C8051F120DK Silicon Laboratories Inc, C8051F120DK Datasheet - Page 98

DEVKIT-F120/21/22/23/24/25/26/27

C8051F120DK

Manufacturer Part Number
C8051F120DK
Description
DEVKIT-F120/21/22/23/24/25/26/27
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheet

Specifications of C8051F120DK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F12x and C8051F13x
Interface Type
USB
Silicon Manufacturer
Silicon Labs
Core Architecture
8051
Silicon Core Number
C8051F120
Silicon Family Name
C8051F12x
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F120, 121, 122, 123, 124, 125, 126, 127
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1224

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F120DK
Manufacturer:
SiliconL
Quantity:
4
Part Number:
C8051F120DK
Manufacturer:
*
Quantity:
1
C8051F120/1/2/3/4/5/6/7
C8051F130/1/2/3
98
Bit7:
Bit6:
Bit5:
Bit4:
Bits3–1: AD2CM2–0: ADC2 Start of Conversion Mode Select.
Bit0:
SFR Page:
SFR Address:
AD2EN
R/W
Bit7
AD2EN: ADC2 Enable Bit.
0: ADC2 Disabled. ADC2 is in low-power shutdown.
1: ADC2 Enabled. ADC2 is active and ready for data conversions.
AD2TM: ADC2 Track Mode Bit.
0: Normal Track Mode: When ADC2 is enabled, tracking is continuous unless a conversion
is in process.
1: Low-power Track Mode: Tracking Defined by AD2CM2-0 bits (see below).
AD2INT: ADC2 Conversion Complete Interrupt Flag.
This flag must be cleared by software.
0: ADC2 has not completed a data conversion since the last time this flag was cleared.
1: ADC2 has completed a data conversion.
AD2BUSY: ADC2 Busy Bit.
Read:
0: ADC2 Conversion is complete or a conversion is not currently in progress. AD2INT is set
to logic 1 on the falling edge of AD2BUSY.
1: ADC2 Conversion is in progress.
Write:
0: No Effect.
1: Initiates ADC2 Conversion if AD2CM2-0 = 000b
AD2TM = 0:
000: ADC2 conversion initiated on every write of ‘1’ to AD2BUSY.
001: ADC2 conversion initiated on overflow of Timer 3.
010: ADC2 conversion initiated on rising edge of external CNVSTR2.
011: ADC2 conversion initiated on overflow of Timer 2.
1xx: ADC2 conversion initiated on write of ‘1’ to AD0BUSY (synchronized with ADC0 soft-
ware-commanded conversions).
AD2TM = 1:
000: Tracking initiated on write of ‘1’ to AD2BUSY for 3 SAR2 clocks, followed by conver-
sion.
001: Tracking initiated on overflow of Timer 3 for 3 SAR2 clocks, followed by conversion.
010: ADC2 tracks only when CNVSTR2 input is logic low; conversion starts on rising
CNVSTR2 edge.
011: Tracking initiated on overflow of Timer 2 for 3 SAR2 clocks, followed by conversion.
1xx: Tracking initiated on write of ‘1’ to AD0BUSY and lasts 3 SAR2 clocks, followed by con-
version.
AD2WINT: ADC2 Window Compare Interrupt Flag.
This bit must be cleared by software.
0: ADC2 Window Comparison Data match has not occurred since this flag was last cleared.
1: ADC2 Window Comparison Data match has occurred.
2
0xE8
AD2TM
R/W
Bit6
(bit addressable)
SFR Definition 7.4. ADC2CN: ADC2 Control
AD2INT AD2BUSY AD2CM2 AD2CM1
R/W
Bit5
R/W
Bit4
Rev. 1.4
R/W
Bit3
R/W
Bit2
AD2CM0
R/W
Bit1
AD2WINT 00000000
R/W
Bit0
Reset Value