HS3802ECH62H Renesas Electronics America, HS3802ECH62H Datasheet

no-image

HS3802ECH62H

Manufacturer Part Number
HS3802ECH62H
Description
DEV EMULATOR PCB ADAPTOR
Manufacturer
Renesas Electronics America
Datasheet

Specifications of HS3802ECH62H

Accessory Type
User Interface Cable
For Use With/related Products
H8/3802
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
To our customers,
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Renesas Electronics website:
Old Company Name in Catalogs and Other Documents
http://www.renesas.com
April 1
Renesas Electronics Corporation
st
, 2010

Related parts for HS3802ECH62H

HS3802ECH62H Summary of contents

Page 1

To our customers, Old Company Name in Catalogs and Other Documents st On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the ...

Page 2

All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm ...

Page 3

... H8/3802 Group FP-64E User System Interface Cable for E6000 Emulator User’s Manual H8/3802 HS3802ECH62HE Renesas Microcomputer Development Environment System H8 Family/H8/300L Super Low Power Series Rev.3.0 2003.12 ...

Page 4

Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may ...

Page 5

... Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products. User system interface cable (HS3802ECH62H) The user system or a host computer is not included in this definition. Purpose of the User System Interface Cable: This user system interface cable is for connecting the emulator station and user system ...

Page 6

LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in ...

Page 7

State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and ...

Page 8

READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL ...

Page 9

Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST not ...

Page 10

... Thank you for purchasing this user system interface cable (HS3802ECH62H) for the Renesas’s original microcomputer H8/3802, H8/38004 group. The HS3802ECH62H is a user system interface cable that connects an H8/3802, H8/38004 group E6000 emulator (HS3800EPI60H; hereinafter referred to as the emulator) to the IC socket for a FP-64E package for the H8/3802, H8/38004 group MCU on the user system ...

Page 11

Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 Connecting User System Interface Cable to Emulator Station .......................................... 3 2.1 2.2 Connecting User System Interface Cable to User System................................................. 5 2.2.1 Installing IC Socket.............................................................................................. 5 2.2.2 Soldering IC Socket ............................................................................................. 5 ...

Page 12

... Section 1 Configuration Use an IC149-064-175-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64E package IC socket on the user system. Figure 1 shows the configuration of the HS3802ECH62H user system interface cable for the FP-64E package. To emulator station Screws ( mm) with flat washers Figure 1 HS3802ECH62H User System Interface Cable ...

Page 13

... Table 1 lists the HS3802ECH62H components. Please make sure you have all of these components when unpacking. Table 1 HS3802ECH62H Components No. Component 1 Cable body 2 Cable head 3 IC socket 4 Socket cover 5 Screws ( mm) 6 Screws ( mm) 7 Documentation 2 Quantity Remarks 1 Flat cable 1 1 For the FP-64E package ...

Page 14

Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will ...

Page 15

Emulator station Figure 2 Connecting User System Interface Cable to Emulator Station 4 Cable body connector User system interface cable ...

Page 16

Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 ...

Page 17

Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-64E package on the user system with pin 1 on the user system interface cable head, and insert the ...

Page 18

Fasten the user system interface cable head to the IC socket for an FP-64E package on the user system with the four screws (M2 tightened a little at a time, alternating between screws on opposing corners. Take special care, such ...

Page 19

Fastening Cable Body Connect the cable body to the cable head. Cable body User system 8 Remove jig Cable head Figure 4 Fastening Cable Body Removing Push the remove jig ...

Page 20

Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-64E package (IC149-064-175-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that ...

Page 21

Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10 25.0 19.3 63.5 Unit: mm Tolerance: ±0.5 mm ...

Page 22

Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head User system Figure 7 Resulting Dimensions after Connecting User ...

Page 23

Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.29 N•m or less. If ...

Page 24

Screws ( mm) with flat washers User system Figure 8 Installing MCU to User System Socket cover MCU Pin 1 IC socket (IC149-064-175-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) 13 ...

Page 25

Section 4 Verifying Operation 1. When using the H8/3802 group E6000 emulator (HS3800EPI60H), turn on the emulator according to the procedures described in the H8/3802 Group E6000 Emulator User's Manual (HS3800EPI60HE). 2. Verify the user system interface cable connections by ...

Page 26

Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications HCU04 To E6000 emulator HCU04 R2 270 OSC1 OSC2 System clock oscillator Figure 9 System Clock Oscillator and Subclock ...

Page 27

Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount ...

Page 28

H8/3802 Group FP-64E User System Interface Cable For E6000 Emulator User's Manual Publication Date: Rev.3.00, December 19, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. 2003 ...

Page 29

User System Interface Cable for E6000 Emulator 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan H8/3802 Group FP-64E User’s Manual REJ10B0099-0300H ...

Related keywords