ATSTK600 Atmel, ATSTK600 Datasheet - Page 5

DEV KIT FOR AVR/AVR32

ATSTK600

Manufacturer Part Number
ATSTK600
Description
DEV KIT FOR AVR/AVR32
Manufacturer
Atmel
Series
AVR®r
Type
MCUr
Datasheets

Specifications of ATSTK600

Processor To Be Evaluated
AVR and AVR32
Data Bus Width
8 bit
Interface Type
RS-232, USB
Silicon Manufacturer
Atmel
Core Architecture
AVR
Core Sub-architecture
AVR UC3
Silicon Core Number
STK600
Silicon Family Name
AVR
Kit Contents
Board
Rohs Compliant
Yes
For Use With/related Products
Atmel AVR Devices
For Use With
ATSTK600-ATTINY10 - STK600-ATTINY10 SOCKET PACKAGE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Contents
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATSTK600
Manufacturer:
Atmel
Quantity:
135
Part Number:
ATSTK600-ATTINY10
Manufacturer:
Atmel
Quantity:
135
Part Number:
ATSTK600-DIP40
Manufacturer:
Atmel
Quantity:
135
Part Number:
ATSTK600-RC14
Manufacturer:
Atmel
Quantity:
135
Part Number:
ATSTK600-RC15
Manufacturer:
Atmel
Quantity:
135
Table 3-12. Command format.
Table 3-13. Answer format if command succeeded.
3.6 CMD_FIRMWARE_UPGRADE
Table 3-14. Command format.
Table 3-15. Answer format.
3.7 CMD_LOAD_RC_ID_TABLE
Field
Command ID
Address
Field
Answer ID
Status
Field
Command ID
Parameter ID
Field
Answer ID
Status
8133A-AVR-04/08
Size
1 byte
4 byte
Size
1 byte
1 byte
Size
1 byte
10 bytes
Size
1 byte
1 byte
For word-addressed memories (program flash), the Address parameter is the word
address.
If bit 31 is set, this indicates that the following read/write operation will be performed
on a memory that is larger than 64KBytes. This is an indication to STK600 that a load
extended address must be executed. See datasheet for devices with memories larger
than 64KBytes.
When the host is trying to connect to the programmer, it checks the firmware version.
A firmware upgrade is initiated if a newer version is available on the PC.
The STK600 can “reboot” into upgrade mode by using this command
If the status returned is STATUS_CMD_OK, the STK600 will disconnect and enter
upgrade mode.
This command sends the Routing Card boardID table to the STK600 FW. Each row in
this table holds first the RC_id, then the SC_id (allowed to use with that RC) and then
the MAX_VTG allowed for that routingcard.
The two first bytes of the table hold the revision of the table. MSB first.
Values
CMD_LOAD_ADDRESS
Values
CMD_LOAD_ADDRESS
STATUS_CMD_OK
Values
”fwupgrade”
Values
CMD_SET_PARAMETER
STATUS_CMD_OK or
STATUS_CMD_FAILED
CMD_FIRMWARE_UPGRADE
Description
Command id
The address, four bytes, MSB first
Description
Answer id
A status value indicating success
Description
Command id
String to enable upgrade mode
Description
Answer id
A status value indicating the result of the
operation
AVR079
5