CDB5467U Cirrus Logic Inc, CDB5467U Datasheet - Page 35

BOARD EVAL FOR CS5467 ADC

CDB5467U

Manufacturer Part Number
CDB5467U
Description
BOARD EVAL FOR CS5467 ADC
Manufacturer
Cirrus Logic Inc
Type
A/Dr
Datasheets

Specifications of CDB5467U

Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
CS5467
Primary Attributes
Watt-Hour Meter
Secondary Attributes
Graphical User Interface, SPI™ & USB Interfaces
Product
Data Conversion Development Tools
Maximum Clock Frequency
4 MHz
Interface Type
USB
Supply Voltage (max)
5 V
Supply Voltage (min)
3.3 V
For Use With/related Products
CS5467
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1555
CDB-5467U
8.3.5 Mode Control (Modes)
DS714F1
IHPF2
23
15
Default = 0
VFIX
E1MODE[1:0]
E2MODE[1:0]
VHPF2:IHPF2
VHPF1:IHPF1
E3MODE[1:0]
E3MODE[1:0]
POS
AFC
7
-
-
E1MODE1
VHPF1
VFIX
22
14
6
Use internal RMS voltage reference instead of voltage input for average active power.
E1, E2, and E3 alternate output mode (when enabled by E2MODE).
E2 Output Mode
High-pass Filter Enable for Energy Channel 2
High-pass Filter Enable for Energy Channel 1
E3 Output Mode (with E1MODE disabled)
E3 Output Mode (with E1MODE enabled)
Positive Energy Only. Suppresses negative values in P1
Enables automatic line frequency measurement which sets Epsilon every time a new line
0 = Use voltage input.
1 = Use internal RMS voltage reference, VF
00 = E1, E2 = P1
01 = E1, E2 = S1 , S2
10 = E1, E2 = Q1
11 = E1, E2 = Q1
00 = Energy Sign
01 = Total Apparent Energy
10 = Not Used
11 = Enable E1MODE
00 = No Filter
01 = HPF on Current, PMF on Voltage
10 = HPF on Voltage, PMF on Current
11 = HPF on both Voltage and Current
00 = No Filter
01 = HPF on Current, PMF on Voltage
10 = HPF on Voltage, PMF on Current
11 = HPF on both Voltage and Current
00 = Total Reactive Energy (default)
01 = Power Fail Monitor
10 = Voltage1 Sign
11 = Total Apparent Energy
00 = Power Fail Monitor
01 = Energy Sign
10 = Not Used
11 = Not Used
is calculated, zero will be stored instead.
frequency measurement completes. Epsilon is used to control the gain of the 90 degree
phase shift integrator used in quadrature power calculations.
E1MODE0
IHPF1
Address: 16
21
13
5
-
AVG
AVG
WB
, Q2
, P2
, Q2
20
12
WB
AVG
4
-
-
-
AVG
E3MODE1
19
11
3
-
-
RMS .
E2MODE1
E3MODE0
18
10
2
-
AVG
and P2
E2MODE0
POS
AVG
17
9
1
-
. If a negative value
CS5467
VHPF2
AFC
16
8
0
-
35

Related parts for CDB5467U