulting Dimensions after Connecting User System Interface Board The resulting dimensions, after connecting the user system interface board to the user system, are shown in figure 10. Spacer ( 6.0) Figure 10 Resulting Dimensions after Connecting User System Interface ...

Page 26

Section 6 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.098 N•m or less. If ...

Page 27

Screws (M2 mm) with flat washers User system Figure 11 Installing MCU to User System 16 Socket cover MCU (SH7144) Pin 1 IC socket (IC149-112C15333-0B manufactured by YAMAICHI ELECTRONICS Co., Ltd.) ...

Page 28

Section 7 Verifying Operation 1. Turn on the emulator according to the procedures described in the SH7046 E6000H Emulator User's Manual (HS7046EPH60HE). 2. Verify the user system interface cable connections by checking the pin states with the extended monitor and ...

Page 29

To use the crystal oscillator mounted on the EV-chip board Install a crystal oscillator into the crystal oscillator terminals on the EV-chip board. Crystal oscillator terminals Figure 13 Installing the Clock Oscillator 18 Enlarged view Crystal oscillator X1 X2 Evaluation ...

Page 30

Before connecting any parts or cables, make sure that pin 1 on the both sides are correctly aligned not apply excessive force to the user system interface board while it is connected to the user system. 3. ...

Page 31

... SH7144 Group FP-112B User System Interface Board HS7144ECH61H User's Manual Publication Date: Rev.4.00, January 29, 2004 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. 2004 Renesas Technology Corp. All rights reserved. Printed in Japan. ...

Page 32

... User System Interface Board HS7144ECH61H User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan SH7144 Group FP-112B REJ10B0038-0400H ...