HS2258ECH61H Renesas Electronics America, HS2258ECH61H Datasheet

no-image

HS2258ECH61H

Manufacturer Part Number
HS2258ECH61H
Description
DEV EMULATOR PCB ADAPTOR TFP-100
Manufacturer
Renesas Electronics America
Datasheet

Specifications of HS2258ECH61H

Accessory Type
User Interface Cable
For Use With/related Products
H8S/2258
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
To our customers,
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Renesas Electronics website:
Old Company Name in Catalogs and Other Documents
http://www.renesas.com
April 1
Renesas Electronics Corporation
st
, 2010

Related parts for HS2258ECH61H

HS2258ECH61H Summary of contents

Page 1

To our customers, Old Company Name in Catalogs and Other Documents st On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the ...

Page 2

All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm ...

Page 3

...

Page 4

... H8S/2258 Series QFP-100B/TQFP-100B User System Interface Cable (HS2258ECH61H) for E6000 Emulator User’s Manual Rev.0.1 2000.09 ...

Page 5

...

Page 6

... Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Hitachi, Ltd. excluding all subsidiary products. User system interface cable (HS2258ECH61H) The user system or a host computer is not included in this definition. Purpose of the User System Interface Cable: This user system interface cable is for connecting the emulator station and user system ...

Page 7

LIMITED WARRANTY Hitachi warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Hitachi will repair or replace any user system interface cables determined to be defective in ...

Page 8

State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and ...

Page 9

READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL ...

Page 10

When using this document, keep the following in mind: 1. This document may, wholly or partially, be subject to change without notice. 2. All rights are reserved: No one is permitted to reproduce or duplicate, in any form, the whole ...

Page 11

...

Page 12

... Thank you for purchasing this user system interface cable (HS2258ECH61H) for the Hitachi’s original microcomputer H8S/2258 series. The HS2258ECH61H is a user system interface cable that connects an H8S/2633 series E6000 emulator (HS2633EPI61H; hereinafter referred to as the emulator) to the IC socket for a QFP-100B or TQFP-100B package (package code: FP-100B or TFP-100B) for the H8S/2258 series MCU on the user system ...

Page 13

Section 1 Configuration ....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station ..........................................3 2.2 Connecting User System Interface Cable to User System .................................................4 2.2.1 Installing IC Socket ..............................................................................................4 2.2.2 Soldering IC Socket..............................................................................................5 2.2.3 Inserting ...

Page 14

... Section 1 Configuration Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B or TFP-100B package IC socket on the user system. Figure 1 shows the configuration of the HS2258ECH61H user system interface cable for the FP-100B or TFP-100B package. To emulator station Screws (M2 mm) with flat washers Socket cover ...

Page 15

... Table 1 lists the HS2258ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2258ECH61H Components No. Component 1 Cable body 2 Cable head 3 IC socket 4 Socket cover 5 Screws (M2 mm) 6 Screws (M2 mm) 7 Documentation 2 Quantity Remarks 1 Includes two flat cables 1 Includes a shaped board ...

Page 16

Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make ...

Page 17

Figure 2 Connecting User System Interface Cable to Emulator Station 2.2 Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed ...

Page 18

Soldering IC Socket After fastening, solder the IC socket for an FP-100B or TFP-100B package to the user system. Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. ...

Page 19

Fasten the user system interface cable head to the IC socket for an FP-100B or TFP-100B package on the user system with the four screws (M2.6 should be tightened a little at a time, alternating between screws on opposing corners. ...

Page 20

Fastening Cable Body 1. Open the cable holder at the cable head. 2. Placing the cable body so it fits inside the cable holder, connect the cable body to the cable head. 3. Close the cable holder to prevent ...

Page 21

Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100B or TFP-100B package (IC149-100-054-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). ...

Page 22

Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 29.0 17.3 45.7 60.0 63.5 80.0 99.0 4.0 Unit: ...

Page 23

Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. IC socket User system (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) ...

Page 24

Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.294 N•m or less. If ...

Page 25

User system Figure 8 Installing MCU to User System 12 Screws (M2 mm) with flat washers Socket cover MCU Pin 1 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) ...

Page 26

Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2633 series, turn on the emulator according to the procedures described in the H8S/2633 Series E6000 Emulator User's Manual (HS2633EPI61HE). 2. Verify the user system interface cable connections ...

Page 27

Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount ...

Related keywords