HS36014ECH64H Renesas Electronics America, HS36014ECH64H Datasheet
HS36014ECH64H
Specifications of HS36014ECH64H
Related parts for HS36014ECH64H
HS36014ECH64H Summary of contents
Page 1
To our customers, Old Company Name in Catalogs and Other Documents st On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the ...
Page 2
All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm ...
Page 3
To all our customers Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp. The semiconductor operations of Mitsubishi Electric and Hitachi were transferred to Renesas Technology Corporation on April ...
Page 4
Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may ...
Page 5
... H8/36014series FP-48B User System Interface Cable (HS36014ECH64H) for E6000 Emulator User’s Manual Rev.1.0 2002.07 ...
Page 6
Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Hitachi bears no responsibility for problems that may arise with ...
Page 7
... Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Hitachi, Ltd. excluding all subsidiary products. User system interface cable (HS36014ECH64H) The user system or a host computer is not included in this definition. Purpose of the User System Interface Cable: This user system interface cable is for connecting the emulator station and user system ...
Page 8
LIMITED WARRANTY Hitachi warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Hitachi will repair or replace any user system interface cables determined to be defective in ...
Page 9
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and ...
Page 10
READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL ...
Page 11
Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST not ...
Page 12
... Thank you for purchasing this user system interface cable (HS36014ECH64H) for the Hitachi’s original microcomputer H8/36014series. The HS36014ECH64H is a user system interface cable that connects an H8/36014series E6000 emulator (HS3664EPI61H; hereinafter referred to as the emulator) to the IC socket for a FP-48B package for the H8/36014series MCU on the user system. ...
Page 13
Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station .......................................... 3 2.2 Connecting User System Interface Cable to User System................................................. 5 2.2.1 Installing IC Socket.............................................................................................. 6 2.2.2 Soldering IC Socket ............................................................................................. 7 ...
Page 14
... Section 1 Configuration Use an NQPACK048SD socket (manufactured by Tokyo Eletech Corporation) for the FP-48B package IC socket on the user system. Figure 1 shows the configuration of the HS36014ECH64H user system interface cable for the FP-48B package. Figure 1 HS36014ECH64H User System Interface Cable CAUTION 1 ...
Page 15
... Table 1 lists the HS36014ECH64H components. Please make sure you have all of these components when unpacking. Table 1 HS36014ECH64H Components No. Component 1 Cable body 2 Cable head 3 IC socket 4 Socket cover 5 Screws ( mm) 6 Screws ( mm) 7 CTS screws ( mm) Guide pins ( 1 mm Screwdriver 10 Documentation 2 Quantity Remarks 1 Coaxial cable ...
Page 16
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will ...
Page 17
Figure 2 Connecting User System Interface Cable to Emulator Station 4 ...
Page 18
Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 ...
Page 19
Installing IC Socket After checking the location of pin 1 on the IC socket fasten it to the user system before soldering. After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the ...
Page 20
Soldering IC Socket After fastening, solder the IC socket for a FP-48B package to the user system. Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly ...
Page 21
Fastening Cable Head 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw ...
Page 22
Fasten the user system interface cable head to the IC socket for a FP-48B package on the user system with the four screws (M2 time, alternating between screws on opposing corners. Take special care, such as manually securing the IC ...
Page 23
Fastening Cable Body Connect the cable body to the cable head. 10 Figure 5 Fastening Cable Body ...
Page 24
Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for a FP-48B package (NQPACK048SD: manufactured by Tokyo Eletech Coporation). Note that the ...
Page 25
Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Figure 7 Dimensions for User System Interface Cable Head 12 ± ...
Page 26
Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Figure 8 Resulting Dimensions after Connecting User System Interface Cable ± ...
Page 27
Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.098 N•m or less. If the applied torque ...
Page 28
Figure 9 Installing MCU to User System 15 ...
Page 29
Section 4 Verifying Operation 1. When using the H8/36014series E6000 emulator (HS3664EPI61H), turn on the emulator according to the procedures described in the H8/300H Series E6000 Emulator User's Manual (HS300HEPI61HE). 2. Verify the user system interface cable connections by accessing ...
Page 30
Figure 10 shows the system clock oscillator on the user system interface cable Figure 10 System Clock Oscillator 17 ...
Page 31
Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount ...