CP2201EK Silicon Laboratories Inc, CP2201EK Datasheet - Page 45

KIT EVAL FOR CP2201 ETH CTRLR

CP2201EK

Manufacturer Part Number
CP2201EK
Description
KIT EVAL FOR CP2201 ETH CTRLR
Manufacturer
Silicon Laboratories Inc
Type
Controllers & Processorsr
Datasheets

Specifications of CP2201EK

Main Purpose
Interface, Ethernet Sensor
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
CP2200, CP2201
Primary Attributes
Temperature and Light Sensor
Secondary Attributes
Graphic User Interface
Interface Type
Ethernet
Product
Modules
Silicon Manufacturer
Silicon Labs
Silicon Core Number
CP2201
Silicon Family Name
CP220x
Kit Contents
CP2201 Evaluation Board, Power Adapter, CAT5e Ethernet Cable, CD-ROM, Quick-Start Guide
For Use With/related Products
CP2201
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
336-1316

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CP2201EK
Manufacturer:
SiliconL
Quantity:
8
10.5. Disabling Secondary Device Functions
The LED Drivers, weak pull-ups, and V
supply current for the V
the MOTEN and MUXEN pins are tied to ground, but will cause the address and data pins to float (causing
undefined device behavior and increased power consumption) if they are not externally driven or pulled to a
defined logic level using pull-up or pull-down resistors. The internal weak pull-ups should not be disabled unless all
digital pins are externally driven to a logic high or logic low state.
Bits 7–4: UNUSED. Read = 0000b, Write = don’t care.
Bit 3
Bit 2
Bit 1:
Bit 0:
R/W
Bit7
ACTEN: Activity LED Enable
0: Activity LED disabled.
1: Activity LED enabled.
LINKEN: Link LED Enable (Link/Activity LED on CP2201)
0: Link (Link/Activity) LED disabled.
1: Link (Link/Activity) LED enabled.
WEAKD: Weak Pull-up Disable
0: Weak pull-ups are enabled.
1: Weak pull-ups are disabled.
Reserved. Read = 0b; Must write 0b.
R/W
Bit6
Register 15. IOPWR: Port Input/Output Power Register
DD
Monitor is specified in Table 13 on page 42. Disabling weak pull-ups will save current if
R/W
Bit5
R/W
DD
Bit4
Monitor can be disabled to minimize power consumption. The typical
ACTEN
R/W
Bit3
Rev. 1.0
LINKEN
R/W
Bit2
WEAKD Reserved 00000000
R/W
Bit1
R/W
Bit0
CP2200/1
Reset Value
Address:
0x70
45

Related parts for CP2201EK