ATSTK600 Atmel, ATSTK600 Datasheet - Page 7

DEV KIT FOR AVR/AVR32

ATSTK600

Manufacturer Part Number
ATSTK600
Description
DEV KIT FOR AVR/AVR32
Manufacturer
Atmel
Series
AVR®r
Type
MCUr
Datasheets

Specifications of ATSTK600

Processor To Be Evaluated
AVR and AVR32
Data Bus Width
8 bit
Interface Type
RS-232, USB
Silicon Manufacturer
Atmel
Core Architecture
AVR
Core Sub-architecture
AVR UC3
Silicon Core Number
STK600
Silicon Family Name
AVR
Kit Contents
Board
Rohs Compliant
Yes
For Use With/related Products
Atmel AVR Devices
For Use With
ATSTK600-ATTINY10 - STK600-ATTINY10 SOCKET PACKAGE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Contents
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATSTK600
Manufacturer:
Atmel
Quantity:
135
Part Number:
ATSTK600-ATTINY10
Manufacturer:
Atmel
Quantity:
135
Part Number:
ATSTK600-DIP40
Manufacturer:
Atmel
Quantity:
135
Part Number:
ATSTK600-RC14
Manufacturer:
Atmel
Quantity:
135
Part Number:
ATSTK600-RC15
Manufacturer:
Atmel
Quantity:
135
3.9 CMD_CHECK_TARGET_CONNECTION
Table 3-20. Command format.
Table 3-21. Answer format.
4 ISP Programming Commands
Field
Command ID
Field
Answer ID
Answer value
Status
8133A-AVR-04/08
Size
1 byte
Size
1 byte
1 byte
1 byte
This command runs a target connection check and returns the status of the target
connection.
The value is 6bits, where bit 0-2 indicates the status of the short circuit protection
system and bit 4-5 indicates if the ISP is connected correctly to the target system.
Bit 4-5 will only indicate correct target connection if the target is powered.
Bit 3 is “Don’t care”.
Table 3-22. bit descriptions.
The corresponding bit will be set ‘1’ to indicate an error.
That is, if a line is short circuited, if target is not detected or the plug is inserted with a
reverse orientation.
If the value 0x00 is returned it means the connection is ok.
The parameter should be checked before starting a programming sequence to check
if target connection is correct (bit 4-5).
It should also be checked after a programming sequence if the command failed, to
check if the operation failed because of a short circuit.
A short circuit can only be detected after the command Enter Progmode has been
issued, because the control circuits of the STK600 is isolated via switches when the
STK600 is in idle mode.
These commands handles FLASH, EEPROM, fuse bytes, lock bits, signature and
oscillator calibration programming in ISP mode.
Bit #
0
1
2
4
5
Values
CMD_CHECK_TARGET_CONNECTION
Values
CMD_LOAD_EC_ID_TABLE
STATUS_CMD_OK
Se table below.
Status
STATUS_CONN_FAIL_MOSI
STATUS_CONN_FAIL_RST
STATUS_CONN_FAIL_SCK
STATUS_ISP_READY
STATUS_TGT_REVERSE_INSERTED
Description
Answer id
Status of target connection
Description
Command id
AVR079
7

Related parts for ATSTK600